This is a multicentric, single arm, prospective, stratified by breast density clinical investigation using Mammowave that is a device, which uses microwaves instead of ionizing radiation (X-ray)for breast lesions(BL) detection. Specifically, Mammowave employs a novel technique which generates images by processing very low power (<1 mW) microwaves. The exam takes few minutes per breast and is performed with the patient lying in a comfortable facing down position. Mammowave is safe to be used at any age, in any condition (pregnancy, specific illness) and for unlimited number of times.
The number of participants will be 500 (for all the sites). The Study will be composed of two phases: a preliminary phase to 'optimize the imaging algorithm for each apparatus installed at each centre', where 15 healthy volunteers in each centre will be examined by MammoWave. In the second phase, the remaining people will be enrolled (Breast Lesions pts will be about 70% of total) and examined by MammoWave by the clinical investigator, and results will be compared with the effective diagnosis already obtained by standard clinical methods. BL includes malignant lesions (BC) and benign lesions, and may be palpable or non-palpable lesions. BL includes also isolated clustered microcalcifications.
At the end of the study, in each centre the clinical investigators will compare MammoWave output against the radiologist study output obtained using conventional exams.
In addition, at the end of the study, the MammoWave output will be centrally reviewed in blind by an independent radiologist in order to confirm the data and confirm centrally the comparisons performed locally. The primary goal of the clinical study is to assess Mammowave's ability in BL detection and differentiation.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single arm | Other | All patients perform standard breast screening and also MammoWave exam. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Clinical investigation device class IIa not marked CE | Device | Patients should perform MammoWave exam. A short visit should be performed and during this visit a qualitative differentiation would be performed between patients with high density breast, and patients with low density breast. After the patients will be ready for the MammoWave exam. The exam will be composed of two phases: the data acquisition and the data processing. During the acquisition that should takes about 10 minutes the patients would be lying in a prone position, on a bed which is part of the MammoWave. The upper part of MammoWave has a container cup shape, which contains the breast, which also has the function of separate it from the internal parts of the device. After patient is on the bed and MammoWave would start to perform the acquisition. Once the acquisition is completed, the data will be processed through an imaging algorithm, which is integrated in the device. The final output will be composed by one or more images, plus one or more parameters describing the images. |
| Measure | Description | Time Frame |
|---|---|---|
| MammoWave sensitivity (number of 'true positive' results) | MammoWave sensitivity (number of 'true positive' results) compared to Reference Standard | During the procedure |
| Measure | Description | Time Frame |
|---|---|---|
| MammoWave specificity and sensitivity (against Reference Standard) | MammoWave specificity and sensitivity (against Reference Standard like Mammography, MRI and/or Echography) | During the baseline |
| Percentage of correct BL localization in terms of quadrant (against Reference Standard) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Women in order to performe breast screening
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Istituto Clinico Humanitas | Rozzano | Milano | 20089 | Italy | ||
| Azienda Ospedaliera Universitaria S. Martino Di Genova |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001943 | Breast Neoplasms |
| ID | Term |
|---|---|
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D001941 | Breast Diseases |
| D012871 | Skin Diseases |
Not provided
Not provided
Clinical investigation with Medical Device class IIa
Not provided
Not provided
Not provided
Not provided
|
Percentage of correct BL localization in terms of quadrant comparing to Reference Standard like Mammography, MRI and/or Echography |
| During the baseline |
| Absolute and rate agreement between different evaluator (i.e. local radiologist versus central) | Absolute and rate agreement between different evaluator local radiologist versus central, in order to avoid mistakes in the MammoWave output. | Through study completion, an average of 1 year |
| Sensitivity for each breast density group | Sensitivity of MammoWave according to different types of breast density groups | During the baseline |
| Sensitivity for patients which had recent mammography | Sensitivity for patients which had performed recently mammography exam. | During the baseline |
| Patient satisfaction questionnaire. | Patient satisfaction questionnaire output according to their experience performing MammoWave test based on 12 questions: n° 2 "Multiple Choice questions" YES, NO, explain (with open-ended text area) regarding:
| During the baseline |
| Genova |
| 16132 |
| Italy |
| Hospital Virgen de la Salud | Toledo | 16132 | Spain |
| D017437 |
| Skin and Connective Tissue Diseases |