Systematic continuous glucose monitoring (CGM) is commonly provided as a treatment option to patients with diabetes in ambulatory care settings yet is rarely provided during hospitalization. CGM of inpatients has the potential to be the care delivery innovation that is feasible, cost effective and can improve glucose control, especially by reducing hypoglycemic events. Studies of CGM use in the ICU setting have been found to be helpful for reducing hypoglycemia in some studies while less so in others, however, these studies were performed with earlier generation glucose monitoring devices(5). ICU studies have confirmed accuracy of CGM measurements compared with capillary glucose even in settings with use of vasopressors and large-volume resuscitation. A limited number of studies have evaluated glycemic outcomes in the inpatient non-ICU setting. Studies of non-ICU patients (6-10) are limited by very small sample size, short study duration, and use of older CGM devices. There is, therefore, a critical need to systematically investigate the use of CGM in the inpatient care of patients with diabetes mellitus who are receiving care in a hospital setting that is typical of inpatient care.
AIM
1) Test the health impact of CGM of inpatients as defined by rates of hypo- and hyperglycemia and the derivative of time in appropriate glucose range. Forty (40) patients will be randomized 1:1 into one of two conditions. In the treatment condition, patients will receive a Dexcom Gen6 device and the clinical staff (i.e., nursing and medical staff assigned to the patient's care) will be trained to use readings from the Dexcom Gen6 for the management of the patient's glucose levels below 100. In the control condition, patients will receive a Dexcom Gen6 device, but the clinical staff (i.e., nursing and medical staff assigned to the patient's care) will not have access to the readings and will provide usual care (four glucose checks per 24 hours and use of insulin or other diabetic agent ordered by the admitting and rounding providers to determine glucose management).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control Group | Active Comparator | Control Group subjects will wear the CGM device during their hospitalization, up to 10 days, but glucose readings will NOT be continuously monitored. Control Group subjects will have their glucose management guided by routine standard of care finger sticks. The readings from the CGM device are recorded and reviewed retrospectively, but not used for glucose management during the hospital stay. |
|
| Treatment Group | Experimental | Treatment Group subjects will wear the CGM device during their hospitalization, up to 10 days, and glucose readings WILL be continuously monitored. Treatment Group subjects will have their glucose management guided by readings from the CGM device and standard of care finger sticks. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dexcom Generation 6 CGM (Dexcom Gen6) device | Device | Standing orders for blood sugars less than 100 will allow for administration of glucose replacement in the intervention group based on Dexcom Gen6 readings. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Hypoglycemia Events during hospitalization | Dexcom Gen6 readings | Up to 10 days |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Hyperglycemia Events during hospitalization | Dexcom Gen6 readings | Up to 10 days |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Tresa McNeal, MD | Baylor Scott & White Medical Center - Temple | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Baylor Scott & White Medical Center - Temple | Temple | Texas | 76508 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 9539990 | Background | Levetan CS, Passaro M, Jablonski K, Kass M, Ratner RE. Unrecognized diabetes among hospitalized patients. Diabetes Care. 1998 Feb;21(2):246-9. doi: 10.2337/diacare.21.2.246. | |
| 24170754 | Background | Mendez CE, Mok KT, Ata A, Tanenberg RJ, Calles-Escandon J, Umpierrez GE. Increased glycemic variability is independently associated with length of stay and mortality in noncritically ill hospitalized patients. Diabetes Care. 2013 Dec;36(12):4091-7. doi: 10.2337/dc12-2430. Epub 2013 Oct 29. |
Not provided
Not provided
No plan to share individual participant data
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot | Yes | No | No | Study Protocol | Nov 15, 2022 | Dec 24, 2022 | Prot_001.pdf |
Not provided
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| ID | Term |
|---|---|
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
| D004700 | Endocrine System Diseases |
Not provided
Not provided
Dexcom Generation 6 CGM (Dexcom Gen6) device
Not provided
Not provided
Not provided
Not provided
|
| 19502209 | Background | Curkendall SM, Natoli JL, Alexander CM, Nathanson BH, Haidar T, Dubois RW. Economic and clinical impact of inpatient diabetic hypoglycemia. Endocr Pract. 2009 May-Jun;15(4):302-12. doi: 10.4158/EP08343.OR. |
| 23466973 | Background | Rubin DJ, Golden SH. Hypoglycemia in non-critically ill, hospitalized patients with diabetes: evaluation, prevention, and management. Hosp Pract (1995). 2013 Feb;41(1):109-16. doi: 10.3810/hp.2013.02.1016. |
| 28098809 | Background | van Steen SC, Rijkenberg S, Limpens J, van der Voort PH, Hermanides J, DeVries JH. The Clinical Benefits and Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients-A Systematic Scoping Review. Sensors (Basel). 2017 Jan 14;17(1):146. doi: 10.3390/s17010146. |
| 26330394 | Background | Gomez AM, Umpierrez GE, Munoz OM, Herrera F, Rubio C, Aschner P, Buendia R. Continuous Glucose Monitoring Versus Capillary Point-of-Care Testing for Inpatient Glycemic Control in Type 2 Diabetes Patients Hospitalized in the General Ward and Treated With a Basal Bolus Insulin Regimen. J Diabetes Sci Technol. 2015 Aug 31;10(2):325-9. doi: 10.1177/1932296815602905. |
| 25927357 | Background | Schaupp L, Donsa K, Neubauer KM, Mader JK, Aberer F, Holl B, Spat S, Augustin T, Beck P, Pieber TR, Plank J. Taking a Closer Look--Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy. Diabetes Technol Ther. 2015 Sep;17(9):611-8. doi: 10.1089/dia.2014.0343. Epub 2015 Apr 30. |
| 28290224 | Background | Levitt DL, Silver KD, Spanakis EK. Inpatient Continuous Glucose Monitoring and Glycemic Outcomes. J Diabetes Sci Technol. 2017 Sep;11(5):1028-1035. doi: 10.1177/1932296817698499. Epub 2017 Mar 14. |
| 27543272 | Background | Levitt DL, Silver KD, Spanakis EK. Mitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus. J Diabetes Sci Technol. 2017 Mar;11(2):440-441. doi: 10.1177/1932296816664538. Epub 2016 Aug 20. No abstract available. |
| 29237288 | Background | Spanakis EK, Levitt DL, Siddiqui T, Singh LG, Pinault L, Sorkin J, Umpierrez GE, Fink JC. The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System. J Diabetes Sci Technol. 2018 Jan;12(1):20-25. doi: 10.1177/1932296817748964. Epub 2017 Dec 13. |
| 17927832 | Background | Bradley C, Plowright R, Stewart J, Valentine J, Witthaus E. The Diabetes Treatment Satisfaction Questionnaire change version (DTSQc) evaluated in insulin glargine trials shows greater responsiveness to improvements than the original DTSQ. Health Qual Life Outcomes. 2007 Oct 10;5:57. doi: 10.1186/1477-7525-5-57. |
| 19664226 | Background | Damschroder LJ, Aron DC, Keith RE, Kirsh SR, Alexander JA, Lowery JC. Fostering implementation of health services research findings into practice: a consolidated framework for advancing implementation science. Implement Sci. 2009 Aug 7;4:50. doi: 10.1186/1748-5908-4-50. |