The impression is a necessary step for the orthodontic diagnosis. Digital impression has recently been introduced by means of intraoral optical scanners. To date, few studies have compared the conventional alginate impression with the digital impression with intraoral scanners. These studies have shown that digital impression could have some advantages in terms of satisfaction and less discomfort for the pediatric patient. Only one study is randomized and has analyzed patients between 10 and 17 years of age. There are, therefore, no randomized trials for patients under 10 years of age.
The objective of the study is to compare the conventional alginate impression with the digital impression of both dental arches in orthodontic patients between 6 and 10 years of age with a randomized crossover design. In particular, the preference, comfort, impression taking time and other subjective aspects will be analyzed. This is a monocentric, controlled, superiority, randomized, crossover, open study.
Inclusion criteria:
- Orthodontic patients between 6 and 10 years of age.
Exclusion criteria:
As for the calculation of the sample size, this has been done by considering a null hypothesis for a proportion of 50% in the preference between the two treatments and an alternative hypothesis of 80%. For alpha set at 0.05, a power of 80% and a dropout rate of 10%, 24 patients are required.
Descriptive statistics will be performed for all variables (frequency and percentage for qualitative variables and mean and standard deviation for quantitative variables). For the primary endpoint variable, impression procedure preference, the test will be performed for one proportion and the 95% confidence interval will be calculated using the Clopper-Pearson method.
With regard to the secondary endpoint variables, duration of the procedure, comfort, pain, gag reflex, breathing difficulty, the 2 procedures will be compared with the t-test for paired data.
An Intention-To-Treat analysis will be performed. In case more than 5 deviations from the protocol will occur, a sensitivity analysis will also be performed per protocol.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Digital Impression Technique | Experimental | Impression with an intraoral scanner (TRIOS 3, 3Shape, Denmark) |
|
| Conventional Impression Technique | Active Comparator | Conventional impression with alginate (Orthoprint, Zhermack) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Digital Impression Technique | Other | Digital impressions of both arches will be taken by using an intraoral scanner (Trios 3, 3Shape, Denmark) by adhering to the scanning pattern recommended by the company for routine diagnosis and recording. |
| Measure | Description | Time Frame |
|---|---|---|
| Patient's preference for either digital or conventional impression techniques | The patient will be asked "If you had to take another impression which one of the 2 impression techniques would you prefer?" The patient will mark on a sheet of paper which one of the 2 impression techniques he/she prefers. | 30 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Comfort during impression taking | VAS (Visual Analogue Scale) from 0 to 10 with 0 corresponding to "very uncomfortable" and 10 corresponding to "maximum comfort" | 15 minutes |
| Pain during impression taking |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| SOD Odontostomatologia | Florence | 50127 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 36891891 | Derived | Bosoni C, Nieri M, Franceschi D, Souki BQ, Franchi L, Giuntini V. Comparison between digital and conventional impression techniques in children on preference, time and comfort: A crossover randomized controlled trial. Orthod Craniofac Res. 2023 Nov;26(4):585-590. doi: 10.1111/ocr.12648. Epub 2023 Mar 20. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Conventional Impression Technique | Other | Conventional Impression Technique of both arches will be taken with alginate (Orthoprint, Zhermack) on conventional stainless steel impression trays. |
|
VAS (Visual Analogue Scale) from 0 to 10 with 0 corresponding to "no pain" and 10 corresponding to "very painful"
| 15 minutes |
| Gag reflex during impression taking | VAS (Visual Analogue Scale) from 0 to 10 with 0 corresponding to "no gag reflex" and 10 corresponding to "vomiting" | 15 minutes |
| Respiratory difficulty | VAS (Visual Analogue Scale) from 0 to 10 with 0 corresponding to "no respiratory difficulty" and 10 corresponding to "maximum respiratory difficulty" | 15 minutes |
| Duration of the impression procedure | Time recorded in minutes | 15 minutes |