Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Subacromial injection is considered one of the best treatments for patients with subacromial impingement syndrome. The subacromial bursa is located between the deltoid muscle and the supraspinatus tendon. It facilitates the gliding of the humeral head through the undersurface of the acromion. If the bursa is thickened, the patient may experience pain when he/she tries to raise the arm. In patients with subacromial impingement due to a thickened subacromial bursa, the physician can precisely inject the medication into the bursa using ultrasound guidance. Use of ultrasound guidance has been proven to yield a better effect of pain relief than the technique using guidance. A previous study found that even using ultrasound guidance to deliver medication, there were still many patients suffering from initial treatment failure or recurrence after the first successful injection. Because the pathophysiological mechanism of subacromial impingement is complexed, the proximal biceps tendon may be involved but is often ignored. Recently, the investigators published a randomized controlled trial comparing the effect of dual-target injection (proximal biceps tendon and subacromial bursa) with the standard subacromial injection in patients with subacromial impingement syndrome, and found that the dual target approach was safe and had a longer effective duration than the standard subacromial injection. In this regard, the investigators will conduct a longitudinal follow-up study to examine the long-term effectiveness of the dual-target corticosteroid injection for subacromial impingement syndrome.
Introduction:
Subacromial injection is considered one of the best treatments for patients with subacromial impingement syndrome. The subacromial bursa is located between the deltoid muscle and the supraspinatus tendon. It facilitates the gliding of the humeral head through the undersurface of the acromion. If the bursa is thickened, the patient may experience pain when he/she tries to raise the arm. In patients with subacromial impingement due to a thickened subacromial bursa, the physician can precisely inject the medication into the bursa using ultrasound guidance. Use of ultrasound guidance has been proven to yield a better effect of pain relief than the technique using guidance. A previous study found that even using ultrasound guidance to deliver medication, there were still many patients suffering from initial treatment failure or recurrence after the first successful injection. Because the pathophysiological mechanism of subacromial impingement is complexed, the proximal biceps tendon may be involved but is often ignored. Recently, the investigators published a randomized controlled trial comparing the effect of dual-target injection (proximal biceps tendon and subacromial bursa) with the standard subacromial injection in patients with subacromial impingement syndrome, and found that the dual target approach was safe and had a longer effective duration than the standard subacromial injection. In this regard, the investigators will conduct a longitudinal follow-up study to examine the long-term effectiveness of the dual-target corticosteroid injection for subacromial impingement syndrome.
Material and methods:
Participants: adult patients (>20 year old) with shoulder impingement syndrome Inclusion criteria: shoulder pain>3 weeks; no contraindication for local injection; Visual analogue scale of pain>4 The healthy volunteers are defined as no shoulder pain, and are only for the assessment of the inter-rater and intra-rater reliability of the ultrasound evaluation, without intervention
Participant number: 210 (150 with subacromial impingement, and 60 of healthy subjects) Exclusion criteria: systemic rheumatologic disease, Ankylosing spondylitis, malignancy, major trauma or recent injections on the affected shoulder
Study design:
The aims of this study is (1) set up the inter-rater and intra-rater reliability of the ultrasound evaluation in patients with subacromial impingement and healthy subjects (2) longitudinal follow up the therapeutic effect of dual-target injection to subacromial bursa and biceps tendon sheath only in patients with subacromial impingement
Detail of the intervention Single arm experiment: ultrasound guided injection into the subacromial bursa and biceps tendon sheath in patients with subacromial impingements, with 40 mg triamcinolone acetonide plus 3 mL of lidocaine
Outcome measurement:
physical examination(bicipital groove compression test, Speed's test, Yergason's test, empty can test, Neer's impingement test, Hawkins-Kennedy impingement test, painful arc test), range of motion as the baseline information. Visual analogue scale of pain, shoulder pain and disability index (SPADI), shoulder sonography (gray-scale/elastography)
Statistical analysis:
Continuous variables
Categorical variables
(1) Chi-square test (2) Fisher exact test: sparse data
Multivariate analysis:
Keywords: ultrasonography, corticosteroid, subacromial impingement syndrome, shoulder pain, longitudinal follow-up
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Dual-Target injection | Experimental | Corticosteroid injection into the subacromial bursa and biceps tendon |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dual-target injection | Procedure | Intervention procedure: corticosteroid injection into the subacromial bursa and biceps tendon Device for guidance: high-resolution ultrasound Drug: 40 mg triamcinolone acetonide (a kind of corticosteroid) + 3 mL of lidocaine (the medication will be mixed with 40 mg triamcinolone acetonide) |
| Measure | Description | Time Frame |
|---|---|---|
| Change in shoulder pain and disability index (SPADI) | Shoulder pain and disability index (SPADI). The SPADI contains 13 items that assess two domains; a 5-item subscale that measures pain and an 8-item subscale that measures disability. | Within 1 year after injection |
| Measure | Description | Time Frame |
|---|---|---|
| Change in visual analogue scale of pain | The Visual Analogue Scale (VAS) consists of a straight line with the endpoints defining extreme limits such as 'no pain at all' and 'pain as bad as it could be' . The patient is asked to mark his pain level on the line between the two endpoints. | Within 1 year after injection |
Not provided
Inclusion Criteria:
Exclusion Criteria:
The healthy volunteers are defined as no shoulder pain, and are only for the assessment of the inter-rater and intra-rater reliability of the ultrasound evaluation, without intervention.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Ke-Vin Chang, MD | Contact | +886-23717101 | 5309 | pattap@pchome.com.tw |
| Name | Affiliation | Role |
|---|---|---|
| Ke-Vin Chang | National Taiwan University Hospital Beihu Branch | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| National Taiwan University Hospital, Bei-Hu branch | Recruiting | Taipei | 108 | Taiwan |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 40593369 | Derived | Wu WT, Lin CY, Shu YC, Chen LR, Ozcakar L, Chang KV. Predictive value of subacromial motion metrics for the effectiveness of ultrasound-guided dual-target injection: a longitudinal follow-up cohort trial. Insights Imaging. 2025 Jul 1;16(1):145. doi: 10.1186/s13244-025-01989-5. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D019534 | Shoulder Impingement Syndrome |
| ID | Term |
|---|---|
| D007592 | Joint Diseases |
| D009140 | Musculoskeletal Diseases |
| D000070599 | Shoulder Injuries |
| D014947 | Wounds and Injuries |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Doppler image of the rotator cuff tendons |
Doppler image of the rotator cuff tendons is to evaluate the vascularity, before and after treatment. |
| Within 1 year after injection |
| Elasticity (strain ratio) of the rotator cuff tendons | Elasticity (strain ratio) is calculated for the target by selecting a region of interest (ROI) over the rotator interval and rotator cuff tendon, with a corresponding ROI of the adjacent reference tissue. The Using machine inherent software, the strain ratio value is displayed on a static image. The elasticity is measured before and after treatment. | Within 1 year after injection |
| Dynamic ultrasound evaluation | The dynamic ultrasound evaluation is motion analysis regarding the related shoulder structures during shoulder abduction. The dynamic movement movie will be analyzed by software. The motion analysis is measured before and after treatment. | Within 1 year after injection |