Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Prospective non randomized study of the feasibility of the insertion of Rocamed urethral device by hand manipulation, i.e., without use of cystoscopy, sonography or fluoroscopy. Patients with an acute urinary retention treated by Foley catheterization in the Emergency department have a few days later a trial of Foley removal in the ambulatory unit of the Urology department. In case of failure of the Foley removal trial, i.e., recurrence of urinary retention, patients will be proposed either the insertion of a new Foley or insertion of the urethral device. After signature of an informed consent, insertion of the urethral device will be performed after instillation in the urethra of a local anesthetic gel. Device insertion success rate and complications will be studied. The device will be left in place for one month. Tolerance and complications during the month with the device in place will be studied. At one month the device will be removed: the ease of retrieval of the device and complications will be studied. Patient and doctor satisfaction with the urethral device will be compared to patient and doctor satisfaction with the Foley.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Prospective non randomised feasibility study | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Exime is the name of the single use temporary prostatic stent used instead of the Foley catheter | Device | Insertion after instillation of a local lubricant anesthetic gel in the urethra like for Foley insertion. Calibration of the urethral meatus with a 22F Bougie. Insertion of the Bougie until abutment against the posterior wall of the bulbous urethra just below the striated sphincter. Note depth of abutment on the scale of the Bougie. Retrieve the Bougie and glide the device to the same depth until abutment against the posterior wall of the bulbous urethra. At this stage the stent is correctly positioned. Stent release: unlock the Luer connection between pusher tube and stylet . Retrieve pusher tube, stylet and flattener tube. Control of correct positioning: ask patient to stand up to verify the absence of any urine leak. Ask patient to void immediately to control clear urine output. |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of patients in whom the device will be inserted only by hand manipulation | Day 0 |
| Measure | Description | Time Frame |
|---|---|---|
| Patient tolerance during device insertion: analogic visual scale 0-10 (0 : no pain / 10 : worst pain imaginable) | Day 0 (Day of device insertion) | |
| Patient tolerance during one month: analogic visual scale 0-10 (0 : excellent tolerance / 10 : intolerable) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Service d'Urologie Hôpital Lyon Sud, Hospices Civils de Lyon | Pierre-Bénite | 69495 | France |
Not provided
| ID | Term |
|---|---|
| D016055 | Urinary Retention |
| ID | Term |
|---|---|
| D014555 | Urination Disorders |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| 1 Month |
| Flowmetry with device in place ml/sec | Day 0 (Day of device insertion) |
| Patient tolerance during retrieval of the device : analogic visual scale 0-10 (0 : no pain / 10 : worst pain imaginable) | 1 month |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |