Not provided
Not provided
Not provided
Not provided
Expired IRB approval 12/12/2020
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of the LEGO®Bricks MRI project is to study a new play-based tool for use in children preparing to undergo MRI and evaluate its ability to reduce the need for anesthesia.
A randomized study design will be employed in the experimental "Child Life" (CL) group, in regard to which Child Life intervention patients will have. Age matched controls will be found retrospectively, and will be patients of the same age, undergoing their first non-contrast brain MRI with no Child Life intervention.
Patients in the CL group will be prepped by a Certified Child Life Specialist with the use of one of the following 2 tools, to be randomly selected:
Diagnostic imaging is frequently utilized in modern medical practice, and various imaging modalities are routinely utilized in the care of pediatric patients. Magnetic resonance imaging (MRI) is an advanced imaging modality that is utilized to evaluate many conditions in pediatric patients. MRI is frequently favored over other imaging modalities in pediatrics since it allows for high-quality cross sectional imaging without the use of potentially harmful ionizing radiation, to which children are more sensitive than adults. However, MRI quality is highly dependent on patients' ability to hold still and follow instructions, which is often challenging in pediatric patients. Young and uncooperative children often require anesthesia to successfully complete MRI. Anesthesia can often be avoided with the assistance of Certified Child Life Specialists, who use techniques to reduce patient anxiety and improve children's ability to follow instructions during MRI. For example, children may visit the MRI unit or a simulator prior to the examination to contextualize the procedure1-3. Preparation, in the form of play, has been proven to reduce anxiety in children prior to scans and invasive medical procedures. Children who are prepared for medical procedures experience less fear and anxiety and will have better long term adjustment to medical challenges (Koller, 2008).
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Child life group with LEGO bricks | Experimental | Patients in this group will be prepped by a Certified Child Life Specialist with the use of LEGO bricks model MR |
|
| Control group | No Intervention | Age matched controls will be found retrospectively, and will be patients of the same age, undergoing their first non-contrast brain MRI with no Child Life intervention. | |
| Child life group with Mock MRI tube | Experimental | Patients in this group will be prepped by a Certified Child Life Specialist with the use of a Mock MRI tube |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| LEGO Bricks MRI | Other | LEGO Bricks model MRI (A model of the MRI machine and adjacent control room made out of LEGO bricks) will be used by the child life specialist to prepare the child for MRI |
| Measure | Description | Time Frame |
|---|---|---|
| Number of participants who need anesthesia - Comparing CL groups ((1) LEGO Bricks model MRI and (2) mock MRI tube groups) and Control group | Monitor whether or not the child needs anesthesia to successfully complete MRI exam | Up to 90 minutes (duration of MRI exam) |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Anxiety Scores -Comparing CL groups (1) LEGO Bricks model MRI and (2) mock MRI tube -- Control group will not have Anxiety Scores available, and will not be assessed on this secondary outcome measure. | Anxiety score will be measured by response to a series of questions using an anxiety self rating scale where for each questions particpants need to decide if Not at all applies (mark 1) Somewhat (mark 2) Moderately (mark 3) Very much (mark 4). |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mark Liszewski, MD | Montefiore Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Montefiore Medical Center | The Bronx | New York | 10467 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17517937 | Background | Saleh RS, Patel S, Lee MH, Boechat MI, Ratib O, Saraiva CR, Finn JP. Contrast-enhanced MR angiography of the chest and abdomen with use of controlled apnea in children. Radiology. 2007 Jun;243(3):837-46. doi: 10.1148/radiol.2433060155. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001008 | Anxiety Disorders |
| ID | Term |
|---|---|
| D001523 | Mental Disorders |
Not provided
Not provided
There will be two experimental groups including the LEGO Bricks group, and the Mock MRI tube group, as well as a retrospective age matched control group.
Not provided
Not provided
Not provided
| Mock MRI tube | Other | Mock MRI tube will be used by the child life specialist to prepare the child for MRI |
|
| At time of enrollment (Baseline) and at the end of MRI exam, which typically ranges from 15-90 minutes |
| Change in quality of MRI image- Comparing CL groups ((1) LEGO Bricks model MRI and (2) mock MRI tube groups) and Control group using image quality and motion artifact grading scale | This will be assessed by blinded attending radiologist/ resident radiologist. The above mentioned grading scale scores motion artifact and image quality on a 1 to 4 and 0 to 3 scales as follows: Image quality: 1 (excellent images, with very high confidence in diagnostic content), 2 (good images, with confidence in diagnostic content), 3 (fair images, with reservations about diagnostic content), 4 (poor nondiagnostic image), Motion artifact: 0 (no motion artifact)
| 1-2 weeks (average time to get MRI results) |
| Change in duration of MRI exam-Comparing time stamp (ending time of exam minus beginning time of exam) of MRI in CL groups ((1) LEGO Bricks model MRI and (2) mock MRI tube groups) and Control group | Total length of time from beginning to end of MRI scan will be recorded and compared between groups, by subtracting the start time of the exam from the end time of the exam. | At the end of MRI exam, which typically ranges from 15-90 minutes |