A novel dynamic random-dot stereopsis test that included motion + disparity (MD), motion (M), and disparity (D), in which the disparity cues range from 200 to 1200 arc-seconds was used. The characteristics of preoperative dynamic stereopsis in 83 intermittent exotropia patients and its associations with clinical features were analysed, and the prognosis was followed up on the 1st day and 2nd, 6th and 12nd months postoperatively.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intermittent exotropia group | Intermittent exotropia group |
| |
| Normal group | Normal group |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| The dynamic stereopsis test | Diagnostic Test | The characteristics of preoperative dynamic stereopsis in 83 intermittent exotropia patients and its associations with clinical features were analysed, and the prognosis was followed up on the 1st day and 2nd, 6th and 12nd months postoperatively. |
| Measure | Description | Time Frame |
|---|---|---|
| The mean reciprocal value of stereopsis | The mean reciprocal value of stereopsis on the 1st day | 1st day |
| The mean reciprocal value of stereopsis | The mean reciprocal value of stereopsis on the 2nd month | 2nd month |
| The mean reciprocal value of stereopsis | The mean reciprocal value of stereopsis on the 6th month | 6th month |
| The mean reciprocal value of stereopsis | The mean reciprocal value of stereopsis on the 6th month | 12th month |
Not provided
Not provided
Inclusion Criteria:
X(T) groups were as follows:
Normal group were as follows:
Exclusion Criteria:
X(T) groups were as follows:
Normal group were as follows:
Not provided
Not provided
A total of 83 cases X(T) patients and 50 normal subjects were enrolled in the study.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Zhongshan Opthalmic Center | Guangzhou | Guangdong | 510000 | China |
A novel dynamic random-dot stereopsis test that included motion + disparity (MD), motion (M), and disparity (D), in which the disparity cues range from 200 to 1200 arc-seconds was used. The characteristics of preoperative dynamic stereopsis in 83 intermittent exotropia patients and its associations with clinical features were analysed, and the prognosis was followed up on the 1st day and 2nd, 6th and 12nd months postoperatively.