The Neuroguard IEP System is a 3-in-1 carotid stent delivery system consisting of an angioplasty balloon, an integrated embolic protection device and a nitinol self-expanding stent loaded over the balloon and constrained by an outer sheath. The PERFORMANCE I study is a multi-center, prospective, single arm open label study to evaluate the safety and feasibility of the Neuroguard IEP System for the treatment of carotid artery stenosis. The primary endpoint will be the proportion of patients with Major Adverse Events (MAE) reported within 30 days from the index procedure.
The primary objective of the PERFORMANCE I study is to evaluate the safety and feasibility of the Neuroguard IEP Carotid Stent System when used in patients with clinically significant carotid artery stenosis requiring revascularization.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Carotid artery stenting with Neuroguard IEP System | Experimental | To evaluate the safety and feasibility of the Neuroguard IEP System when used in patients with clinically significant carotid artery stenosis requiring revascularization. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Neuroguard® IEP 3-in-1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System) | Device | The Neuroguard® IEP 3-in-1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection is indicated for improving the carotid luminal diameter in patients with clinically significant carotid artery stenosis and for the simultaneous capture and removal of embolic material during angioplasty and stenting. |
| Measure | Description | Time Frame |
|---|---|---|
| Major Adverse Event (MAE) | Death, stroke, myocardial infarction (MI) within 30 days of the index procedure | 30 days |
Not provided
Not provided
Inclusion Criteria:
Male and non-breastfeeding female subjects whose age is ≥18 years.
Patient is willing and capable of complying with all study protocol requirements, including specified follow-up period and can be contacted by telephone.
Patient is willing to provide written informed consent prior to enrollment in study.
Females of childbearing potential must have documented negative pregnancy test within 7 days of the Index procedure.
Patient is either:
7. Patient has a target lesion located at the carotid bifurcation and/or proximal internal carotid artery (ICA).
8. Patient has a single de novo or restenotic (post carotid endarterectomy [CEA]) target lesion or severe tandem lesions close enough that can be covered by a single Neuroguard stent.
9. Target lesion reference vessel diameter between 4.0 and 7.0 mm. 10. Distal vessel diameter at the site of filter deployment between 4.0 mm and 7.0 mm.
11. Sufficient landing zone in the cervical internal carotid artery distal to the lesion to allow for the safe and successful deployment of the primary embolic protection filter (commercially available) and the Neuroguard integrated embolic protection filter.
Exclusion Criteria
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Alberto Cremonesi, MD | Maria Cecelia Hospital Cotignola | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Sankt Gertrauden-Krankenhaus GmbH | Berlin | 10713 | Germany | |||
| Cardiovascular Centre Frankfurt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 36229946 | Background | Langhoff R, Petrov I, Kedev S, Milosevic Z, Schmidt A, Scheinert D, Schofer J, Sievert H, Sedgewick G, Saylors E, Sachar R, Cremonesi A, Micari A. PERFORMANCE 1 study: Novel carotid stent system with integrated post-dilation balloon and embolic protection device. Catheter Cardiovasc Interv. 2022 Nov;100(6):1090-1099. doi: 10.1002/ccd.30410. Epub 2022 Oct 13. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Frankfurt |
| Germany |
| Medizinisches Versorgungszentrum | Hamburg | 22527 | Germany |
| Universitätsklinikum Leipzig | Leipzig | 04103 | Germany |
| Maria Cecelia Hospital | Cotignola | 48033 | Italy |
| Università Frederico II | Naples | Italy |
| ID | Term |
|---|---|
| D016893 | Carotid Stenosis |
| ID | Term |
|---|---|
| D002340 | Carotid Artery Diseases |
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided