Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Dr François Lintz | UNKNOWN |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The automated TALAS measurement tool, working with the Cone Beam 3D scanner under load, provides a reproducible measurement of the Foot Ankle Offset (FAO). It is possible to determine an average value and the standard deviation of FAO in the relevant population. And to differentiate significantly the populations with a neutral alignment, varus or valgus.
The analysis of the alignment of the foot is fundamental in the management of pathologies of the foot and ankle. The advent of 3D imaging under load (Scanner Cone Beam), less radiant and more precise, requires the development and evaluation of new measurement tools.
The automated TALAS measurement tool, working with the Cone Beam 3D scanner under load, provides a reproducible measurement of the Foot Ankle Offset (FAO). It is possible to determine an average value and the standard deviation of FAO in the relevant population. And to differentiate significantly the populations with a neutral alignment, varus or valgus.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Ankel surgery group | Adult patients for which a Cone Beam under load is prescribed for a preoperative assessment of a foot or ankle surgery or for a follow-up consultation. |
| |
| control foot group | Adult patients for which a Cone Beam under load is prescribed for a preoperative assessment of a foot or ankle surgery or for a follow-up consultation. Will be retained only results of normal aligment FAO |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3D Imaging FAO measurement and Clinical evaluation of the hindfoot alignment | Diagnostic Test | The Cone Beam under load is used for the diagnosis and monitoring of the foot and ankle. It has a CE marking for this purpose. The images obtained by the Cone Beam under load (Ped Cat) will be analysed using the TALAS mathematical algorithm tool to measure the FAO. The internal software of the Cone Beam under load will also be used to obtain a "radiographic" image corresponding to a 2D projection on which the tibio-calcaneal angle can be measured. |
| Measure | Description | Time Frame |
|---|---|---|
| FAO value measured | - FAO value measured using the TALAS tool on data collected by the Cone Beam under load (PedCat). For the descriptive study of the distribution within the different populations (varus/normal/valgus), the first measurement carried out will be represented. | 1 day |
| FAO Reliability | - reliability of FAO measurement by the TALAS tools (Intraclass correlation coefficient) | 1 day |
| FAO sensitivity-specificiy | - Couples (Sensitivity - Specificity) of the FAO ROC curve allowing the morphological classification of the patients (Varus, Valgus or Normal) | 1 day |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Adult's patients for which a Cone Beam under load is prescribed for a preoperative assessment of a foot or ankle surgery or for a follow-up consultation.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Clinique de L'Union | Saint-Jean | 31240 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|