This registry is designed to quantify embolic debris capture rate in patients at low surgical risk treated with the Sentinel System during TAVI.
The SENTINEL-LIR Study is a multicenter, prospective registry to observe rate and type of debris capture in subjects at low surgical risk undergoing TAVI to demonstrate the positive effects of the use of the Sentinel System. Histopathology of captured debris from the Sentinel System will be analyzed.
The primary objective is to determine the presence or absence of particles of 7 discreet tissue types: acute thrombus (with or without associated tissue/foreign material), organizing thrombus, valve tissue, arterial wall/necrotic core, calcification, foreign material, and myocardium. Morphometric assessment of the debris (sizes >150 m, >500 m, and >1,000 m).
Patients will be screened for inclusion and exclusion criteria and documents which will have been reviewed and approved by the local Ethics Committee or regulatory authority prior to undergoing any study related exams or procedures.
Fifty (50) subjects will be enrolled in the study from an estimated 6 different sites.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Sentinel Device | Device | Sentinel Device used during TAVI in a Low Risk Patient |
| Measure | Description | Time Frame |
|---|---|---|
| The SENTINEL-LIR Study | To determine the incidence and type of debris capture in SENTINEL devices deployed during TAVI in patients at low surgical risk | 12 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
The study population is comprised of subjects with severe native aortic valve stenosis who meet the commercially approved indications for TAVI and comply with the inclusion/exclusion criteria described below.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Aloke V Finn, MD | CVPath Institute | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Columbia University Medical Center | New York | New York | 10032 | United States | ||
| Carolinas Medical Center |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30590554 | Background | Seeger J, Kapadia SR, Kodali S, Linke A, Wohrle J, Haussig S, Makkar R, Mehran R, Rottbauer W, Leon M. Rate of peri-procedural stroke observed with cerebral embolic protection during transcatheter aortic valve replacement: a patient-level propensity-matched analysis. Eur Heart J. 2019 May 1;40(17):1334-1340. doi: 10.1093/eurheartj/ehy847. | |
| 29976363 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001024 | Aortic Valve Stenosis |
| ID | Term |
|---|---|
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
We will collect debris that have been captured in the Sentinel filter and perform pathology on those specimens
| Charlotte |
| North Carolina |
| 28203 |
| United States |
| Cleveland Clinic | Cleveland | Ohio | 44195 | United States |
| UPMC Pinnacle | Wormleysburg | Pennsylvania | 17043 | United States |
| Schmidt T, Leon MB, Mehran R, Kuck KH, Alu MC, Braumann RE, Kodali S, Kapadia SR, Linke A, Makkar R, Naber C, Romero ME, Virmani R, Frerker C. Debris Heterogeneity Across Different Valve Types Captured by a Cerebral Protection System During Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv. 2018 Jul 9;11(13):1262-1273. doi: 10.1016/j.jcin.2018.03.001. |
| 29397361 | Background | Lazar RM, Pavol MA, Bormann T, Dwyer MG, Kraemer C, White R, Zivadinov R, Wertheimer JC, Thone-Otto A, Ravdin LD, Naugle R, Mechanic-Hamilton D, Garmoe WS, Stringer AY, Bender HA, Kapadia SR, Kodali S, Ghanem A, Linke A, Mehran R, Virmani R, Nazif T, Parhizgar A, Leon MB. Neurocognition and Cerebral Lesion Burden in High-Risk Patients Before Undergoing Transcatheter Aortic Valve Replacement: Insights From the SENTINEL Trial. JACC Cardiovasc Interv. 2018 Feb 26;11(4):384-392. doi: 10.1016/j.jcin.2017.10.041. Epub 2018 Feb 1. |
| 27815101 | Background | Kapadia SR, Kodali S, Makkar R, Mehran R, Lazar RM, Zivadinov R, Dwyer MG, Jilaihawi H, Virmani R, Anwaruddin S, Thourani VH, Nazif T, Mangner N, Woitek F, Krishnaswamy A, Mick S, Chakravarty T, Nakamura M, McCabe JM, Satler L, Zajarias A, Szeto WY, Svensson L, Alu MC, White RM, Kraemer C, Parhizgar A, Leon MB, Linke A; SENTINEL Trial Investigators. Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement. J Am Coll Cardiol. 2017 Jan 31;69(4):367-377. doi: 10.1016/j.jacc.2016.10.023. Epub 2016 Nov 1. |
| 35272475 | Derived | Kawakami R, Gada H, Rinaldi MJ, Nazif TM, Leon MB, Kapadia S, Krishnaswamy A, Sakamoto A, Sato Y, Mori M, Kawai K, Cornelissen A, Park JE, Ghosh SKB, Abebe BG, Romero M, Virmani R, Finn AV. Characterization of Cerebral Embolic Capture Using the SENTINEL Device During Transcatheter Aortic Valve Implantation in Low to Intermediate-Risk Patients: The SENTINEL-LIR Study. Circ Cardiovasc Interv. 2022 Apr;15(4):e011358. doi: 10.1161/CIRCINTERVENTIONS.121.011358. Epub 2022 Mar 11. No abstract available. |
| D014694 |
| Ventricular Outflow Obstruction |