A prospective, randomized, controlled post-market clinical investigation that will enroll pediatric subjects requiring laceration repair. The investigation population will consist of 30 subjects fulfilling the eligibility criteria for the clinical investigation. The subjects will be randomly assigned at a 1:1 ratio to either the Zip 4 Surgical Skin Closure Device group or the Standard of Care sutures group.
The commercial use of the Zip device has demonstrated applicability and acceptance in many medical specialties, including laceration closure in the Emergency Department setting. However, while clinical studies have demonstrated quantitative performance benefits of the device in orthopedic, dermatology, cardiac and cardiology specialties, no quantitative studies have been conducted in the Emergency Department setting with the device with which emergency medicine physicians may make quantitative, informed treatment choices. The Sponsor (ZipLine Medical) and the study doctor (investigator) have furthermore identified the pediatric patient population presenting for laceration repair in the Emergency Department as a group that may uniquely benefit from the use of the Zip device.
Standard care for wounds of this type require cleaning the wound, anesthetizing the wound and closing the wound with sutures that typically require subsequent removal at a later date. The Zip device is non-invasive and therefore requires no injected anesthesia or sedation for wound closure. In addition, the referenced clinical studies have demonstrated at least a 3 times speed advantage over sutures. The Zip device ease of use and consistency of outcomes enables less skilled or experienced caregivers to perform fast, efficient and excellent wound closure, which can improve department and staff efficiency, patient throughput and overall patient satisfaction. Finally, the Zip device may be removed by the patient or parent at home, eliminating a return-to-clinic visit for removal.
ZipLine Medical believes that the demonstrated benefits of the Zip device will be more pronounced with the specified pediatric population due to reduced procedure time, elimination of injected anesthesia and elimination of a return visit for suture removal. ZipLine Medical believes that this will reduce fear and anxiety in pediatric patients. Furthermore, ZipLine Medical believes that the Zip device can improve Emergency Department efficiency and patient throughput, reduce overall healthcare cost and improve overall patient (and parent) satisfaction.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Zip Skin Closure Device | Active Comparator | The device is a class IIa device as per Annex II of the MDD 93/42EEC, as amended by Directive 2007/47/EEC. A CE-mark was affixed in 2014. The Zip device adheres to the skin adjacent to an incision or laceration by use of pressure-sensitive skin adhesives. A combination of acrylic and hydrocolloid adhesives is used to provide a skin-friendly environment while providing the necessary tack to maintain skin adhesion during a maximum wear time of 14 days. In addition to the pressure-sensitive adhesives, the device's closure and force distribution components are made up of polyurethane monofilm, polyethylene tape, polyester and nylon. |
|
| Standard of Care Sutures | Active Comparator | Conventional sutures used for laceration repair |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Zip Skin Closure Device | Device | The device is a CE-marked, single use, sterile medical device that is designed to provide closure speed superior to sutures, while resulting in a suture-like cosmetic outcome. It adheres to the skin adjacent to an incision or laceration by use of pressure-sensitive skin adhesives. |
| Measure | Description | Time Frame |
|---|---|---|
| Mean difference in time to wound closure of the Zip 4 Surgical Skin Closure Device in comparison to conventional sutures used in a pediatric population presenting for laceration repair. | These include total treatment time and duration of period starting from the preparation of procedure until protective wound dressing is applied, and including whether or not anesthesia and/or sedation was used when comparing the Zip 4 Surgical Skin Closure Device and the standard of care closure suturing | Intra operative |
| Measure | Description | Time Frame |
|---|---|---|
| Difference in Wound Evaluation Score (WES) | A Wound Evaluation Score will be documented by an independent reviewer of photos taken at Day 0 and compared to 10 Day and 30 Day to evaluate the satisfaction and outcomes of the Zip 4 Surgical Skin Closure Device in comparison to conventional sutures used in a pediatric population presenting for laceration repair. The WES evaluates six clinical variables including incision edges, contour irregularity, width, edge inversion, inflammation and overall cosmesis. A score of 6 is considered optimal, while a score of < or =5 suboptimal. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Eric Storne | Contact | 408.684.0747 | estorne@ziplinemedical.com |
| Name | Affiliation | Role |
|---|---|---|
| Uri Balla, MD | Kaplan Medical Center, Eehovot Israel | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Kaplan Medical Center | Recruiting | Rehovot | Israel |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot | Yes | No | No | Study Protocol | Jul 13, 2018 | Oct 8, 2019 | Prot_000.pdf |
Not provided
A prospective, randomized, controlled post-market clinical investigation that will enroll pediatric subjects requiring laceration repair. The investigation population will consist of 30 pediatric subjects fulfilling the eligibility criteria for the clinical investigation. The subjects will be randomly assigned at a 1:1 ratio to either the Zip 4 Surgical Skin Closure Device group or the Standard of Care sutures group.
Not provided
Not provided
Not provided
Not provided
|
| 10 days and 30 days post laceration repair |
| Satisfaction of Rate of Wound Healing of Laceration Repair:satisfaction rating | Parents of patients will document the rate of wound healing satisfaction in subject post-treatment. The satisfaction rating for the Zip 4 Surgical Skin Closure Device will be compared to conventional sutures used in a pediatric population for laceration repair. The questionnaire will contain questions where the parent either will mark the most correct answer or rate on a line between 0 (Very Satisfied) to 100 (Very Dissatisfied) mm. | 30 days post laceration repair |
| Pain Level for Wound Healing of Laceration Repair: visual analog scale (VAS) | Parents of patients will document the level of pain the patient experiences in connection to the Zip 4 Surgical Skin Closure Device and conventional sutures application and removal used in a pediatric population for laceration repair by a visual analog scale (VAS) 0 (No Pain) -100 (Worst Pain) mm | Day 0 and 10 days post laceration repair |
| Safety by Adverse Events reported that relate to the study device | The incidence and severity of adverse events associated with the Zip 4 Surgical Skin Closure Device and Standard of Care closure sutures. | Intra operative through the end of the study at 30 days post laceration repair |