In this study, the investigators compare timely acquirement and effectiveness of 12-lead ECG using patchy-type wireless versus using defibrillator which contain ECG examination function in ambulance.
The purpose of this study is to determine the difference of timely acquirement of 12-lead ECG using two different systems and the difference of efficiency of ECG examination in ambulance between two groups.
The participants in this simulation study were divided randomly into 2 groups :
Group A is performing an ECG examination on mock patient using defibrillator which contained 12-lead ECG checking function. And take a 15 minutes wash out period. After the wash out period, group A subject performing an ECG examination using patchy-type wireless device.
Group B subject is performing an ECG examination on mock patient using patchy-type wireless device first, and take a 15 minutes wash out period. After the wash out period, group B performing an ECG examination using defibrillator which contain 12-lead ECG function.
Both group's ECG examination is performing in the ambulance.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group A : defibrillator ECG to patchy-type ECG | Active Comparator | Group A subject will performing ECG examination to a mock patient in the ambulance. First ECG performance will be using defibrillator which contain 12-lead ECG checking function. And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using patchy-type wireless device. when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect. |
|
| Group B : patchy-type ECG to defibrillator ECG | Experimental | Group B subject will performing ECG examination to a mock patient in the ambulance. First ECG performance will be using patchy-type wireless device. And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using defibrillator which contain 12-lead ECG checking function. when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| patchy-type wireless ECG | Device | This device consists of a single patchy and save the ECG result as a Potable Document Format. Also can transfer to hospital using wifi-network. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Time from 12-lead ECG device application starting to sending ECG result to hospital. | comparison of interval from the start of 12-lead ECG device application to complete of ECG result sending | through study completion, an average of 2 month |
| Measure | Description | Time Frame |
|---|---|---|
| Usability of patchy-type wireless ECG device. | System Usability Scale survey of patchy-type wireless ECG device | survey collecting through study completion an average of 2 month |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| tearim kim, doctoral | samsumg medical center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Samsung Medical Center | Seoul | Gangnam | 06351 | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 36099010 | Derived | Yoo S, Chang H, Kim T, Yoon H, Hwang SY, Shin TG, Sim MS, Jo IJ, Choi JH, Cha WC. Intervention in the Timeliness of Two Electrocardiography Types for Patients in the Emergency Department With Chest Pain: Randomized Controlled Trial. Interact J Med Res. 2022 Sep 13;11(2):e36335. doi: 10.2196/36335. | |
| 33792550 | Derived |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002637 | Chest Pain |
| ID | Term |
|---|---|
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| defibrillator ECG | Device | This device is essential equipment in ambulance. For 12-lead ECG examination the connector need to replace for specific cable. |
|
| Yoon S, Kim T, Roh T, Chang H, Hwang SY, Yoon H, Shin TG, Sim MS, Jo IJ, Cha WC. Twelve-Lead Electrocardiogram Acquisition With a Patchy-Type Wireless Device in Ambulance Transport: Simulation-Based Randomized Controlled Trial. JMIR Mhealth Uhealth. 2021 Apr 1;9(4):e24142. doi: 10.2196/24142. |