Since Gruntzig successfully performed percutaneous coronary balloon angioplasty in 1977, percutaneous coronary intervention has developed rapidly. From bare metal stents to drug-eluting stents (DES), the symptoms and prognosis of patients with coronary heart disease (CHD) have been greatly improved. Although DES has reduced the probability of in-stent restenosis (ISR) and thrombosis compared with BMS since its clinical application, it can not completely solve this problem. Even if the new generation of DES requires revascularization, the incidence of ISR is still as high as 5%-10%. DES treatment is associated with delayed endothelial healing, late acquired poor stent adherence and new atherosclerosis, which lead to late ISR and thrombosis. In addition, DES is still not ideal for the treatment of small vessel disease, diffuse long lesion and bifurcation lesion. Therefore, drug coated balloon (DCB) has attracted people's attention. Balloon-loaded antiproliferative drugs can fully release the drugs to the vascular wall during balloon dilation, which can inhibit the restenosis process from the beginning of injury, and show good efficacy and safety in some specific lesions. Many clinical studies have shown that DCB has good efficacy and safety in some specific lesions (ISR, small vessel disease, bifurcation disease, in situ lesion). Especially in the treatment of ISR, researchers believe that its efficacy is not inferior to DES, and it has the advantage of non-metal residues.
Quantitative flow ratio (QFR) is the second generation FFR detection method based on angiographic images. The diagnostic accuracy of QFR 0.80 for myocardial ischemic stenosis was 92.7%. Compared with QCA, the positive predictive value and negative predictive value of QFR were also significantly better than those of QCA. The latest FAVOR II results also confirm that QFR is more sensitive and specific in diagnosing myocardial ischemia caused by coronary artery stenosis than QCA, and confirm the feasibility of using QFR online in catheter lab to evaluate the functional significance of coronary artery critical lesions. However, there is no report on the treatment of de novo lesions in patients with coronary heart disease by DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation.
The current study is designed as a multicenter, randomized and prospective study aiming to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation. Based on previous study, the incidence rate of target lesion failure is 5%-10% in patients with CHD undergoing DES implantation. And in the investigators study the expected incidence rate of target lesion failure is up to 5.0 % in patients with CHD after treatment with DCB. Moreover, the investigators estimated 10% loss follow-up of these patients in each arm. As a result, a total of 220 patients with CHD were required, and with 110 patients per group as a ratio of 1:1 randomization.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| drug coated balloon | Experimental | A total of 110 patients are assigned to drug coated balloon treated group after randomization schedule. |
|
| drug eluted stent implantation | No Intervention | A total of 110 patients are assigned to drug eluted stent treated group after randomization schedule. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| drug coated balloon | Device | Balloon/vessel diameter ratio 0.8-1.0, 8-12 ATM (atmosphere), lasting for >30 seconds |
|
| Measure | Description | Time Frame |
|---|---|---|
| The incidence rate of late lumen loss after percutaneous coronary intervention in patients with CHD | The incidence rate of late lumen loss between DCB treated group and DES treated group evaluated by quantitative coronary analysis in patients with CHD | Follow-up coronary angiography at 12 months after the procedure |
| Measure | Description | Time Frame |
|---|---|---|
| The incidence rate of device-related ischemic events | The incidence rate of device-related ischemic events including cardiovascular death, target vessel related myocardial infarction and ischemia-driven revascularization between DCB treated group and DES treated group | Clinical follow up at 30 days, 6, 9 and 12 months after the procedure |
Not provided
Inclusion Criteria:
●Meet the diagnostic criteria for stable angina pectoris, unstable angina pectoris and acute myocardial infarction and QFR<0.8 of target lesion
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Fei Ye, MD | Contact | +86 13327823900 | doctor_ye@126.com | |
| Xiangqi Wu, MD | Contact | +86 15250997876 | 15250997876@163.com |
| Name | Affiliation | Role |
|---|---|---|
| Fei Ye, MD | Nanjing First Hospital, Nanjing Medical University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Nanjing First Hospital | Nanjing | Jiangsu | 210006 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31401071 | Background | de la Torre Hernandez JM, Garcia Camarero T, Lozano Ruiz-Poveda F, Urbano-Carrillo CA, Sanchez Perez I, Cano-Garcia M, Saez R, Andres Morist A, Molina E, Pinar E, Torres A, Lezcano EJ, Gutierrez H, Arnold RJ, Zueco J. Angiography and Optical Coherence Tomography Assessment of the Drug-Coated Balloon ESSENTIAL for the Treatment of In-Stent Restenosis. Cardiovasc Revasc Med. 2020 Apr;21(4):508-513. doi: 10.1016/j.carrev.2019.07.021. Epub 2019 Jul 23. | |
| 31204115 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| ID | Term |
|---|---|
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| The incidence rate of patient-related ischemic events |
The incidence rate of patient-related ischemic events including all myocardial infarction , any revascularization and all-cause death between DCB treated group and DES treated group |
| Clinical follow up at 30 days, 6, 9 and 12 months after the operation |
| Background |
| Rissanen TT, Uskela S, Eranen J, Mantyla P, Olli A, Romppanen H, Siljander A, Pietila M, Minkkinen MJ, Tervo J, Karkkainen JM; DEBUT trial investigators. Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial. Lancet. 2019 Jul 20;394(10194):230-239. doi: 10.1016/S0140-6736(19)31126-2. Epub 2019 Jun 13. |
| 10027810 | Background | Bech GJ, Pijls NH, De Bruyne B, Peels KH, Michels HR, Bonnier HJ, Koolen JJ. Usefulness of fractional flow reserve to predict clinical outcome after balloon angioplasty. Circulation. 1999 Feb 23;99(7):883-8. doi: 10.1161/01.cir.99.7.883. |
| 29101020 | Background | Xu B, Tu S, Qiao S, Qu X, Chen Y, Yang J, Guo L, Sun Z, Li Z, Tian F, Fang W, Chen J, Li W, Guan C, Holm NR, Wijns W, Hu S. Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis. J Am Coll Cardiol. 2017 Dec 26;70(25):3077-3087. doi: 10.1016/j.jacc.2017.10.035. Epub 2017 Oct 31. |