The aim of this prospective randomised study was to shed more light on the issue by comparing the capacity of long plaster casts (above-elbow, LC) and short plaster casts (below-elbow, SC) to maintain the reduction of extra-articular distal radius fractures with dorsal displacement (2R3A2.2, according to the AO/OTA classification). The initial hypothesis was that the short cast would be equally as effective as the long cast in treating this type of fracture. The secondary objective of the study was to determine whether or not there is a direct correlation between radiological parameters and functional outcomes in such patients.
Distal radial fractures are common traumatic injuries, but their management remains controversial, Hence, we conducted a two-arm, parallel-group, prospective randomised trial to compare the capacity of long casts (above-elbow) and short casts (below-elbow) to maintain the reduction of extra-articular distal radius fractures with dorsal displacement (AO/OTA classification: 2R3A2.2). Eligible patients with AO/OTA 2R3A2.2 fractures treated with closed reduction and cast immobilization were randomized to the long cast group or to the short cast group. Baseline radiological parameters, radial inclination (RI), radial height (RH), ulnar variance (UV) and palmar tilt (PT) were taken, and compared with clinical (DASH, Mayo Wrist and Mayo Elbow) and radiological scores taken at 7-10 days, 4 weeks and 12 weeks. Furthermore, to evaluate correlations between radiological parameters and functional outcomes, patients were divided into two groups according to whether or not their radiological parameters at Follow-ups 2 and 3 were acceptable, i.e. within the range 11-12 mm for RH, 16°-28° for IR, -4-+2 mm for UV, and 0°-22° for PT.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Long plaster casts for type AO 2R3A2.2 | Active Comparator | Closed reduction of the fracture and immobilization with long plaster casts (above-elbow, Long plaster casts). |
|
| Short plaster casts for type AO 2R3A2.2 | Active Comparator | Closed reduction of the fracture and immobilization with short plaster casts (below-elbow, Short plaster casts) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| plaster cast | Device | Closed Reduction of Fracture and Application of Plaster Cast |
|
| Measure | Description | Time Frame |
|---|---|---|
| To measure the maintenance of fracture reduction according to radial inclination (Long plaster casts Vs Short plaster casts) | Radial inclination: angle of the distal radial surface with respect to a line perpendicular to the shaft, a normal 16° - 18° | compared at baseline, at 7-10 days, at 4 weeks and at 12 weeks |
| To measure the maintenance of fracture reduction according to radial height (Long plaster casts Vs Short plaster casts) | Radial height: distance between two parallel lines drawn perpendicular to the long axis of the radial shaft, one from the tip of the radial styloid and the other from the ulnar corner of the lunate fossa, normal 11-12 mm | compared at baseline, at 7-10 days, at 4 weeks and at 12 weeks |
| To measure the maintenance of fracture reduction according to ulnar variance (Long plaster casts Vs Short plaster casts) | Ulnar variance: refers to the relative lengths of the distal articular surfaces of the radius and ulna, normal -4-+2 mm | compared at baseline, at 7-10 days, at 4 weeks and at 12 weeks |
| To measure the maintenance of fracture reduction according to palmar tilt (Long plaster casts Vs Short plaster casts) | Palmar tilt: can be measured by obtaining the angle of intersection between a line drawn tangentially across the most distal points of the radial articular surface and a perpendicular to the midshaft of the radius, normal 0°-22° | compared at baseline, at 7-10 days, at 4 weeks and at 12 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation RX parameters Vs functional outcomes | To determine whether or not there is a direct correlation between radiological parameters and functional outcomes in conservatively treated patients for extra-articular distal radius fractures with dorsal displacement. The following will be used for the clinical evaluation: DASH, Mayo Wrist and Mayo Elbow scores. | twelve weeks |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gaetano Caruso, MD | Azienda Ospedaliero Universitaria di Ferrara | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Azienda Ospedaliero Universitaria di Ferrara | Ferrara | 44124 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31888682 | Derived | Caruso G, Tonon F, Gildone A, Andreotti M, Altavilla R, Valentini A, Valpiani G, Massari L. Below-elbow or above-elbow cast for conservative treatment of extra-articular distal radius fractures with dorsal displacement: a prospective randomized trial. J Orthop Surg Res. 2019 Dec 30;14(1):477. doi: 10.1186/s13018-019-1530-1. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D011885 | Radius Fractures |
| D000092503 | Wrist Fractures |
| ID | Term |
|---|---|
| D005543 | Forearm Injuries |
| D001134 | Arm Injuries |
| D014947 | Wounds and Injuries |
| D050723 | Fractures, Bone |
Not provided
Not provided
| ID | Term |
|---|---|
| D002370 | Casts, Surgical |
| ID | Term |
|---|---|
| D016267 | External Fixators |
| D009984 | Orthopedic Fixation Devices |
| D009983 | Orthopedic Equipment |
| D013523 | Surgical Equipment |
Not provided
Not provided
two-arm, parallel-group, prospective randomised trial
Not provided
Not provided
randomised trial
| D014954 |
| Wrist Injuries |
| D004864 |
| Equipment and Supplies |
| D053831 | Surgical Fixation Devices |