Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Objective: The primary objective is to investigate whether there is a difference in the number of hip dislocations following primary total hip arthroplasty (THA), using the posterolateral approach, with a DM cup compared to a unipolar cup in elderly patients 1 year after surgery.
Study design: Prospective multi-center nation wide, single blinded RCT nested in the LROI.
Study population: Patients ≥ 70 years old, undergoing an elective primary cemented THA.
Rationale: Dislocation is the leading reason for early revision surgery. To address the problem of dislocation, the dual-mobility (DM) cup was developed in France in the 1970's. This cup should provide more stability and biomechanically reduce the risk of dislocation. In the Netherlands, most DM cups are placed in specific patients, e.g. with cognitive impairment and for revisions due to recurrent dislocations. Despite the increased and, in some countries, broad use of DM cups, high quality evidence of their (cost)effectiveness is lacking. This study aims to perform a trial to fill this gap in knowledge. Much of the information needed to judge the effectiveness of DM cups is already incorporated in the Dutch Arthroplasty Register (LROI). This register lends itself perfectly for a nested RCT towards this aim.
Objective: The primary objective is to investigate whether there is a difference in the number of hip dislocations following primary total hip arthroplasty (THA), using the posterolateral approach, with a DM cup compared to a unipolar cup in elderly patients 1 year after surgery. The secondary objectives are: to investigate whether there is a difference in the number of revisions; to investigate what the cost-effectiveness and cost-utility is of a DM cup compared to a unipolar cup at 1 year follow-up; to investigate whether there is a difference in the number of hip dislocations and revisions between a DM cup and a unipolar cup 2 years after surgery; to investigate whether there is a difference in patient reported outcomes between a DM cup compared to a unipolar cup 1 and 2 years after surgery; to compare the number of hip dislocations, revisions and PROM data between patients in the randomized DM group and patients in an observational cohort DM group. Finally, long-term survival of DM and unipolar cups will be evaluated based on revision and mortality data registered in the LROI.
Study design: Prospective multi-center nation wide, single blinded RCT nested in the LROI.
Study population: Patients ≥ 70 years old, undergoing an elective primary cemented THA.
Intervention (if applicable): The intervention group receives a THA with a dual mobility cup, the control group receives a THA with a unipolar cup.
Main study parameters/endpoints: Primary: The number of dislocations. Secondary: costs, patient reported outcomes and implant survival.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness: In addition to the benefits from regular care, the primary hip arthroplasty procedure, patients might benefit from randomization to receiving a DM cup. DM cups are designed to reduce the risk of hip dislocation, compared to a unipolar cup. Patients may undergo more thorough follow-up than non-study patients and may benefit from this increased surveillance compared with regular care. The only burden associated with study participation is the time needed to complete the cost questionnaires (all other outcomes are part of standard care).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| unipolar cup | Active Comparator | 550 patients will receive a total hip arthroplasty with a unipolar cup. |
|
| Dual Mobility cup | Active Comparator | 550 patients will receive a total hip arthroplasty with a dual mobility cup. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Unipolar cup | Procedure | Cemented unipolar acetabulum cup for primary THA |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Number of dislocations | The total number of dislocations, regardless of type of treatment (i.e. closed repositioning or revision). | 1 year postoperative |
| Measure | Description | Time Frame |
|---|---|---|
| Number of revision surgeries | Revision surgery of any component for any reason | 1 year postoperative |
| cost-effectiveness questionnaire | An economic evaluation will be performed from the societal perspective, for dislocation and Quality Adjusted Life Years (QALYs). Prevailing guidelines of Zorginstituut Nederland will be observed. All costs and consequences relevant to THA, hip dislocation and hip revision will be taken into account. To compare costs between groups, confidence intervals around the mean differences in costs at one year after THA will estimated using the bias-corrected and accelerated bootstrap method. |
Not provided
Inclusion Criteria:
Exclusion Criteria
Patients unable to complete PROMs
Patients with dementia, epilepsy*, spasticity*, mental retardation or alcoholism. (If dementia or mental retardation is not already mentioned in the medical chart, this can be determined by doctors opinion.)
Patients not eligible for either a unipolar or a DM cup
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Loes van Beers, MSc | Contact | +31205993653 | l.w.a.h.vanbeers@olvg.nl | |
| Nienke Willigenburg, PhD | Contact | +31205992415 | n.w.willigenburg@olvg.nl |
| Name | Affiliation | Role |
|---|---|---|
| Rudolf Poolman, MD, PhD | OLVG, Amsterdam, the Netherlands | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| OLVG | Recruiting | Amsterdam | 1091 AC | Netherlands |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32746668 | Derived | Van Beers LWAH, Van Der Wal BCH, Van Loon TG, Moojen DJF, Van Wier MF, Klaassen AD, Willigenburg NW, Poolman RW; Collaborator group. Study protocol: Effectiveness of dual-mobility cups compared with uni-polar cups for preventing dislocation after primary total hip arthroplasty in elderly patients - design of a randomized controlled trial nested in the Dutch Arthroplasty Registry. Acta Orthop. 2020 Oct;91(5):514-519. doi: 10.1080/17453674.2020.1798658. Epub 2020 Aug 4. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D015207 | Osteoarthritis, Hip |
| ID | Term |
|---|---|
| D010003 | Osteoarthritis |
| D001168 | Arthritis |
| D007592 | Joint Diseases |
| D009140 | Musculoskeletal Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Dual mobility cup |
| Procedure |
Cemented dual mobility acetabulum cup for primary THA |
|
| 1 year postoperative |
| Number of dislocations | Total number of dislocations | 2 years postoperative |
| Patient Reported Outcomes on physical functioning | Difference in patient reported outcomes on physical functioning following primary THA with a DM cup compared to a unipolar cup, measured with the Hip disability and Osteoarthritis Outcome Score Physical Short form (HOOS-PS). Interval level scores from 0 (no difficulty) to 100 (extreme difficulty). | 1 and 2 years postoperative |
| Patient Reported Outcomes on pain | Difference in patient reported outcomes on pain, following primary THA with a DM cup compared to a unipolar cup, measured with the Numeric Ratin Scale (NRS) for pain in rest and during weight bearing. 0 means no pain, 10 means the most extreme pain. | 1 and 2 years postoperative |
| Patient Reported Outcomes on quality of life | Difference in patient reported outcomes quality of life, following primary THA with a DM cup compared to a unipolar cup, measured with the EuroQol 5 Dimensions (EQ-5D). A higher score means a worse quality of life, a lower score means a better quality of life. For the visual analogue scale (part of the EQ-5D), the lowest means the worst an the highest score means the best health score. | 1 and 2 years postoperative |
| Implant survival | Long-term implant survival based on LROI revision and mortality data. | 5 - 10 years postoperative |
| D012216 |
| Rheumatic Diseases |