The decision of emergency reperfusion of a suspected acute coronary artery occlusion by means of percutaneous coronary intervention or intravenous thrombolytics depends on the presence of a certain amount of ST-segment elevation in the electrocardiogram (ECG) as recommended by international guidelines. However, recommended ST-segment elevation cut-off values for acute coronary occlusion diagnosis are highly insensitive, and their evidence base is weak. The objective of this study is to test the accuracy of various electrocardiographic patterns (including, but not limited to, ST-segment elevation) for the diagnosis of acute coronary occlusion. This information can serve to offer an accuracy profile for various ECG findings and enable clinicians to define the ECG probability of an acute coronary occlusion according to these ECG findings and clinical picture, which in turn would provide a significant improvement in the care for patients who present to the hospital with possible coronary occlusion. The primary analysis will be designed as a single-center, retrospective case-control study.
In this retrospective, single-center, case-control study the investigators will seek to compare the diagnostic accuracy of various ECG criteria to identify acute coronary occlusion (ACO). The investigators will scan the charts of the patients presenting to emergency department with a clinical picture suggestive of acute coronary syndrome in the specified time period. Patients without any admission ECG will be excluded. Patients who had a final diagnosis of myocardial infarction (MI) with or without subsequent coronary intervention will be enrolled. These patients will be classified as ST-segment elevation (STEMI) group or non-ST-segment elevation (NSTEMI) group according to their final diagnosis. Patient who had been excluded for acute coronary syndrome with serial unchanging ECGs AND negative serial troponins will constitute a third group. Allocation to each group will be continued until the patient number in each group reaches up to 1000 patients. The dead or alive status of all included patients will be checked from the electronic national database.
All ECGs will be reviewed by two cardiologists blinded to the angiographic and clinical outcomes. The presence of predefined ECG findings of ACO (including, but not limited to, current established STEMI criteria) will be recorded. The coronary angiograms of the first two groups will be reviewed for ACO by independent investigators who are blinded to ECG parameters. The diagnosis of acute coronary occlusion will be dependent upon angiographic occlusion and rising cardiac biomarker levels. Because in some cases of ACO, the artery may spontaneously open by the time of the angiogram, the investigators will need to have surrogate endpoints: this will be culprit lesion OR acute occlusion on the angiogram AND a sufficiently elevated peak troponin, i.e., peak troponin I > 1.0 ng/mL with a 20% change within first 24 hours OR peak troponin T > 5.0 ng/mL, which have been shown to be highly correlated with ACO OR cardiac arrest in a clinical scenario compatible with ACO before blood could be withdrawn for troponin essay.
The sensitivity, specificity and diagnostic accuracy of all these predefined ECG criteria will be sought. Also, sensitivity, specificity and diagnostic accuracy of current established STEMI criteria will be defined. Both short- and long-term mortality of the patients with a diagnosis of STEMI with ACO, STEMI without ACO, NSTEMI with ACO, NSTEMI without ACO and chest pain without acute coronary syndrome will be compared.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| STEMI | Current international ECG criteria (New ST-segment elevation at the J-point in two contiguous leads with the cut-points: ≥0.1 mV millivolts (mV) in all leads other than leads V2-V3; for leads V2-V3: ≥2 mm in men ≥40 years; ≥2.5 mm in men <40 years, or ≥1.5 mm in women regardless of age) with troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia. |
| |
| NSTEMI | Troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia without abovementioned criteria. |
| |
| Normal | Emergency department admission with a clinical picture compatible with acute coronary syndrome, but no change in serial ECGs and no rise in cardiac biomarkers |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Coronary angiogram | Radiation | Routine coronary angiogram, if indicated |
|
| Measure | Description | Time Frame |
|---|---|---|
| The Sensitivity and Specificity of ECG for Acute Coronary Occlusion. | Determine the sensitivity and specificity of different ECG findings for acute coronary occlusion. The Number of Participants with Type 1a and 1b ECGs, as defined in the study protocol. | Up to 48 hours |
| Measure | Description | Time Frame |
|---|---|---|
| The Sensitivity and Specificity of Current "STEMI" Criteria for Acute Coronary Occlusion. | Determine the accuracy of current "STEMI" ECG criteria (as reported in the 4th universal definition of MI) in diagnosing acute coronary occlusion. Type 1a, 1c and 1d ECGs will be included in this group. | Up to 48 hours |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Acute coronary syndrome
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Dr. Siyami Ersek Training and Research Hospital | Istanbul | 34668 | Turkey (Türkiye) |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 32775606 | Derived | Aslanger EK, Yildirimturk O, Simsek B, Bozbeyoglu E, Simsek MA, Yucel Karabay C, Smith SW, Degertekin M. DIagnostic accuracy oF electrocardiogram for acute coronary OCClUsion resuLTing in myocardial infarction (DIFOCCULT Study). Int J Cardiol Heart Vasc. 2020 Jul 30;30:100603. doi: 10.1016/j.ijcha.2020.100603. eCollection 2020 Oct. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | STEMI | Current international ECG criteria (New ST-segment elevation at the J-point in two contiguous leads with the cut-points: ≥0.1 mV millivolts (mV) in all leads other than leads V2-V3; for leads V2-V3: ≥2 mm in men ≥40 years; ≥2.5 mm in men <40 years, or ≥1.5 mm in women regardless of age) with troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia. Coronary angiogram: Routine coronary angiogram, if indicated |
| FG001 | NSTEMI | Troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia without abovementioned criteria. Coronary angiogram: Routine coronary angiogram, if indicated |
| FG002 | Normal | Emergency department admission with a clinical picture compatible with acute coronary syndrome, but no change in serial ECGs and no rise in cardiac biomarkers |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | STEMI | Current international ECG criteria (New ST-segment elevation at the J-point in two contiguous leads with the cut-points: ≥0.1 mV millivolts (mV) in all leads other than leads V2-V3; for leads V2-V3: ≥2 mm in men ≥40 years; ≥2.5 mm in men <40 years, or ≥1.5 mm in women regardless of age) with troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia. Coronary angiogram: Routine coronary angiogram, if indicated |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | The Sensitivity and Specificity of ECG for Acute Coronary Occlusion. | Determine the sensitivity and specificity of different ECG findings for acute coronary occlusion. The Number of Participants with Type 1a and 1b ECGs, as defined in the study protocol. | The occurrence of type 1a and 1b ECGs in subgroups | Posted | Count of Participants | Participants | Up to 48 hours |
|
1.5 years
Survival/mortality
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | STEMI | Current international ECG criteria (New ST-segment elevation at the J-point in two contiguous leads with the cut-points: ≥0.1 mV millivolts (mV) in all leads other than leads V2-V3; for leads V2-V3: ≥2 mm in men ≥40 years; ≥2.5 mm in men <40 years, or ≥1.5 mm in women regardless of age) with troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia. Coronary angiogram: Routine coronary angiogram, if indicated |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| In hospital mortality | Cardiac disorders | Systematic Assessment | Serious event |
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Emre Aslanger | Yeditepe University | 0216578000 | 4240 | mr_aslanger@hotmail.com |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP_ICF | Yes | Yes | Yes | Study Protocol, Statistical Analysis Plan, and Informed Consent Form | Apr 23, 2017 | Sep 4, 2020 | Prot_SAP_ICF_000.pdf |
Not provided
| ID | Term |
|---|---|
| D009203 | Myocardial Infarction |
| D054058 | Acute Coronary Syndrome |
| D003324 | Coronary Artery Disease |
| D000072657 | ST Elevation Myocardial Infarction |
| D000072658 | Non-ST Elevated Myocardial Infarction |
| D054059 | Coronary Occlusion |
| D003328 | Coronary Thrombosis |
| D017202 | Myocardial Ischemia |
| D003327 | Coronary Disease |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
| D007238 | Infarction |
Not provided
Not provided
Not provided
Not provided
Not provided
| The Sensitivity and Specificity of ECG Without ST-segment Elevation for Acute Coronary Occlusion |
Determine the accuracy of ECG interpretation of acute coronary occlusion without STEMI criteria. Only type 1b ECGs will be included in this group. |
| Up to 48 hours |
| The Specificity of ECG With STEMI Criteria | Explore the rationale for correct ECG interpretation of false positive STEMI criteria. Only type 1c and 1d ECGs will be included in this group. | Up to 48 hours |
| The Sensitivity of ECG With STEMI Criteria | Explore the rationale for correct ECG interpretation of false negative STEMI criteria. The occurrence of type 1c ECGs in subgroups will be compared. | Up to 48 hours |
| The Outcome (Mortality) According to ECG Subclassifications (STEMI/NSTEMI/Control Groups) | Compare the outcomes of the patients who are labeled as STEMI and the patients who are labeled as having NSTEMI but have acute coronary occlusion. | Up to one year |
| BG001 | NSTEMI | Troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia without abovementioned criteria. Coronary angiogram: Routine coronary angiogram, if indicated |
| BG002 | Normal | Emergency department admission with a clinical picture compatible with acute coronary syndrome, but no change in serial ECGs and no rise in cardiac biomarkers |
| BG003 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| Hypertension | Count of Participants | Participants |
|
| Dyslipidemia | Count of Participants | Participants |
|
| Diabetes | Count of Participants | Participants |
|
| Smoking | Count of Participants | Participants |
|
| Prior myocardial infarction | Count of Participants | Participants |
|
| Prior percutaneous coronary intervention (PCI) | Count of Participants | Participants |
|
| Prior coronary artery by-pass operation | Count of Participants | Participants |
|
| Systolic blood pressure | Mean | Standard Deviation | mmHg |
|
| Heart rate | Median | Inter-Quartile Range | bpm |
|
| Electrocardiogram to percutaneous coronary intervention time | Median | Inter-Quartile Range | minutes |
|
| Grace risk score | GRACE risk score is a well known total score system with >140 being high risk. The range for GRACE risk score is from 0 to 263. | Median | Inter-Quartile Range | units on a scale |
|
| Creatinine | Mean | Inter-Quartile Range | mg/dL |
|
| Hemoglobin | Mean | Inter-Quartile Range | g/dL |
|
| Admission troponin | Median | Inter-Quartile Range | ng/ml |
|
| OG001 | NSTEMI | Troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia without abovementioned criteria. Coronary angiogram: Routine coronary angiogram, if indicated |
| OG002 | Normal | Emergency department admission with a clinical picture compatible with acute coronary syndrome, but no change in serial ECGs and no rise in cardiac biomarkers |
|
|
| Secondary | The Sensitivity and Specificity of Current "STEMI" Criteria for Acute Coronary Occlusion. | Determine the accuracy of current "STEMI" ECG criteria (as reported in the 4th universal definition of MI) in diagnosing acute coronary occlusion. Type 1a, 1c and 1d ECGs will be included in this group. | THe occurrence of type 1c and 1d ECGs in subgroups | Posted | Count of Participants | Participants | Up to 48 hours |
|
|
|
| Secondary | The Sensitivity and Specificity of ECG Without ST-segment Elevation for Acute Coronary Occlusion | Determine the accuracy of ECG interpretation of acute coronary occlusion without STEMI criteria. Only type 1b ECGs will be included in this group. | The occurrence of type 1b ECGs in subgroups | Posted | Count of Participants | Participants | Up to 48 hours |
|
|
|
| Secondary | The Specificity of ECG With STEMI Criteria | Explore the rationale for correct ECG interpretation of false positive STEMI criteria. Only type 1c and 1d ECGs will be included in this group. | The sum of type 1c and 1d ECGs in subgroups | Posted | Count of Participants | Participants | Up to 48 hours |
|
|
|
| Secondary | The Sensitivity of ECG With STEMI Criteria | Explore the rationale for correct ECG interpretation of false negative STEMI criteria. The occurrence of type 1c ECGs in subgroups will be compared. | The occurrence of type 1c ECGs in subgroups | Posted | Count of Participants | Participants | Up to 48 hours |
|
|
|
| Secondary | The Outcome (Mortality) According to ECG Subclassifications (STEMI/NSTEMI/Control Groups) | Compare the outcomes of the patients who are labeled as STEMI and the patients who are labeled as having NSTEMI but have acute coronary occlusion. | Posted | Count of Participants | Participants | Up to one year |
|
|
|
| 135 |
| 1,000 |
| 83 |
| 1,000 |
| 0 |
| 1,000 |
| EG001 | NSTEMI | Troponin rise above 99th percentile in a clinical situation suggestive of myocardial ischemia without abovementioned criteria. Coronary angiogram: Routine coronary angiogram, if indicated | 60 | 1,000 | 27 | 1,000 | 0 | 1,000 |
| EG002 | Normal | Emergency department admission with a clinical picture compatible with acute coronary syndrome, but no change in serial ECGs and no rise in cardiac biomarkers | 1 | 1,000 | 0 | 1,000 | 0 | 1,000 |
Not provided
Not provided
| D007511 |
| Ischemia |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D009336 | Necrosis |
| D001161 | Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D013927 | Thrombosis |
| D016769 | Embolism and Thrombosis |