Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Design: PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (left ventricular) function assessed on local standards, of ischemic origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation.
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
Hypothesis: The primary alternative hypothesis states that the mean relative infarct transmurality (RIT) is different in patients with (RITshock or ATP (Anti Tachy Pacing)) and without (RITno shock or ATP )appropriate ICD intervention, i.e. shock or ATP.
Sample size: 200 patients.
Follow-up: Enrolment visit, pre implant screening, ICD implantation, pre-hospital discharge visit, and follow-up (FUP) visits at 2, 6, 12, 18, 24 months including home monitoring. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Rationale: Implantation of an ICD as primary prevention therapy is indicated according to the current guidelines based on the low LVEF (Left Ventricular Ejection Fraction) as it was shown to significantly reduce mortality. Although of proven efficacy, ICD therapy is associated with survival benefit in only a small fraction of patients. It is estimated that 18 patients would have to receive an ICD to save one life, resulting in a huge burden on national health systems. Moreover, only about one quarter of all guideline eligible primary prevention ICD patients receive appropriate shocks. The above considerations support the need for an effective risk-stratification method to identify patients that benefit most (or least) from this therapy. Evaluation of ventricular anatomy and function by imaging techniques has become more important since this provides information on the substrate (myocardial scar) and trigger of life-threatening ventricular arrhythmias. Besides accurate estimation of left and right ventricular volumes and functions, Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging has a very high sensitivity to detect myocardial scar. Quantification of scar characteristics by cardiac MRI might be useful for the prediction of future arrhythmic events in patients with ischemic cardiomyopathy. However evidence is conflicting and published papers are hampered by limited patient numbers and can only be regarded in the light of generating hypothesis. The PARCADIA clinical investigation will explore the potential of cardiac MRI as a predictor for appropriate ICD intervention in a multicenter setting.
PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (Left Ventricular) function assessed on local standards, of ischemic (at least 40 days post-MI (myocardial infarction) or 3 months post revascularization) origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation
General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).
The primary objective of the clinical investigation is to determine whether there is a relationship between appropriate ICD intervention (shock or ATP) and the Relative Infarct Transmurality (RIT) obtained from Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging in patients with ischemic cardiomyopathy, receiving an ICD for primary prevention.
Methodology: Screening: (within 6 months before enrolment) patients with LV depressed function due to Ischemic Cardiomyopathy with an indication for primary prevention ICD implantation according to ESC (European Society of Cardiology) guidelines or local standards will be screened within 6 months before enrolment.
pre implant diagnostics: within 3 months after enrolment LGE-CMR imaging, 24h holter, 12-lead ECG, will be performed and biochemical markers will be obtained.
ICD implantation: Implantation of a Lumax 540 single/dual chamber ICD or successor withiin 3 months after enrolment. The ICD will be programmed according to protocol.
Pre-hospital discharge an ICD interrogation wil be performed. Follow-up (FUP) visits at: 2, 6, 12, 18, 24 months with inclusion of standard 12-lead ECG, ICD check-up and cardiologist visit in the outpatient clinic. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ICD implantation | Other | Implantation of a Lumax 540 single/dual chamber ICD or successor according to local practice within 3 months after enrolment. The patient will be implanted with a single or dual chamber device according to ESC guidelines. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ICD implantation | Device | implantation of the Lumax 540 single/dual chamber ICD or successor |
|
| Measure | Description | Time Frame |
|---|---|---|
| Relative Infarct Transmurality | Percentage Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR | Measured during Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) imaging within 3 months after inclusion and before ICD implantation |
| appropriate ICD intervention (shock or ATP) | assessment whether patient had appropriate ICD intervention (shock or ATP) or not during 24 months follow-up. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee. | Until the 24 month follow-up |
| Measure | Description | Time Frame |
|---|---|---|
| LV function (EF) | Left Ventricular function (Ejection Fraction in %) measured during LGE-CMR at baseline before ICD implantation | Baseline |
| LV mass | LV mass measured during LGE-CMR at baseline before ICD implantation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The study model is single group. At the analysis the patients will be divided in two groups bij outcome of ICD therapy/no ICD therapy.
The endpoints related to the primary hypothesis are appropriate ICD intervention (shock or ATP) and Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee.
Not provided
Not provided
Not provided
Not provided
| Baseline |
| total infarct mass | total infarct mass measured during GGE-CMR at baseline before ICD implantation | Baseline |
| transmural infarct mass | transmural infarct mass measured during LGE-CMR at baseline before ICD implantation | Baseline |
| mean Heart Rate (HR) | mean HR measured by 24-hrs Holter | Baseline |
| Day and night HR | Day and night HR measured by 24-hrs Holter | baseline |
| spontaneous episodes of atrial and ventricular arrhythmias | number of spontaneous episodes of atrial and ventricular arrhythmias measured by 24-hrs Holter | baseline |
| heart rate variability (SDNN: Standard deviation of consecutive normal-to-normal intervals) | heart rate variability (SDNN) measured by 24-hrs Holter | baseline |
| HR | HR on 12 lead ECG | baseline |
| rhythm | rhythm on 12 lead ECG | baseline |
| QRS width | QRS width on 12 lead ECG | baseline |
| serum sodium and potassium | concentration of serum sodium and potassium (in mmol/l ) (blood sample) | baseline |
| serum creatinine | concentration of serum creatinine (in umol/l) (blood sample) | baseline |
| uric acid | concentration of uric acid (in mmol/l) (blood sample) | baseline |
| albumin | concentration of albumin (in g/l) (blood sample) | baseline |
| HbA1c (Hemoglobin A1c) | concentration HbA1c (mmol/mol) (blood sample) | baseline |
| NT-proBNP (N-terminal pro-hormone Brain Natriuretic Peptide) | concentration NT-proBNP (in pg/ml) (blood sample) | baseline |
| hsTNT/I (high sensitive Troponin-T/I) | concentration hsTNT/I (in ng/ml) (blood sample) | baseline |
| aldosterone | concentration aldosterone (in pmol/l) (blood sample) | baseline |
| incidence of hypertension | Baseline clinical demographics: hypertension in clinical history | baseline |
| incidence of diabetes | Baseline clinical demographics: diabetes in clinical history | baseline |
| incidence of hypercholesterolemia | Baseline clinical demographics: hypercholesterolemia in clinical history | baseline |
| PVC/hr: Premature ventricular contraction per hour | PVC/hr: Premature ventricular contraction per hour on 24hrs Holter | baseline |