The investigators will evaluate the diagnostic yield of the new AliveCor device versus a 12 lead ECG when used simultaneously to detect cardiac arrhythmia
The investigators are planning to record 250 pre-defined abnormal ECGs (50 each of atrial fibrillation, atrial flutter, pre-excitation, ventricular tachycardia, , supraventricular tachycardia) and 150 control ECGs (100 sinus rhythm, 50 sinus tachycardia) using both the AliveCor Smartphone device and a 12-lead ECG. All 400 ECGs will then be read by 3 blinded reporters - a Consultant Electrophysiologist, a Consultant General Cardiologist and a General Practitioner. The output of the AliveCor automatic detection algorithm will also be recorded as a fourth reporter. The screening characteristics of all 4 reporters using the AliveCor device vs the definitive 12 lead ECG will be analysed and compared.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Normal ECGs | Active Comparator | Patients with normal ECGs |
|
| Abnormal ECGs | Active Comparator | Patients with different kinds of abnormal heart rhythms will be enrolled in order to compare whether Alivecor can accurately differentiate between these abnormal heart rhythms and normal sinus rhythm/sinus tachycardia. Also, Alivecor diagnostic accuracy in differentiating between different kinds of arrhythmias will be assessed. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Alivecor recording | Device | Alivecor recording and ECG recording from the same patient in very close temporal proximity |
|
| Measure | Description | Time Frame |
|---|---|---|
| Diagnostic accuracy of alivecor recording | For each patient two diagnoses of their underlying heart rhythm will be provided by blinded reporters. The percentage match of these diagnoses (the ratio of identical diagnoses to mismatch in diagnoses between ECG report and Alivecor report will be used as a measure of accuracy of the Alivecor to differentiate between different heart rhythms, using the 12 lead ECG as the gold standard for cardiac rhythm diagnosis. | Diagnostic accuracy of Alivecor recording at the end of the study which will be 2 years after study start date. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Khalid Abozguia, Ph.D. | Contact | 00441253957780 | k.abozguia@nhs.net | |
| Dimitrios Katsaras, MD | Contact | 00441253957780 | d.katsaras@nhs.net |
| Name | Affiliation | Role |
|---|---|---|
| Khalid Abozguia, Ph.D. | Blackpool Teaching Hospitals NHS Foundation Trust | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Blackpool Teaching Hospitals NHS Foundation Trust | Recruiting | Blackpool | Lancashire | FY3 8NR | United Kingdom |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jul 27, 2018 | May 27, 2019 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Recordings with Alivecor and 12 lead ECGs with be acquired from patients with known arrhythmias/normal heart rhythm and blinded physicians will report on recordings and ECGs. Reports for each patient will be compared at the end of the study in order to assess diagnostic accuracy of the Alivecor to detect and differentiate between different kinds of abnormal heart rhythms.
Not provided
Not provided
Not provided