Cervical range of motion (ROM) is necessary to perform normal activities of daily living and deficits are associate with various pathologies. Currently, its unclear if specific myofascial stretches will improve cervical range of motion and decrease myofascial sensitivity. After a single session of the manual stretching procedure, participants immediately demonstrated increased cervical ROM and pressure pain thresholds.
Methods: Sixty participants with no history of neck pain or trauma were randomized into one of two groups: stretching group (n = 30), or control group (n = 30). The stretching group received a standardized manual stretching protocol. The control group did not received intervention. Pre and Post-test measurements were recorded for both groups. Within group differences and group by time interactions were evaluated for Cervical range of motion ROM and myofascial sensitivity. The immediate improvement in active ROM of the cervical spine may prompt clinicians to consider the sequencing of treatment. Stretching prior to active exercises may allow for active exercise through a larger ROM. Future research is needed to evaluate the immediate effects of stretching in the symptomatic population.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control group | No Intervention | The control group did not received intervention and sat on a table for approximately 5 minutes | |
| Stretching group | Experimental | The stretching group received a standardized manual stretching protocol |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Manual stretching | Procedure | Manual stretching for the upper trapezius and levator scapulae muscle |
|
| Measure | Description | Time Frame |
|---|---|---|
| Range of Motion | CROM including flexion, extension, side bending left, side bending right, rotation left, and rotation right | 1 minute post-intervention |
| Measure | Description | Time Frame |
|---|---|---|
| Pressure pain thresholds | The PPT was recorded using a Wagner FDX-25 hand-held digital pressure algometer (Wagner Instruments, Greenwich, CT). The investigator performed each assessment uniformly by applying force at the same rate of 5 Pa/second. | 1 minute post-intervention |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| William J Hanney, PhD | University of Central Florida | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Central Florida | Orlando | Florida | 32816 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Randomized controlled trial
Not provided
Not provided
Assessor of dependent variables was blinded to group assignment