Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Glaukos Corporation | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
To assess the improvement in refractive error and the corneal endothelial safety with a customized corneal crosslinking treatment regimen for low grade myopia. The study compares two treatment protocols, a 4.0-mm central ring-shaped zone with a 3.5-mm central ring-shaped zone in high oxygen environment without corneal epithelial debridement.
The study design is a prospective, single-masked intraindividually comparing randomized controlled trial, conducted at the Department of Clinical Sciences / Ophthalmology, Umeå University Hospital, Umeå, Sweden. The study includes healthy men and women with low grade myopia, aged between 18-35 years and involves 27 participants with a myopia of -0.5 to -2.5 diopters (D) and astigmatism of ≤0.75D. All participants are treated with phototherapeutic intrastromal corneal collagen cross-linking (PiXL) without epithelial debridement (epi-on), after topical riboflavin. Both eyes are treated and randomized to receive ultraviolet (UV) light according to PiXL 4.0 mm treatment zone in one eye and PiXL 3.5 mm treatment zone in the other, which is masked to the participant. For myopia <0.75D, 10 J/cm^2 is used and for higher levels of myopia 15J/cm^2 is used. Throughout the treatment, humidified oxygen is continuously delivered around the eye using an oxygen mask to achieve an oxygen concentration of ≥95 percentage. All participants are informed about the procedures and provide oral and written consent before inclusion in the study.
At baseline, each eye is examined with slit-lamp microscopy, subjective refraction, determination of uncorrected (UCVA), low contrast visual acuity at 2.5 percentage and 10 percentage contrast and best corrected (BSCVA) visual acuities using the LogMAR fast protocol and intraocular pressure (IOP) using Goldmann applanation tonometry. Under standardized, mesopic light conditions each eye is evaluated by keratometry readings, central corneal thickness and after treatment also the depth of demarcation lines, extracted from Schemipflug camera measurements, Pentacam HR® (Oculus, Inc. Lynnwood, WA). Central corneal endothelial photographs are taken with the Topcon SP-2000P specular microscope (Topcon Europe B.V., Capelle a/d Ijssel, the Netherlands), from which the corneal endothelial cell count is manually calculated from a cluster of 25 cells from each photograph. Total ocular wavefront is measured with iTrace (Tracey Technologies, Inc.).
All the above mentioned examinations are reassessed at 1, 3 and 6 and 12 months after treatment. At 1 day and 1 week after treatment, solely UCVA, Auto refractor measurements, slit-lamp examination and a subjective comparison of discomfort and visual performance in each eye are evaluated.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 4.0 mm zone | Active Comparator | PiXL treatment with UV irradiation in a central 4.0-mm ring-shaped zone of the cornea. The area consist of three rings with a central 2-mm zone that is left untreated. The energy is higher towards the periphery of the ring-shaped area, reaching its maximum at 2-mm from the corneal centre. Pulsed UV-light, 1s on / 1s off; 30mW. For myopia of less than 0.75D, 10 J/cm2 is used, for higher levels of myopia 15J/cm2 is used. |
|
| 3.5 mm zone | Experimental | PiXL treatment with UV irradiation in a central ring-shaped 3.5-mm zone of the cornea, with a central 1.5 mm zone that is left untreated. The illumination area consists of three rings, where the outer and inner ring are thinner than the middle ring. The maximum energy is distributed in the middle ring. Pulsed UV-light, 0.5s on / 1s off; 45mW. For myopia of less than 0.75D, a maximum of 10 J/cm2 is used, for higher levels of myopia a maximum of 15J/cm2 is used. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 4.0 mm treatment | Procedure | PiXL treatment with UV irradiation in a central 4.0-mm ring-shaped zone of the cornea. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Change from baseline in uncorrected visual acuity | Change from baseline in distance uncorrected visual acuity | 1, 3, 6, 12 and 24 months after treatment |
| Change from baseline in spherical equivalent | Change from baseline in spherical equivalent on subjective distance refraction | 1, 3, 6, 12 and 24 months after treatment |
| Measure | Description | Time Frame |
|---|---|---|
| Change from baseline in corneal endothelial cell density | Change from baseline in central corneal endothelial cell density | 12 and 24 months after treatment |
| Change from baseline in best corrected visual acuity |
Not provided
Inclusion Criteria:
Spherical equivalent on distance subjective refraction between -0.50D and -2.50D.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Anders Behndig, MD, PhD | Department of Clinical Sciences/Ophthalmology, Umeå University, Umeå, Sweden | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Clinical Sciences/Ophthalmology, Umeå University | Umeå | 901 85 | Sweden |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D009216 | Myopia |
| D012030 | Refractive Errors |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Prospective, single-masked intraindividually comparing randomized controlled trial. Participants will be randomized to receive ultraviolet (UV) light according to protocol A in one eye and protocol B in the other, which is masked to the participant. Both eyes will be treated during the same visit. Participants are randomized utilizing a computer list of unique random numbers between 1 and 27; an even number will be treated with the 4.0-mm zone in the right eye; an uneven number with the 4.0-mm zone in the left eye.
Not provided
Not provided
The participants are not aware which eye will receive the 4.0-mm ring-shaped zone treatment and which eye will receive the 3.5-mm ring-shaped zone treatment.
| 3.5 mm treatment | Procedure | PiXL treatment with UV irradiation in a central 3.5-mm ring-shaped zone of the cornea. |
|
Change from baseline in best spectacle corrected distance visual acuity
| 1, 3, 6, 12 and 24 months after treatment |