Not provided
Not provided
Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| IRAS Project ID: 260562 | Other Identifier | Health Research Authority |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| The British Society of Endovascular Therapy (BSET) | UNKNOWN |
Not provided
Not provided
Not provided
Not provided
The purpose of the BSET-CLEVAR Registry is to collect device-specific performance outcomes of the GORE® EXCLUDER® Conformable AAA Endoprosthesis with ACTIVE CONTROL System (EXCC device) in routine clinical treatment of patients with abdominal aortic aneurysm in the UK.
The novel EXCC device is an evolution of an established device allowing active shaping to conform to the specific patient aortic neck anatomy, with more accurate deployment, potentially greater neck coverage and better long term fixation/sealing. This may translate to improved effectiveness of this device over time, reducing the need for any further procedures. The primary aim of this study is to assess the degree of neck coverage by the EXCC device.
The British Society of Endovascular Therapy (BSET) has received funds from the stent manufacturer (W.L. Gore & Associates, Inc.) to conduct this study. BSET and the Sponsor (Imperial College London) have full responsibility for the design, conduct, analysis and reporting of the study.
An abdominal aortic aneurysm (AAA) is a 'bulge' caused by weakness of the wall of the aorta (main blood vessel) in the section that travels down through the abdomen. An AAA can grow to a large size over time and it may burst (rupture), causing life-threatening internal bleeding. The standard method to prevent the AAA from bursting is to re-line the aorta with an artificial piece of rigid tubing called a stent that has been covered with material. This is inserted through the blood vessels from the artery in the groin to stop the aneurysm from expanding and restore normal diameter of the aorta. This is commonly known as a 'keyhole'or minimally invasive approach called endovascular aneurysm repair (EVAR).
There have been many advances in stent-graft technology to improve the accuracy and effectiveness of the EVAR procedure. A new design of an existing stent-graft that is currently being used in patients in many hospitals is the GORE® EXCLUDER® Conformable AAA Endoprosthesis with ACTIVE CONTROL (also known as EXCC Device). This new device allows the operator to shape the upper end of the device so that it may be placed into the aorta more accurately, conforming to the shape of the aorta, potentially improving the fixation and long-term sealing of the aneurysm, which may translate to a reduction in the need for further procedures.
This study is a prospective, multi-centre observational cohort registry of patients undergoing routine clinical treatment of AAA by the EXCC device. Recruitment will take place in 13 experienced UK centres with extensive EVAR experience. Up to 150 participants will be recruited in 30 months and followed-up to 1 year (participants will not undergo any procedure that is not part of their routine clinical care). Clinical data and device specific outcomes, including complications and re-interventions will be prospectively collected. In addition, the BSET-CLEVAR Registry Core Lab will evaluate both the pre-operative CT scan and the post-operative CT scan (obtained between 4 weeks and 3-months following EVAR), to assess the primary outcome of the study (endograft positioning accuracy and aortic neck coverage expressed as percentage of the total aortic neck assessed). Study outcomes will also include detailed analysis of pathological and anatomical features of the aneurysm and the EXCC device, which will be used for reporting the effectiveness of the graft. A detailed statistical analysis plan will be written prior to the final analysis.
The Study Co-ordinating Centre based at Imperial College London is responsible for the overall coordination of the Study, including monitoring of the overall study progress and review of study data accuracy (which, if necessary, may be checked by auditing the source data).
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Endograft positioning accuracy and aortic neck coverage expressed as percentage of the total aortic neck assessed by CT images | The median aortic neck surface area utilized will be calculated from pre- and post-operative CT images, which will be obtained between 4 weeks and 3 months following primary EVAR procedure (timing depends on local EVAR surveillance policy) | between 4 weeks and 3 months following EVAR |
| Measure | Description | Time Frame |
|---|---|---|
| Technical success defined as successful access and deployment of all required EXCC Device components | (Yes/No) - Success defined as no type I/III endoleak, no conversion to open repair & patient leaving theatre alive; to be assessed by the operating clinician on completion of EVAR | At the end of the primary procedure |
Not provided
Inclusion Criteria:
The patient is / has:
Exclusion Criteria:
The patient is / has:
Not provided
Not provided
Not provided
Patients with abdominal aortic aneurysm who are suitable for endovascular repair of their AAA and are either being considered for or have received treatment by endoprosthesis implantation as part of their routine care at a participating NHS hospital
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Colin D Bicknell, MB MD FRCS | Imperial College London | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hull & East Yorkshire Hospitals NHS Trust (Hull Royal Infirmary) | Hull | East Yorkshire | HU3 2JZ | United Kingdom | ||
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Oct 8, 2024 | |
| Reset | Nov 29, 2024 |
Not provided
Not provided
Not provided
Not provided
| In-hospital mortality |
Death occurring during hospital stay for EVAR |
| During hospital admission for the primary EVAR procedure, to be reported for up to 12 months following the primary procedure |
| Adjunct (supplementary) procedures received by the patient to resolve Type 1 endoleak on completion of EVAR | Further steps (procedures) required to deal with type 1 endoleak (a failure of the first section of the stent-graft as it is fixed in the aorta below the renal arteries) | At the end of the primary EVAR procedure |
| Freedom from Type 1 or 3 endoleak | No type 1 endoleak (a failure of the first section of the stent-graft as it is fixed in the aorta below the renal arteries) or Type 3 endoleak (a failure of sealing of the components of the stent-graft) | At the end of the primary procedure; at first follow-up (between 4 weeks and 3 months); at second follow-up (1 year) |
| One-year aneurysm-related re-intervention rate | Any further aneurysm-related procedures that occur within 12 months following EVAR | One year after the primary procedure |
| One-year aneurysm-related mortality | Vital status of the patient one year after undergoing EVAR | One year after the primary procedure |
| Frimley Health NHS Foundation Trust |
| Frimley |
| Surrey |
| GU16 7UJ |
| United Kingdom |
| Imperial College Healthcare NHS Trust (St Mary's Hospital) | London | Westminster | W2 1NY | United Kingdom |
| NHS Grampian | Aberdeen | AB25 2ZN | United Kingdom |
| Bedford Hospital NHS Trust | Bedford | MK42 9DJ | United Kingdom |
| University Hospitals Dorset NHS Foundation Trust | Bournemouth | BH7 7DW | United Kingdom |
| Cambridge University Hospitals NHS Foundation Trust | Cambridge | CB2 0QQ | United Kingdom |
| Gloucestershire Hospitals NHS Foundation Trust | Cheltenham | GL53 7AN | United Kingdom |
| NHS Tayside | Dundee | United Kingdom |
| Leeds Teaching Hospitals NHS Trust | Leeds | LS1 3EX | United Kingdom |
| Liverpool University Hospitals NHS Foundation Trust | Liverpool | United Kingdom |
| Guy's and St Thomas' NHS Foundation Trust | London | SE1 7EH | United Kingdom |
| Norfolk and Norwich University Hospitals NHS Foundation Trust | Norwich | United Kingdom |
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Oct 8, 2024 | Nov 29, 2024 |