This is a prospective pilot to investigate the effect of 3D printer customized CPAP masks on the comfort of patients with obstructive sleep apnea.
Purpose:
The purpose of this protocol is to perform a prospective pilot clinical study to customize patient CPAP masks to reduce air leak in patients with obstructive sleep apnea (OSA). Using 3-D printer-based technology modeling of patient facial features, patient FDA-approved CPAP masks will be modified by strategically applying silicone pads on the CPAP mask to mold to the specific facial features to optimize the CPAP mask-patient interface, improve CPAP mask fit and comfort, reduce air leak, limit air pressure loss and improve compliance with CPAP treatment strategy (as measured over a 30 day trial period).
Protocol:
Potential subjects for this study will be identified at the outpatient Sleep Disorders Clinic at BIDMC. Patients will have documented OSA, prescribed CPAP as standard-of-care, and demonstrate consistent problems with CPAP mask-patient interface with documented high air loss, and poor adherence/ compliance. All potential subjects will have used and will continue to use an FDA-approved CPAP mask selected by the patient.
Potential subjects (along with their FDA-approved CPAP mask) will then be referred to the BIDMC Specialties Clinic and screened, including review of the medical history of OSA, review of documented reports of excessive air leak and suboptimal adherence to CPAP, brief physical exam (esp. focusing on the head-and-neck exam) including assessment of the CPAP mask-patient interface, review of the purpose and goals of the pilot clinical study, a dynamic video of the study subject face will be performed, video downloaded to a computer which will then be used to generate a 3-dimensional plastic model of the study subject face using state-of-the-art 3D printer technology (see details below). The patient's FDA-approved CPAP mask will then be applied to his plastic model of the study subject face, and the CPAP mask modified with the application of silicon pads along the mask pillow cushion to optimize the CPAP mask-face model interface, primarily by adjustments to improve CPAP mask contact with the face model and limit the air leak during CPAP ventilation.
Once the patient's FDA-approved CPAP mask has been modified, the patient will then return to the BIDMC Specialties Clinic for a final fitting of the modified CPAP mask, with additional adjustments (as necessary) made to optimize the CPAP mask-patient interface. The study subject will then return home with his/her custom-modified CPAP mask to use as prescribed. Standard home monitoring and recording of use of the modified CPAP mask will be performed per usual case over a 30-day period. Data obtained during this 30-day period will focus on the duration of use of the modified CPAP mask, measurement of air leak and pressure loss, report of patient comfort and experience with the modified CPAP mask, and compare to data over a 30 day period using the CPAP mask prior to modification.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Modified CPAP | Experimental | Single arm cohort study of modified mask |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Custom CPAP mask | Device | Modified CPAP mask based on 3D image capture |
|
| Measure | Description | Time Frame |
|---|---|---|
| Air leak time | Percent of air leak time over use of mask | 30 day |
| Measure | Description | Time Frame |
|---|---|---|
| CPAP mask leak volume | Volume of leak recorded on CPAP machine | 30 day |
| Epworth Sleepiness Scale | Sleepiness score - Likelihood of falling asleep in various daytime activities. Total Score Range 0-24. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Chee ChunMin, MD | Beth Israel Deaconess Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Beth Israel Deaconess Medical Center | Boston | Massachusetts | 02215 | United States |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Jul 20, 2022 | Aug 11, 2022 | 2 | ||
| Jul 28, 2023 |
| ID | Term |
|---|---|
| D020181 | Sleep Apnea, Obstructive |
| ID | Term |
|---|---|
| D012891 | Sleep Apnea Syndromes |
| D001049 | Apnea |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Cohort study of intervention
Not provided
Not provided
Not provided
Not provided
| 30 day |
| Apnea Hypopnea Index | Apnea Hypopnea Index (events/hour) | 30 day |
| CPAP Inspiratory pressure | Inspiratory pressure setting on CPAP machine (cm H2O) | 30 day |
| Jul 31, 2023 |
| 3 |
| D020919 |
| Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
| D012893 | Sleep Wake Disorders |
| D009422 | Nervous System Diseases |