The efficacy of supraglottic airway device use in many surgeries has been shown. Due to concerns such as tracheal blood leakage and vocal cord contamination in nasal septum surgery, there are doubts about the use of laryngeal mask airway among anesthesiologists.
The primary purpose of this study is; the aim of this study was to evaluate the tracheal blood leak with a flexible fiberoptic endoscope in patients who underwent nasal septum surgery and continued airway patency via laryngeal mask airway or endotracheal tube. Secondly, oropharyngeal leak pressure, hemodynamic response, airway reflexes (laryngospasm, bronchospasm, cough, desaturation), postoperative nausea, vomiting, sore throat, hoarseness and difficulty in swallowing will be evaluated.
Airway management is one of the main issue of anesthesia practice. The use of endotracheal tubes has been accepted as the standard method for many years. High pressure and long-term use of cuffed tubes related to mucosal hypoperfusion and submucosal stenosis are important. The laryngeal mask airway is produced in the 1980s and considered as a supraglottic airway used to provide airway clearance in short-term surgical procedures. The laryngeal mask airways have recently found to use in many general anesthesia applications as a minimally invasive airway method and continue to be used increasingly. More appropriate supraglottic airway vehicles with different characteristics in terms of efficacy and side effects are being developed.
Laryngeal mask airway-Supremeâ„¢ is latex-free, semi-rigid, elliptical and anatomical shape due to the fingers in the mouth of the patient easily and quickly without inserting the new generation laryngeal mask airways. Designed to provide higher sealing pressures than the laryngeal mask airway-classic. In addition, the presence of a gastric canal for gastric tube passage is another important advantage.
The efficacy of supraglottic airway device use in many surgeries has been shown. Due to concerns such as tracheal blood leakage and vocal cord contamination in nasal septum surgery, there are doubts about the use of laryngeal mask airway among anesthesiologists.
The primary purpose of this study is; the aim of this study was to evaluate the tracheal blood leak with a flexible fiberoptic endoscope in patients who underwent nasal septum surgery and continued airway patency via laryngeal mask airway or endotracheal tube. Secondly, oropharyngeal leak pressure, hemodynamic response, airway reflexes (laryngospasm, bronchospasm, cough, desaturation), postoperative nausea, vomiting, sore throat, hoarseness and difficulty in swallowing will be evaluated.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Laryngeal mask airway | Active Comparator | Patients will be maintained with laryngeal mask airway supreme during the septal surgery. |
|
| Endotracheal tube | Sham Comparator | Patients will be maintained with endotracheal tube during the septal surgery. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Laryngeal mask airway | Device | Patients will be maintained with laryngeal mask airway during the septal surgery. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Presence of blood in trachea | Presence of blood in trachea will be evaluated on a scale and it is defined as the level of presence of blood on glottis-trachea and distal trachea. (1 = no, 2 = mild, 3 = moderate, 4 = severe). | From the time 2minutes after the septal surgery to the time of extubation |
| Measure | Description | Time Frame |
|---|---|---|
| Sore-throat | Sore-throat is defined as constant pain felt independently of swallowing. The evaluation was made with 0 ile10 numerical pain rating scale. According to numerical pain rating scale, sore throat score was evaluated as; 0-1 none, 2-4 between mild, 5-7 intermediate and 8-10 severe N | From the time 10 minutes after awakening from anesthesia to the time 24 hours postoperatively |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Erol Karaaslan, Asst. Prof. | Inonu University Medical Faculty | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Inonu University Medical Faculty | Malatya | 44090 | Turkey (Türkiye) |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30069317 | Background | Mao S, Du X, Ma J, Zhang G, Cui J. A comparison between laryngeal mask airway and endotracheal intubation for anaesthesia in adult patients undergoing NUSS procedure. J Thorac Dis. 2018 Jun;10(6):3216-3224. doi: 10.21037/jtd.2018.05.74. | |
| 33407130 | Derived | Karaaslan E, Akbas S, Ozkan AS, Colak C, Begec Z. A comparison of laryngeal mask airway-supreme and endotracheal tube use with respect to airway protection in patients undergoing septoplasty: a randomized, single-blind, controlled clinical trial. BMC Anesthesiol. 2021 Jan 7;21(1):5. doi: 10.1186/s12871-020-01222-4. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Nov 28, 2018 | Apr 3, 2019 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D017214 | Laryngeal Masks |
| ID | Term |
|---|---|
| D007442 | Intubation, Intratracheal |
| D058109 | Airway Management |
| D013812 | Therapeutics |
| D007440 | Intubation |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Endotracheal tube | Device | Patients will be maintained with endotracheal tube during the septal surgery. |
|
| Oropharyngeal leak pressure | Oropharyngeal leak pressures were measured while the head was in neutral position. The flowmeter oxygen current was set at 3 L/min and the expiratory valve was closed. When an investigator who did not know which type of airway device was placed, another researcher looked at the current pressure value from the aneroid manometer and confirmed that the pressure remained constant (pressure gauge stability test). This value was recorded as the value of Oropharyngeal leakage pressure. To prevent lung exposure to barotrauma, the expiratory valve was opened when the peak inspiratory pressure reached 40 pressure, and the test was terminated. | From the time 2 minutes after anesthesia induction to the correction of inserted device 5 minutes after anesthesia induction |
| D008919 |
| Investigative Techniques |
| D008397 | Masks |
| D011482 | Protective Devices |
| D004864 | Equipment and Supplies |
| D000067393 | Personal Protective Equipment |
| D008420 | Manufactured Materials |
| D013676 | Technology, Industry, and Agriculture |