Chronic Obstructive Pulmonary Disease (COPD) is the fourth-leading cause of death. It is a progressive illness that requires life-long treatment.Promoting airway clearance (AC) using mucolytics together with airway clearance techniques (ACTs) form the basis for pulmonary therapy in COPD care.Therefore, new airway clearance modalities are required to decrease the detrimental effects of accumulated secretions in COPD.
One of the devices used in AC is the high frequency chest wall oscillation (The Vest). HFCWO involves the use of an inflatable vest/jacket that covers the chest and is attached to an air pulse-generating compressor which rapidly inflates and deflates the vest, producing oscillations to the chest wall of 5-25 Hz.
Another new airway clearance modality is oscillating positive expiratory pressure(Quake) which combines PEP therapy with high frequency oscillations.
The present study aimed to evaluate the effectiveness of the extra thoracic oscillations via high frequency chest wall oscillation vest (HFCWO) versus the intra thoracic oscillations via oscillatory positive expiratory pressure (OPEP) Quake device in COPD Group A: consists of 30 patients will be treated by high frequency chest wall oscillation vest along with their prescribed medical treatment. This program will be performed 4 times per week for 6 successive weeks.
Group B: consists of 30 patients will be treated by vibratory PEP (The Quake) along with their prescribed medical treatment. This program will be performed 4 times per week for 6 successive weeks.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Vest arm | Experimental | high frequency chest wall oscillation vest performed 4 times per week for 6 successive weeks for 30 patients |
|
| Quake arm | Experimental | Vibratory positive expiratory pressure quake performed 4 times per week for 6 successive weeks for 30 patients |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| High frequency extra thoracic oscillations vest | Device | Oscillations applied extra thoracic through vest device aiming for airway clearance |
|
| Measure | Description | Time Frame |
|---|---|---|
| Pulmonary function test (spirometry) |
| Before and 6 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| impulse oscillometry | The patient was in sitting position, Legs kept uncrossed The patient firmly supported his cheeks during measurement. The mouthpiece was at a comfortable height so that the neck is slightly extended and ensure that there is a tight seal between the mouthpiece and lips to prevent air leak. The patient was instructed to perform normal tidal breathing in a relaxed state during the procedure. The recording was performed for at least 30-45 s. During this period, around 120-150 sound impulses were pushed into the lungs from which the mean reactance and resistance values were determined at frequencies from 5 to 20 Hz. |
Not provided
Inclusion Criteria:
• All patients were diagnosed by chest physician based on the modified criteria defined in the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines 2017.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Nagwa M Badr, Professor | Professor physical therapy at Cairo university | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Faculty of physical therapy | Dokki | Giza Governorate | 12613 | Egypt |
Not provided
| ID | Term |
|---|---|
| D029424 | Pulmonary Disease, Chronic Obstructive |
| ID | Term |
|---|---|
| D008173 | Lung Diseases, Obstructive |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
| D002908 | Chronic Disease |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Intrathoracic oscillatory quake | Device | Oscillation introduced intrathoracic through quake device through placing quake in mouth and ordering patient to breathing to move secretions |
|
| before and 6 weeks |
| D020969 |
| Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |