Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study aims to evaluate brain death with optical probes. The changes of hemodynamic parameters including oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) were detected by near infrared spectroscopy probes attached on the forehead of patients. A multiple-phase protocol at varied fraction of inspired O2 were utilized during the assessment.
Brain death is an irreversible loss of all brain functions, and the assessment is crucial for organ supply for transplantation. The noninvasive, sensitive, universally available and timely ancillary method to assess brain death has not been established. This study aims to evaluate brain death with optical probes. The changes of hemodynamic parameters including oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) were detected by near infrared spectroscopy probes attached on the forehead of patients. A multiple-phase protocol at varied fraction of inspired O2 were utilized during the assessment. The concentration changes ratios of oxyhemoglobin to deoxyhemoglobin (Δ[HbO2]/Δ[Hb]) in the cerebral cortex of brain-dead patients were significantly higher than those of healthy subjects.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Brain death patients for HLH Oxygen | Brain-dead patients were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of high-low-high procedure. During the procedures, the Δ[Hb] and Δ[HbO2] time courses were collected by Optical monitor for hemodynamic parameter. |
| |
| Brain death patients for LHL Oxygen | Brain-dead patients were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of low-high-low procedure. During the procedures, the Δ[Hb] and Δ[HbO2] time courses were collected by Optical monitor for hemodynamic parameter. |
| |
| Healthy people for HLH Oxygen | Healthy people were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of high-low-high procedure. During the procedures, the Δ[Hb] and Δ[HbO2] time courses were collected by Optical monitor for hemodynamic parameter. |
| |
| Healthy people for LHL Oxygen | Healthy people were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of low-high-low procedure. During the procedures, the Δ[Hb] and Δ[HbO2] time courses were collected by Optical monitor for hemodynamic parameter. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Oxygen supply of high-low-high procedure | Procedure | The protocol consisted of 1-hour resting, 3-minute baseline measurement, half-hour measurement at 60% FIO2 (phase I, high oxygen), half-hour measurement at 40% FIO2 (phase II, low oxygen) and half-hour measurement at 60% FIO2 (phase III, high oxygen). |
| Measure | Description | Time Frame |
|---|---|---|
| Δ[HbO2] | The changes of oxyhemoglobin concentrations in prefrontal cortex. | 1 day during the whole experiment |
| Δ[Hb] | The changes of deoxyhemoglobin concentrations in prefrontal cortex. | 1 day during the whole experiment |
| Measure | Description | Time Frame |
|---|---|---|
| Heart rate | Heart rate of patient recorded by bed-side physiological monitor. | 1 day during the whole experiment |
| Blood pressure | Blood pressure of patient recorded by bed-side physiological monitor. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Patients who are in pregnancy or have plan to conception.
Patients who have vertebra surgery or have plan of surgery.
Patients who are inappropriate to join this trial judged by the radiologists or specialists.
Not provided
Not provided
Adult individuals of any gender. Mostly hired in the City of Tianjin, P.R.China
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| NIRS assessment for brain death | Recruiting | Tianjin | Tianjin Municipality | 300000 | China |
Not provided
| Label | URL |
|---|---|
| A published SCI paper named "Noninvasive and sensitive optical assessment of brain death" written by the investigaters | View source |
Not provided
Not provided
| ID | Term |
|---|---|
| D001926 | Brain Death |
| ID | Term |
|---|---|
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D003128 | Coma |
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Oxygen supply of low-high-low procedure | Procedure | The protocol consisted of 1-hour resting, 3-minute baseline measurement, half-hour measurement at 40% FIO2 (phase I, low oxygen), half-hour measurement at 60% FIO2 (phase II, high oxygen) and half-hour measurement at 40% FIO2 (phase III, low oxygen). |
|
| Optical monitor for hemodynamic parameter. | Device | Near infrared spectroscopy probes of tow wavelengths were attached on the subjects' foreheat to detect the changes of hemodynamic parameters. |
|
| 1 day during the whole experiment |
| D014474 |
| Unconsciousness |
| D003244 | Consciousness Disorders |
| D019954 | Neurobehavioral Manifestations |
| D009461 | Neurologic Manifestations |
| D003643 | Death |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |