The color change of endodontically treated teeth is a common concern in clinical practice. The objective of this study will be to evaluate, in vivo, the color change (ΔE00) caused by endodontic treatment. A randomized clinical trial (RCT) will be conducted with the objective of evaluating ΔE00 originated from epoxy resin (AH Plus) and mineral trioxide aggregate (MTA Fillapex) endodontic sealers, sectioned at the cervical level and 2 mm below, in a period between the immediate endodontic treatment versus after 3, 6 and 12 months.
The sample syze determined that 48 anterior teeth (incisors and canines) and posterior teeth (premolars) should be included in the study. The sealer and cut will be randomly determined at time of endodontic treatment, originating four groups (n = 12): AH Plus-Cervical, MTA Fillapex-Cervical, AH Plus-2mm and MTA-2mm. The endodontic access cavities will be sealed with resin composed of the color of the dental element. The mean, standard deviation and confidence interval (CI 95%) of the values of ΔE00 obtained for each sealer will be initially analyzed using the variable cut level (cervical or 2mm) using the T test. Indeed, the values of ΔE00 will be analyzed by two-way analysis of variance, where the level of the cut and the type of sealer will be the factors under study.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| AH Plus-Cervical | Experimental | The objective is evaluate the color change (ΔE00) originated from epoxy resin (AH Plus) endodontic sealer, sectioned at the cervical level. The ΔE00 will be evaluated using the measurements data obtained in a period between the immediate endodontic treatment versus after 3, 6 and 12 months. The values of ΔE00 obtained for each sealer, cut and time will be analyzed by multifactorial analysis to verify associations of the outcomes with the ΔE00. |
|
| MTA Fillapex-Cervical | Experimental | The objective is evaluate the color change (ΔE00) originated from mineral trioxide aggregate (MTA Fillapex) endodontic sealer, sectioned at the cervical level. The ΔE00 will be evaluated using the measurements data obtained in a period between the immediate endodontic treatment versus after 3, 6 and 12 months. The values of ΔE00 obtained for each sealer, cut and time will be analyzed by multifactorial analysis to verify associations of the outcomes with the ΔE00. |
|
| AH Plus-2mm | Experimental | The objective is evaluate the color change (ΔE00) originated from epoxy resin (AH Plus) endodontic sealer, sectioned 2 mm below cervical level. The ΔE00 will be evaluated using the measurements data obtained in a period between the immediate endodontic treatment versus after 3, 6 and 12 months. The values of ΔE00 obtained for each sealer, cut and time will be analyzed by multifactorial analysis to verify associations of the outcomes with the ΔE00. |
|
| MTA Fillapex-2mm |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| endodontic treatment | Procedure | The operator will remove the pulp inside the tooth, clean, disinfect and shaping the root canals and seal the space with endodontic sealer. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Color change | Color alteration will be evaluated using the measurements obtained in the homologous tooth (without endodontic treatment) versus the measurement obtained from the tooth treated endodontically. Data will be analyzed according to sealer, cut and time | After immediate endodontic treatment versus after 3, 6 and 12 months |
Not provided
Not provided
Inclusion Criteria:
endodontically treated tooth, without intraradicular retainer and fixation;
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Federal University of Pelotas | Pelotas | Rio Grande do Sul | 96015-560 | Brazil |
Not provided
| ID | Term |
|---|---|
| D019553 | Tooth, Nonvital |
| D014075 | Tooth Discoloration |
| ID | Term |
|---|---|
| D003788 | Dental Pulp Diseases |
| D014076 | Tooth Diseases |
| D009057 | Stomatognathic Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D004708 | Endodontics |
| ID | Term |
|---|---|
| D003813 | Dentistry |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective is evaluate the color change (ΔE00) originated from mineral trioxide aggregate (MTA Fillapex) endodontic sealer, sectioned 2 mm below cervical level. The ΔE00 will be evaluated using the measurements data obtained in a period between the immediate endodontic treatment versus after 3, 6 and 12 months. The values of ΔE00 obtained for each sealer, cut and time will be analyzed by multifactorial analysis to verify associations of the outcomes with the ΔE00. |
|