Closed loop technology has been shown to reduce both hypoglycemia and hyperglycemia, as well as reduce glycemic variability. Sensor augmented pump (SAP) therapy means the addition of alerts according to high or low glucose values as well as trend arrows showing actual glucose trends to pump therapy. This Hybrid closed loop (HCL) system provides several additional effects compared to SAP therapy: according to actual and predicted sensor glucose values, the insulin therapy can be adopted automatically by pump: in case of high values (or predicted) more insulin will be administered, in case of low values (or predicted) the insulin infusion will be decreased a suspended and resumed again. So the HCL provides a lot more automatic functions to keep glucose in target compared to SAP.
The aim of the current trial is to compare the SAP-therapy with the hybrid closed loop glucose management in patients with type 1 diabetes at home.
Monocentric, randomized, controlled cross-over safety evaluation study. For the study, 20 subjects per age group (small children 2-<9 years, children/adolescents ≥9-14 years) will be enrolled (total n=40). The study is anticipated to last no longer than 6 months from investigational center initiation to completion of all data entry and monitoring procedures. It is estimated that all subjects will be enrolled into the study within approximately 3 months of study start.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Therapy with Hybrid Closed Loop (HCL) | Experimental | The Intervention is the specific function of the Insulin Pump from Medtronic® with the name "MiniMed® 670G (MMT-1780)" to deliver Insulin as medication. This Medtronic MiniMed 670G Insulin Pump in Auto Mode is an Hybrid closed loop (HCL) system including an Auto Mode function. It provides as intervention several additional effects concerning automatically insulin delivery by pump: e.g. in case of high values (or predicted) - more insulin will be administered automatically, in case of low values (or predicted) - the insulin infusion will be decreased a suspended and resumed again. The patients will wear the pump continuously. |
|
| Sensor Augmented Pump (SAP) therapy | Active Comparator | The Intervention is the specific therapy of the Sensor Augmented Insulin Pump "MiniMed® 670G" (MMT-1780) without Auto Mode. This Medtronic MiniMed 670G Insulin Pump without Auto Mode' is a Sensor Augmented Pump (SAP) therapy and means the addition of alerts according to high or low glucose values as well as trend arrows showing actual glucose trends to pump therapy. The patients will wear the pump also continuously, but have to respond manually after the alarm. There are no automatically steps from the pump. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Medtronic MiniMed 670G Insulin Pump in Auto Mode | Device | This kind of intervention will be part of the intensified insulin therapy for type 1 diabetic patients. The system will help to keep blood glucose in a defined range by automatic assisted adaption of insulin dosing.the HCL provides a lot more automatic functions to keep glucose in target compared to SAP. |
| Measure | Description | Time Frame |
|---|---|---|
| Reduction of Sensor Glucose | Time in Range (% of Sensor Glucose 70-180 mg/dL) (SAP period vs Hybrid Closed loop) | 6 month |
Not provided
Not provided
Inclusion Criteria:
General Inclusion Criteria
At time of screening: Subjects who are 2-14 years are determined by the investigator to be psychologically sound (e.g. no depression, anxiety disorder, traumatic stress disorder) in order to successfully participate in this study
Subject has been diagnosed with type 1 diabetes ≥ 1 year Study-specific inclusion criteria
Subjects will be considered for enrollment in the study if they meet all of the following criteria:
Subjects who are 2-14 years are determined by the investigator to have the appropriate, requisite support (family, caregiver or social network) to successfully participate in this study
Subject is willing to wear the system continuously throughout the study
Subject is willing to perform required sensor calibrations
Total daily dose of Insulin >8 U
Subject has an A1C value < 12.0% (as processed by Laboratory) at time of screening visit
Subject must be on Pump therapy for >3 months prior to Screening
Subject may also be on sensor augmented pump therapy.
If subject has celiac disease it has been adequately treated as proven by Transglutamase-Antibodies in normal range
Exclusion Criteria:
Patients whose vision or hearing does not allow cognition of pump signals and alarms.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Thomas Danne, MD | Diabetes Centre for Children and Adolescents, Kinderkrankenhaus AUF DER BULT | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Kinder - und Jugendkrankenhaus AUF DER BULT | Hanover | 30173 | Germany |
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D016503 | Drug Delivery Systems |
| ID | Term |
|---|---|
| D004358 | Drug Therapy |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Medtronic MiniMed 670G Insulin Pump without Auto Mode | Device | Sensor augmented pump therapy means the addition of alerts according to high or low glucose values as well as trend arrows showing actual glucose trends to pump therapy. There is no automatic adaption of insulin dosing. The patients must respond manually after alarm or according to the trend arrows. |
|
|
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |