The investigational devices are approved intraocular lenses (IOL) intended to be implanted after phacoemulsification in individuals suffering from age-related cataract with the need of cataract surgery. Within the study, three different IOLs will be investigated and separately evaluated. Cataract surgery with IOL implantation will be performed in subjects who have signed an informed consent form. Postoperative examinations will be postoperative refraction, visual acuity, slitlamp examination, and rotation of the IOL within 1 hour, 1 week, 1 month and 4-7 months.
In the Alcon Clareon toric, RayOne EMV toric and PODEYE Toric group, patients receive a toric IOL according to their preoperative astigmatism
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 0° | Experimental | Implantation of an intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impress on axis 0° |
|
| 45° | Experimental | Implantation of an intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impresson axis 45° |
|
| 90° | Experimental | Implantation of an intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impress on axis 90° |
|
| 135° | Experimental | Implantation of an intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impresson axis 135° |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Intraocular Lens Implantation | Device | Implantation of an intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impressinto the capsular bag using an injector, after removing of the human cristalline lens. Implantation of the Alcon Clareon toric and Rayner RayOne EMV toric IOL and PODEYE Toric IOL on the axis according to the steep meridian of the cornea |
| Measure | Description | Time Frame |
|---|---|---|
| Change of axial intraocular lens position | Change in axis position of an intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impress or Alcon Clareon toric or Rayner RayOne EMV toric or PODEYE Toric from end of surgery (baseline axis) to 1 hour, 1 week, 1 month and 4-7 months (end of study visit). The change in axis position will be evaluated with respect to the baseline measurement at the end of surgery. Differences in axis position will be described as rotation in degrees (0 to 360°) | 7 months |
| Measure | Description | Time Frame |
|---|---|---|
| Decentration | Decentration of the intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impress or Alcon Clareon toric or Rayner RayOne EMV toric or PODEYE Toric will be measured with the Casia 2 OCT. Decentration will be described as "Decentration in milimeter" | 7 months |
| Tilt |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Preceding ocular surgery or trauma
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Rupert Menapace, Prof.Dr. | Contact | 0043-1-40400 | - 66300 | rupert.menapace@meduniwien.ac.at |
| Daniel Schartmueller, Dr. | Contact | 0043-1-40400 | 79450 | daniel.schartmueller@meduniwien.ac.at |
| Name | Affiliation | Role |
|---|---|---|
| Rupert Menapace, Prof.Dr. | Medical University Vienna | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Vienna Allgemeines Krankenhaus | Recruiting | Vienna | State of Vienna | 1090 | Austria |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 38951940 | Derived | Schartmuller D, Lisy M, Mahnert N, Schranz M, Danzinger V, Schwarzenbacher L, Pieh S, Abela-Formanek C, Leydolt C, Menapace R. Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens. Eye Vis (Lond). 2024 Jul 2;11(1):25. doi: 10.1186/s40662-024-00393-2. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The study involves 5 different groups. All groups will be investigated seperately.
Alcon Clareon toric group: 130 eyes Rayner RayOne group: 130 eyes Hoya Nanex group: 130 eyes Hoya Vivinex Impress: 120 eyes Rayner RayOne EMV toric group: 120 eyes PODEYE Toric: 120 eyes
Not provided
Not provided
Not provided
Not provided
|
Tilt of the intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impress or Alcon Clareon toric or Rayner RayOne EMV toric or PODEYE Toric will be measured with the Casia 2 OCT. Tilt will be described as "Tilt in degrees at a certain axis" |
| 7 months |
| Anterior chamber depth | The anterior chamber depth (Axial position of the IOL) of the intraocular lens Rayner RayOne or Hoya Nanex or Hoya Vivinex Impress or Alcon Clareon or Rayner RayOne EMV toric or PODEYE Toric will be measured with the Casia 2 OCT after 1 month. The anterior chamber depth will be measured in milimeter | 1 month |
| Best corrected visual acuity (BCVA) | BCVA will be measured at 1 week, 1 month and 4 to 7 months. The BCVA will be described as the minimum angle of resolution (logMar) | 7 months |
| UCIVA in the Alcon Clareon toric and Rayner RayOne EMV toric groups | Uncorrected Intermediate Visual Acuity mono or bilateral | 7 months |
| ID | Term |
|---|---|
| D001251 | Astigmatism |
| ID | Term |
|---|---|
| D012030 | Refractive Errors |
| D005128 | Eye Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D019654 | Lens Implantation, Intraocular |
| ID | Term |
|---|---|
| D054140 | Refractive Surgical Procedures |
| D013508 | Ophthalmologic Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided