Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Universität Tübingen | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of this randomized, controlled single blind study is to compare pulse wave and blood pressure measurements before, during and after exercise ergometry in healthy male subjects.
In a randomized single-blind study design the investigators explore how well blood pressure parameters calculated using a Pulse Transit Time-based method (device: SOMNOtouchTM RESP) match blood pressure parameters measured by a classic upper arm blood pressure cuff (Mobil-O-Graph® PWA) under standardized load conditions (ergometry).
In 30 healthy male subjects (age 18 - 40 years), cardiovascular parameters before, during and after a standardized load on a bicycle ergometer (half-lying position) are recorded with three different devices (Mobil-O-Graph® PWA versus SOMNOtouchTM RESP versus GeTeMed Vitaguard 3100) and compared.
Primary outcome is the difference of the systolic blood pressure values between the devices Mobil-O-Graph® PWA versus SOMNOtouchTM RESP during the three phases.
The Mobil-O-Graph® PWA blood pressure cuff is applied randomized to the arm with the previously determined higher or lower systolic blood pressure mean difference. The subjects are blinded to the results of the measurements during ergometry.
After a pre-rest period of 12 minutes, the subjects are physically strained on the ergometer for 48 minutes (6 minutes loading phase followed by a 2-minute rest phase; 30 watts increase every 8 minutes up to a maximum load of 180 watts), followed by a 12-minute rest period. Measurements are taken every two minutes with the Mobil-O-Graph® PWA; data acquisition with the SOMNOtouchTM RESP and GeTeMed Vitaguard 3100 devices takes place continuously over a total duration of 72 minutes.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Higher Blood Pressure | Experimental | Mobil-O-Graph PWA blood pressure cuff is applied to the upper arm with the previously determined higher systolic blood pressure. Intervention: Ergometry H |
|
| Lower Blood Pressure | Experimental | Mobil-O-Graph PWA blood pressure cuff is applied to the upper arm with the previously determined lower systolic blood pressure. Intervention: Ergometry L |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ergometry H | Other | After a pre-rest period of 12 minutes, the subjects are physically strained on the ergometer for 48 minutes (6 minutes loading phase followed by a 2-minute rest phase; 30 watts increase every 8 minutes up to a maximum load of 180 watts), followed by a 12-minute rest periodmaximum load of 180 watts), followed by a 15-minute post-rest period. Mobil-O-Graph PWA blood pressure cuff is applied to the upper arm with the previously determined higher systolic blood pressure (reference parameter). SOMNOtouchTM RESP and GeTeMed Vitaguard 3100 are accordingly applied to the arm with the previously determined lower systolic blood pressure. |
| Measure | Description | Time Frame |
|---|---|---|
| Difference of the systolic blood pressure | Primary outcome is the difference of the systolic blood pressure values between the devices Mobil-O-Graph® PWA versus SOMNOtouchTM RESP during the three phases | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Measure | Description | Time Frame |
|---|---|---|
| Diastolic Blood Pressure (SOMNOtouchTM RESP) | Diastolic Blood Pressure (mm Hg) measured with the SOMNOtouchTM RESP device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Mean Arterial Blood Pressure (SOMNOtouchTM RESP) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jan Vagedes, MD | ARCIM Institute, Im Haberschlai 7, 70794 Filderstadt, Germany | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| ARCIM Institute | Filderstadt | Baden-Wurttemberg | 70794 | Germany |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Ergometry L | Other | After a pre-rest period of 12 minutes, the subjects are physically strained on the ergometer for 48 minutes (6 minutes loading phase followed by a 2-minute rest phase; 30 watts increase every 8 minutes up to a maximum load of 180 watts), followed by a 12-minute rest periodmaximum load of 180 watts), followed by a 15-minute post-rest period. Mobil-O-Graph PWA blood pressure cuff is applied to the upper arm with the previously determined lower systolic blood pressure (reference parameter). SOMNOtouchTM RESP and GeTeMed Vitaguard 3100 are accordingly applied to the arm with the previously determined higher systolic blood pressure. |
|
Mean Arterial Blood Pressure (mm Hg) measured with the SOMNOtouchTM RESP device |
| Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Pulse Pressure (SOMNOtouchTM RESP) | Pulse Pressure (mm Hg) measured with the SOMNOtouchTM RESP device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Heartrate (SOMNOtouchTM RESP) | Heartrate (beats per minute, bpm) measured with the SOMNOtouchTM RESP device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Oxygen saturation (SpO2, SOMNOtouchTM RESP) | Oxygen saturation (% SpO2) measured with the SOMNOtouchTM RESP device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Pulse-Transit-Time (PTT, SOMNOtouchTM RESP) | Pulse-Transit-Time (PTT, ms) measured with the SOMNOtouchTM RESP device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Systolic Blood Pressure measured with the device Mobil-O-Graph® PWA | Systolic Blood Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Diastolic Blood Pressure measured with the device Mobil-O-Graph® PWA | Diastolic Blood Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Mean Arterial Blood Pressure measured with the device Mobil-O-Graph® PWA | Mean Arterial Blood Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Pulse Pressure measured with the device Mobil-O-Graph® PWA | Pulse Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Heartrate (Mobil-O-Graph® PWA) | Heartrate (beats per minute, bpm) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Puls Pressure Amplification (Mobil-O-Graph® PWA) | Puls Pressure Amplification measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Stroke Volume (Mobil-O-Graph® PWA) | Stroke Volume (ml) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Cardiac output (Mobil-O-Graph® PWA) | Cardiac output (l/min) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Vascular Resistance (Mobil-O-Graph® PWA) | Vascular Resistance (s*mmHg/ml) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Cardiac Index (Mobil-O-Graph® PWA) | Cardiac Index (l/min*1/m2) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Augmentation Pressure (Mobil-O-Graph® PWA) | Augmentation Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Reflection Coefficient (Mobil-O-Graph® PWA) | Reflection Coefficient (%) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Pulse Wave Velocity (PWV) (Mobil-O-Graph® PWA) | Pulse Wave Velocity (PWV, m/s) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Systole Time (Mobil-O-Graph® PWA) | Systole Time (s) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Tmax-forward (Mobil-O-Graph® PWA) | Tmax-forward (s) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Tmax-backward (Mobil-O-Graph® PWA) | Tmax-backward (s) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Forward Pressure (Mobil-O-Graph® PWA) | Forward Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Backward Pressure (Mobil-O-Graph® PWA) | Backward Pressure (mmHg) measured with the Mobil-O-Graph® PWA device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Pulse Transit Time (GeTeMed Vitaguard 3100) | Pulse Transit Time (PTT, ms) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Perfusion Index (GeTeMed Vitaguard 3100) | Perfusion Index (PI) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| Peak to Peak Time (PPT) (GeTeMed Vitaguard 3100) | Peak to Peak Time (PPT, ms) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| SlopeInW1 (GeTeMed Vitaguard 3100) | SlopeInW1 measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| SlopeInW2 (GeTeMed Vitaguard 3100) | SlopeInW2 measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| SlopeInW3 (GeTeMed Vitaguard 3100) | SlopeInW3 measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| SlopeInW4 (GeTeMed Vitaguard 3100) | SlopeInW4 measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| StiffnessIndex (GeTeMed Vitaguard 3100) | StiffnessIndex measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| ReflectionIndex (GeTeMed Vitaguard 3100) | ReflectionIndex measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| TimeTX (GeTeMed Vitaguard 3100) | TimeTX (ms) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| TimeTY (GeTeMed Vitaguard 3100) | TimeTY (ms) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| QuotTYTX (GeTeMed Vitaguard 3100) | QuotTYTX measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| AreaAX (GeTeMed Vitaguard 3100) | AreaAX measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| AreaAY (GeTeMed Vitaguard 3100) | AreaAY measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| QuotAYAX (GeTeMed Vitaguard 3100) | QuotAYAX measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| AreaAV (GeTeMed Vitaguard 3100) | AreaAV measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| AreaAW (GeTeMed Vitaguard 3100) | AreaAW measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| QuotAWAV (GeTeMed Vitaguard 3100) | QuotAWAV measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| QuotTVTW (GeTeMed Vitaguard 3100) | QuotTVTW measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| TimeTV (GeTeMed Vitaguard 3100) | TimeTV (ms) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| TimeTW (GeTeMed Vitaguard 3100) | TimeTW (ms) measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| MinT1 (GeTeMed Vitaguard 3100) | Minimum of the pulse wave measured with the GeTeMed Vitaguard 3100 device at the beginning of the first peak | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| MinT2 (GeTeMed Vitaguard 3100) | Minimum of the pulse wave measured with the GeTeMed Vitaguard 3100 device at the beginning of the second peak | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| MaxT1 (GeTeMed Vitaguard 3100) | Maximum of the pulse wave measured with the GeTeMed Vitaguard 3100 device at the maximum of the first peak | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| MaxT2 (GeTeMed Vitaguard 3100) | Maximum of the pulse wave measured with the GeTeMed Vitaguard 3100 device at the maximum of the second peak | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |
| QuotHRRespRate (GeTeMed Vitaguard 3100) | Quotient of heart and respiratory rates measured with the GeTeMed Vitaguard 3100 device | Physiological parameters are measured continuously (SOMNOtouchTM RESP) and every 2 min (Mobil-O-Graph©PWA) for a total duration of 72 min |