The MARIA breast imaging system is a Conformité Européenne (CE)-marked radio-frequency (RF) medical imaging device. The system employs an electromagnetic imaging technique that exploits the dielectric contrast between normal and cancerous tissues. The performance and imaging characteristic differences between the M5 and M6 versions of MARIA are not yet well demonstrated in the clinical environment, particularly with regards to cysts. The evaluation of some aspects of this potentially important new technology will occur in this comparative technical study. Further, the dielectric constant of cyst fluid is currently not well understood and obtaining readings from aspirated cyst fluid in applicable patients will be attempted.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Main MARIA scan visit | Other | For Arm 1, participants will be identified in clinic as having a suitable symptomatic breast and approached about the study. They will have the study design explained to them and will be informed that they are under no obligation to participate. Arm 1 participants will receive study information that they will be sent home with and informed that they will be approached via a telephone call in 2-3 days (or the closest working day to that date) to enquire if they would like to schedule an appointment for the study visit. If so, this will be scheduled to occur around 7 days from the date of the phone call. |
|
| Same-day MARIA scan visit | Other | For Arm 2, participants will be identified in clinic as having a suitable symptomatic breast and approached about the study. They will have the study design explained to them and will be informed that they are under no obligation to participate. Arm 2 participants will receive study information and as much time as possible to consider their involvement with the study (at least 1 hour). If the patient agrees to participate, they will be scheduled to have their MARIA scans at a time that suits their commitments that day. This arm also includes the 2b group, who can optionally consent to a dielectric constant reading of their routinely-aspirated cyst fluid before this is disposed of as per usual site process. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| MARIA scan | Device | The MARIA breast imaging system comprises of a scanning unit, housed under a patient bed. The scanning unit houses a hemispherical array, into which varying sizes of insert are fitted to ensure a close fit to the breast. The patient lies prone on the bed with their breast pendulous through an aperture in the bed and the scanning unit is risen to meet the breast. The fit is non-compressing and the scanner does not use ionising radiation. |
| Measure | Description | Time Frame |
|---|---|---|
| Establish the presence or absence of a difference in the MARIA(R) outputs obtained with M5 and M6 when the participants is not moved between scans and when they are moved between scans | This will be established from Arm 1 and Arm 2 by scanning the participant between both versions of the MARIA system. As has been investigated in-house with healthy volunteers, the patient will take part in a series of scans that will involve them remaining stationary between scans, and moving between scans. The differences between these images will be analysed, using the known palpable lesion in the breast as a landmark. | Up to 12 weeks |
| Establish the presence or absence of a difference between MARIA(R) outputs on the same device when the participant is stationary between scans and when they are moved between scans | This will be established from Arm 1 and Arm 2 by scanning the participant on each separate version of the MARIA system. As has been investigated in-house with healthy volunteers, the patient will take part in a series of scans that will involve them remaining stationary between scans, and moving between scans. The differences between these images will be analysed, using the known palpable lesion in the breast as a landmark. | Up to 12 weeks |
| Measure the dielectric constant of aspirated cyst fluid and any variance between cyst type | This will be established from Arm 2b by recording the dielectric constant of the aspirated cyst fluid as soon as possible after aspiration using a dielectric probe. No cysts will be aspirated exclusively for this procedure and fluid will be disposed of as per usual site practice once the recording has taken place. Each cyst fluid sample will have its dielectric constant recorded three times and recorded in the provided software before disposal. | Up to 12 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Assess the diagnostic accuracy of both the M5 and M6 versions of the MARIA system in identifying lesions of the breast, including benign lesions such as cysts | This will be established from Arm 1 and 2 by using a combination of reader results from clinician reads performed by the site team with all available clinical information and blind reads performed in house which will utilise no clinical information. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Further:
The device is currently registered for the scanning of female human breast tissue only
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Thirlestaine Breast Centre, Gloucestershire Hospitals NHS Foundation Trust | Cheltenham | GL53 7AS | United Kingdom |
Data collected will be anonymised
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D047688 | Breast Cyst |
| D009369 | Neoplasms |
| D001943 | Breast Neoplasms |
| ID | Term |
|---|---|
| D003560 | Cysts |
| D001941 | Breast Diseases |
| D012871 | Skin Diseases |
| D017437 | Skin and Connective Tissue Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Up to 12 weeks |
| Understand participant acceptability of the MARIA scan and obtain feedback on patient experience: questionnaire | This will be established from Arm 1 and 2 by asking the participant to complete a questionnaire of their experience after their participation in either of the two main study arms. The questionnaire comprises of 8 questions and a free-text box for any additional comments. The first two questions ask a participant to pick one of 5 options, from very easy to very difficult or very comfortable to very uncomfortable. The next even questions are Yes or No questions, with options for the participant to answer these as "Not sure" or "Not applicable" as appropriate. The questionnaire then ends with a free-text box for feedback. | Up to 12 weeks |
| D009371 |
| Neoplasms by Site |