A prospective, multi-centre, objective performance criteria clinical trial to evaluate the safety and efficacy of Artery Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. for the thoracic aortic dissection involving the aortic arch.
This clinical trial was conducted in a qualified clinical trial institution. Investigators will use Artery Stent Graft System manufactured by Lifetech Scientific (Shenzhen) Co., LTD. to treat patients with thoracic aortic dissection involving the aortic arch. This is a Prospective, Multi-center, Objective Performance Criteria Clinical Trial. It is expected to submit to the ethics committee of the lead unit for review in Sep 2018, and complete the implantation of 150 patients in 18 centres nationwide within 12 months, and interim follow-up was conducted before discharge, 30 days after surgery, 6 months after surgery and 12 months after surgery, long-term follow-up will be performed at 24 months postoperatively, 36 months postoperatively, 48 months postoperatively and 60 months postoperatively.
This trial will evaluate whether the device reached the primary safety endpoint and primary efficacy endpoint through two primary endpoint indicators: the incidence of major adverse events (MAE) within 30 days and the success rate of aortic dissection treatment 12 months after surgery.
This trail will evaluate whether the device reached the secondary safety endpoint and efficacy endpoint through several secondary endpoint indicators:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intervention arm | Experimental | Participants will be treated with Artery Stent Graft System Intervention: Device: Artery Stent Graft System |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Artery Stent Graft System | Device | The Artery Stent Graft System consists of Ankura pro Aorta Stent Graft System along with Longuette Aortic Branch Stent Graft System for chimney technique in the aim of revascularization of aorta branches.The Ankura pro aorta stent graft and Longuette Aortic Branch Stent Graft System are pre-assembled within delivery system. During the operation, the stent graft was delivered to the target lesion location of the vascular real cavity through a delivery system, which was accurately positioned and released to isolate the ruptured opening of aortic dissection, block the continuous flow of blood into the false cavity of the dissection, and avoid further tearing or even rupture of the dissection. |
| Measure | Description | Time Frame |
|---|---|---|
| The treatment success rate of aortic dissection at 12 months post-implant | Assessment of the rate of successful disease treatment defined as immediate technical success and freedom from secondary intervention at 12 months of follow-up. Technique success means delivery system is successfully transported to the predetermined position, both of aorta stent graft and aortic branch stent graft successfully expanded and delivery system withdraw successfully.No type I/III endoleak at the end of operation, no conversion to open surgery. (Adjuvant Interventions during operation do not defined as technical failure.) | 12 months after surgery |
| Incidence of no major adverse events (MAE) occurred at 30 days post-implant | Major Adverse events (MAE) are defined as aortic dissection related mortality, ischemic stroke, and paraplegia. | 30 days after surgery |
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of all-cause death | 30 days,6 months, 12 months and 2-5 years after surgery | |
| Incidence of Aortic dissection dissection-related death | 30 days,6 months, 12 months and 2-5 years after surgery |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Chang Shu, professor | Central South University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Fuwai hospital, Chinese Academy of Medical Sciences | Beijing | Beijing Municipality | 100037 | China | ||
| Chinese PLA General Hospita |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 38569918 | Derived | Shu C, Wan Z, Luo M, Fang K, Hu J, Zuo J, Li X, Li Q, He H, Li X. Mid-term results of a prospective study for aortic dissection with a gutter-plugging chimney stent graft. Eur J Cardiothorac Surg. 2024 May 3;65(5):ezae135. doi: 10.1093/ejcts/ezae135. | |
| 37198293 | Derived | Liu Y, Fang K, Luo MY, Xiao ZH, Yang P, Lu C, Zhang Y, Wang HY, Xie Y, Xu ZY, Zhang HW, Shu C, Hu J. Single-Center Preliminary Experience with Gutter-Plugging Chimney Stent-Graft for Aortic Dissection. Cardiovasc Intervent Radiol. 2023 Jun;46(6):703-712. doi: 10.1007/s00270-023-03444-8. Epub 2023 May 17. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Incidence of Serious Major Adverse Event(SAE) | 30 days,6 months, 12 months and 2-5 years after surgery |
| Incidence of device related adverse events(AE) | 30 days,6 months, 12 months and 2-5 years after surgery |
| Incidence of left upper limb ischemia | 30 days,6 months, 12 months and 2-5 years after surgery |
| Incidence of I/III type endoleaks | 30 days,6 months, 12 months and 2-5 years after surgery |
| Incidence of graft migration | 30 days,6 months, 12 months and 2-5 years after surgery |
| Branching vascular patency rate | 30 days,6 months, 12 months and 2-5 years after surgery |
| Incidence of Thoracic aortic dissection -related surgical conversion or re-intervention | 30 days,6 months, 12 months and 2-5 years after surgery |
| Beijing |
| Beijing Municipality |
| China |
| The Frist Hospital of Lanzhou University | Lanzhou | Gansu | China |
| LIU ZHOU WORKER'S HOSPITAL,Fourth Affiliated Hospital of Guangxi Medical University | Liuzhou | Guangxi | China |
| The second affiliated hospital of Harbin medical university | Harbin | Heilongjiang | China |
| Henan Provincial People's Hospital | Zhengzhou | Henan | China |
| The Central Hospital of Wuhan | Wuhan | Hubei | China |
| Tongji Hospital,Tongji Medical College of Huazhong University of Science&Technology | Wuhan | Hubei | China |
| The Second Xiangya Hospital of Central South University | Changsha | Hunan | China |
| Nanjing Drum Tower Hospital (Nanjing Gulou Yi Yuan), the Affiliated Hospital of Nanjing University Medical School | Nanjing | Jiangsu | China |
| The first affiliated hospital of soochow university | Suzhou | Jiangsu | China |
| The Second Affiliated Hospital Of Nanchang University | Nanchang | Jiangxi | China |
| The First Hospital of Jilin University | Changchun | Jilin | China |
| Shandong Provincial Hospital | Jinan | Shandong | China |
| Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine | Shanghai | Shanghai Municipality | China |
| Zhongshan Hospital, Fudan University | Shanghai | Shanghai Municipality | China |
| Xijing Hospital, The Fourth Military Medical University | Xi’an | Shanxi | China |
| West China hospital of sichuan university | Chengdu | Sichuan | China |
| Tianjin Chest Hospital | Tianjin | Tianjin Municipality | China |
| Tianjing Medical University General Hospital | Tianjin | Tianjin Municipality | China |
| The first people's hospital of yunnan province | Kunming | Yunnan | China |
| ID | Term |
|---|---|
| D000094629 | Dissection, Thoracic Aorta |
| D001018 | Aortic Diseases |
| D000784 | Aortic Dissection |
| ID | Term |
|---|---|
| D000094665 | Dissection, Blood Vessel |
| D000783 | Aneurysm |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D000094683 | Acute Aortic Syndrome |
Not provided
Not provided