Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Introduction: Postural control is a crucial factor for maintaining balance while standing and walking. The shoe has a role to play in postural stability.
Objectives: To evaluate the static balance of subjects when barefoot and when using three types of footwear with their eyes closed or open.
Material and methods:
Each participant was asked to focus on a white mark 2 cm in diameter, positioned on a screen 2 m in front of them at eye level. This was done to standardize the data collection and minimize any variation in postural stability caused by changes in the visual field. Each participant was asked to remain in this position for a period of 30 seconds, while the data was collected. Three repetitions were made for each condition to obtain an average value. The condition on footwear and open / closed eyes was randomized to reduce the learning effect. On the other hand to reduce fatigue, each participant was allowed to rest for 5 minutes between shoe changes.
The size of the sample was calculated with the software of the Clinical Epidemiology and Biostatistics Unit. Complexo Hospitalario Universitario de A Coruña. University of A Coruña (www.fisterra.com). The estimated sample size estimated was calculated to be at least 16 subjects.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Stabilometry | Other | The Podoprint pressure platform was used as a measuring device. The Podoprint platform is a low profile floor platform consisting of 1.4 sensors / cm2 with a sampling frequency of 40Hz. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Stabilometry | Device | To evaluate the static balance of subjects when barefoot and when using three types of footwear with their eyes closed or open. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Stroke length | Length traveled by the pressure center (CoP), forming a line called oscillatory ball. In mm. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |
| Stroke surface | Area of the smallest ellipse able to encompass the oscillating ball. In mm. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |
| Relationship between Length / surface | Value resulting from the relationship between the two previous measures. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |
| Average swing speed | Average speed that reaches the displacement of the center of pressures. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |
| Lateral velocity | Average speed of oscillation in its axis of ordinates. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |
| Forward speed | Average oscillation speed on its abscissa axis. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |
| Average displacement in the X axis | Average of the displacements made by the center of pressures in the axis of ordinates. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jose Sanchez Saez, Podólogo | Universidade da Coruña | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| ClÃnica López del Amo | Murcia | 30008 | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31208123 | Derived | Sanchez-Saez JM, Palomo-Lopez P, Becerro-de-Bengoa-Vallejo R, Calvo-Lobo C, Losa-Iglesias ME, Lopez-Del-Amo-Lorente A, Lopez-Lopez D. Stability of Three Different Sanitary Shoes on Healthcare Workers: A Cross-Sectional Study. Int J Environ Res Public Health. 2019 Jun 16;16(12):2126. doi: 10.3390/ijerph16122126. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D013180 | Sprains and Strains |
| ID | Term |
|---|---|
| D014947 | Wounds and Injuries |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 30 seconds |
| Average displacement on the Y axis | Average of the displacements made by the center of pressures on the abscissa axis. The Podoprint pressure platform was used as a measuring device. Quantitative variable | 30 seconds |