The primary objective of COGNI-CRT is to assess whether Cardiac Resynchronisation Therapy (CRT) can improve cognitive function in patients with systolic HF (LVEF ≤35%), when compared to a control group of patients implanted with an Implantable Cardioverter-Defibrillator (ICD) or a permanent pacemaker (PPM) with systolic HF (LVEF ≤35%).
This clinical investigation is a prospective, single-centre cohort study. Each participant will be followed for 6 months. The study will collect data over 3 years; 2.5 years for enrolment and 6 months until the last participant completes the last 6-month follow-up visit.
N.B: COGNI-CRT does NOT affect the patient's care pathway - the patients who will be selected for participation are those who have already been referred for the device implant. The ONLY difference to the patient's care pathway caused by COGNI-CRT is the addition of a battery of cognitive function tests, which involves asking the patient questions and asking them to complete questionnaire-like cognitive tests.
NTpro-BNP levels, NYHA classification and LVEF will be measured prior to device implantation and at 6-months post-implant to assess the device's impact on the participant's heart failure (and CRT response). N.B: NT-proBNP, NYHA classification and LVEF are all parts of the patient's standard care pathway, COGNI-CRT is just utilising the data collected as part of the investigation.
The main study arm and control group allows COGNI-CRT to assess 3 potential outcomes for patients with severe HF (LVEF <35%):
Purpose:
The purpose of this clinical investigation is to assess whether cardiac resynchronisation therapy (CRT) can improve cognitive function in patients with systolic heart failure (Left Ventricular Ejection Fraction (LVEF) ≤35%), when compared to a control group of patients implanted with an implantable cardioverter-defibrillator (ICD) or permanent pacemaker (PPM) with systolic heart failure (LVEF ≤35%).
Design:
This clinical investigation is a prospective, single-centre cohort study. The study will be conducted at the Royal Cornwall Hospital Trust (RCHT) in Cornwall, England. Subjects will be followed for 6 months.
Cognitive performance will be assessed in patients pre- and post-CRT implant (Group A). An ICD and PPM control group (Group B) will also be assessed using the same battery of cognitive function tests to ensure any difference in cognitive function which is identified between pre- and post- CRT implant is due to the CRT therapy, and not due to a placebo effect (which can be especially powerful with implanted devices) or due to a learning effect (i.e. patients tested on the second occasion might improve their scores because they have had more practice).
N.B: COGNI-CRT does NOT affect the patient's care pathway - the patients who will be selected for participation are those who have already been referred for the device implant. The ONLY difference to the patient's care pathway caused by COGNI-CRT is the addition of a battery of cognitive function tests, which involves asking the patient questions and asking them to complete questionnaire-like cognitive tests.
LVEF, NT-proBNP and New York Heart Association (NYHA) classification data which is collected prior to device implantation and at 6-months post-implant will be utilised for analysis to measure response to CRT and to assess difference between the main arm and control group.
Arms in the study will be:
Objectives:
Primary objective: To assess whether CRT can improve cognitive function in patients with systolic heart failure (LVEF ≤35%), when compared to a control group of patients implanted with an ICD or PPM with systolic heart failure (LVEF ≤35%).
Secondary Objectives:
Subject Population:
The subject population enrolled in this investigation will comprise of male and female patients aged 20-89 years old. These subjects are patients who are willing to provide informed consent and meet the specific eligibility criteria. A minimum of 198 participants will be enrolled in this investigation.
Data for this study will be collected at:
Devices Used:
Implanted CRT-P, CRT-D, ICD and PPM devices may include Biotronik, Boston Scientific, Medtronic and St Jude Medical.
Patient Screening:
Patients who are referred to RCHT for CRT, ICD or PPM implantation with systolic heart failure (LVEF ≤35%) will be screened prior to Pre-Assessment by the clinical team. Prospective patients will be afforded sufficient time to consider participation in COGNI-CRT.
Cognitive Tests Used to Evaluate Cognitive Function:
To be Performed Only At Pre-Assessment:
Test of Premorbid Functioning (TOPF): TOPF provides the participant with a list of 70 words that have atypical grapheme to phoneme translations. The participant must attempt to read the list aloud so pronunciation of the words can be assessed. This tests IQ and memory as the participant must be familiar with the words, rather than being able to spell out a word they do not know. It takes approximately 10 minutes to complete
To be Performed at Pre-Assessment and at the Post-Implant 6-Month Device Follow-Up Visit:
Hospital Anxiety and Depression Scale (HADS): The test consists of 14 multiple-choice questions, each attempting to ascertain about the frequency the participant has felt a certain symptom within the last 7 days. There are 4 answers to choose from which range from suffering from the symptom "nearly all the time" to "not at all" and are graded 0-3 depending on the participant's answer.
Repeatable Battery for the Assessment of Neuropsychological Status (RBANS): Consisting of 12 sections, to evaluate 5 types of cognitive function: immediate memory; visuospatial/ constructional; attention; language and delayed memory.
Frontal Assessment Battery (FAB): The test has 6 neuropsychological tasks which involve asking the participant questions, for example "In what way are a banana and an orange alike?", and learning simple actions in response to hand taps or movements.
Trail Making Test (TMT) Parts A & B: Both parts of TMT involve circles dotted over a piece of paper, the circles for Part A are marked with the numbers 1 - 25 and the patient must draw a line connecting the numbers in ascending order, i.e. "1-2-3-4-5-6…" etc. Part B involves numbers and letters dotted around the page, from 1-13 and from A-L. The patient must connect the numbers and letters in ascending order, alternating between numbers and letters, i.e. "1-A-2-B-3-C…" etc
Response to CRT Measures will be measured prior to device implantation and at the 6-month follow-up device follow-up clinic:
LVEF: LVEF will be measured prior to device implant to assess the patient's heart function, and at the Post-Implant 6-Month Device Follow-Up Visit.
NT-proBNP: NT-proBNP levels from the patient's routine blood tests prior to device implantation and at the Post-Implant 6-Month Device Follow-Up Visit where blood testing is routine for heart failure patients every 6 months.
NYHA: A NYHA scale assessment will be performed during the screening clinics prior to device implant, and at the Post-Implant 6-Month Device Follow-Up Visit using the standardised NYHA questions designed for the purpose of this trial.
N.B: The above 3 tests (LVEF, NT-proBNP and NYHA classification) are performed routinely as part of the patient standard care pathway for heart failure, and this data will be utilised for analysis in this trial. The tests are NOT performed for the purpose of COGNI-CRT.
Device Optimisation:
At the post-implant 6-week device follow-up check, all efforts will be made to ensure the device is optimised as much as is possible, and the patient listed for MDT if problems are encountered to attempt to resolve problems.
Data Analysis:
Data will be tested for normality. Tests for group differences will be used to compare cognitive function between patients before and after CRT implant, and in the control group before and after ICD or PPM implant. Tests for group differences will also be used in comparison of the LVEF values, BNP results, NYHA classification, QRS duration, percentage biventricular pacing and BP measurements. Sample size calculations have estimated the required CRT sample size to power the study to be 99 participants (with a 95% confidence interval and a 5% margin of error). The expectation is for 99 patients to sign the informed consent and complete follow-up = 99 CRT participants. The control group will aim to enrol a similar figure to the main study group, a further 99 ICD and PPM participants. 99 CRT patients + 99 ICD or PPM patients = 198 patients are expected to be enrolled and complete the study.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| CRT: Main Arm | Cardiac Resynchronisation Therapy (CRT): Main Arm ~98 participants Prior to CRT Implantation & Post-Implant 6-Month Device Follow-Up Clinic: - Battery of 5 questionnaire-based cognitive tests, including the Test of Premorbid Functioning, Repeatable Battery for the Assessment of Neuropsychological Status, Hospital Anxiety and Depression Scale, Frontal Assessment Battery and Trail Making Test Part A and B Please note, the Test of Premorbid Functioning will only be performed ONCE at Pre-Assessment as results reflect IQ prior to disease onset. |
| |
| ICD and PPM: Control Arm | Implantable Cardioverter-Defibrillator (ICD) and Permanent Pacemaker (PPM): Control Arm ~98 participants Prior to ICD or PPM Implantation & Post-Implant 6-Month Device Follow-Up Clinic: - Battery of 5 questionnaire-based cognitive tests, including the Test of Premorbid Functioning Repeatable Battery for the Assessment of Neuropsychological Status, Hospital Anxiety and Depression Scale, Frontal Assessment Battery and Trail Making Test Part A and B Please note, the Test of Premorbid Functioning will only be performed ONCE at Pre-Assessment as results reflect IQ prior to disease onset. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Repeatable Assessment of Neuropsychological Status | Diagnostic Test | Cognitive Function Test (Questionnaire-based) |
|
| Measure | Description | Time Frame |
|---|---|---|
| Change in cognitive function at 6 months post-implant | Measured by the use of a 5-stage cognitive battery test | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Change in left ventricular ejection fraction (LVEF) at 6 months | Measured by transthoracic echocardiogram (TTE) | 6 months |
| Change in N-terminal pro-B-type natriuretic peptide (NT-proBNP) Test at 6 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Heart failure patients (left ventricular ejection fraction (LVEF) <35%) receiving an Cardiac Implantable Electronic Device (CIED), including Cardiac Resynchronisation Therapy (CRT), an Implantable Cardioverter Defibrillator (ICD) or a Permanent Pacemaker (PPM).
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Hannah Ford, BSc (Hons) | Royal Cornwall Hospital NHS Trust | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Royal Cornwall Hospital NHS Trust | Truro | Cornwall | TR13LQ | United Kingdom |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Hospital Anxiety and Depression Scale | Diagnostic Test | Cognitive Function Test (Questionnaire-based) |
|
|
| Frontal Assessment Battery | Diagnostic Test | Cognitive Function Test (Questionnaire-based) |
|
|
| Trail Making Test Part A and B | Diagnostic Test | Cognitive Function Test (Questionnaire-based) |
|
|
| Test of Premorbid Functioning | Diagnostic Test | Cognitive Function Test (Questionnaire-based) |
|
|
Measured by a NT-proBNP blood test.
| 6 months |
| Change in New York Heart Association (NYHA) Functional Classification | Measured via standardised assessment for all participants | 6 months |
| ID | Term |
|---|---|
| D060825 | Cognitive Dysfunction |
| D054143 | Heart Failure, Systolic |
| D006333 | Heart Failure |
| D018487 | Ventricular Dysfunction, Left |
| ID | Term |
|---|---|
| D003072 | Cognition Disorders |
| D019965 | Neurocognitive Disorders |
| D001523 | Mental Disorders |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D018754 | Ventricular Dysfunction |
Not provided
Not provided