Not provided
Not provided
Not provided
Not provided
Terminated early after the interim analysis. It was deemed unethical to offer self-monitored blood glucose to this high risk population
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| London Ambulance Service | OTHER |
Not provided
Not provided
Not provided
This study aims to assess the impact of real-time continuous glucose monitoring on the frequency, duration, awareness and severity of hypoglycaemia in people with type 1 diabetes and a recent history of severe hypoglycaemia, compared to usual care.
Type 1 diabetes (T1DM), which affects 300,000 in the UK, is characterised by autoimmune destruction of the pancreatic beta cells, leading to absolute deficiency of insulin. Management of T1DM requires exogenous insulin administration, aiming for glucose concentrations as close to physiological values as possible. Intensive management of T1DM improves glucose control and reduces the risk of microvascular diabetes complications and cardiovascular disease1. In the UK diabetes consumes more than 10% of the National Health Service budget 2 and in the USA a relatively greater amount is spent on type 1 compared with type 2 diabetes (8.6% of the diabetes budget compared with 5.6% of diabetes prevalence)3. Medication and insulin pump therapy accounts for less than 10% of diabetes expenditure with the majority of costs incurred in the treatment of complications4.
Optimal control remains challenging to achieve and intensive insulin treatment increases the risk of severe hypoglycaemia, with lower glucose values also associated with an increased frequency and severity of moderate hypoglycaemia5, 6. Severe hypoglycaemia is defined as any episode of hypoglycaemia requiring the assistance of a third party actively to treat. Hypoglycaemia is associated with morbidity and even mortality, and places a financial burden on health systems.
Severe hypoglycaemia costs £13million per year in NHS costs7. Between 4 and 10% of deaths in people with type 1 diabetes are attributed to hypoglycaemia and the risk of severe hypoglycaemia increases 6-fold in people with impaired awareness of hypoglycaemia. Avoidance of hypoglycaemia is associated with restoration of hypoglycaemia awareness and this may be enabled by the use of continuous glucose monitoring.
In type 1 diabetes real-time continuous glucose monitoring (CGM) improves overall glucose control in all age groups when used continuously, reduces hypoglycaemia in people with an HbA1c <7.0%, and may reduce severe hypoglycaemia8-10.
The predictive Low-Glucose suspend (PLGS) feature in sensor augmented insulin pumps (SAP) automatically reduces insulin delivery when trends in CGM glucose concentrations predict future hypoglycaemia, and significantly reduces hypoglycaemia without rebound hyperglycaemia compared to SAP without PLGS11.
In England continuous glucose monitoring is supported by NICE for people with type 1 diabetes who are willing to commit to using it at least 70% of the time and to calibrate it as needed, and who have any of the following despite optimised use of insulin therapy and conventional blood glucose monitoring12:
Addressing severe hypoglycaemia, reducing the risk of further episodes and acting promptly to optimise hypoglycaemia awareness are critical in people at high risk.
Continuous subcutaneous insulin pump therapy is supported for adults and children over 12 with type 1 diabetes in whom attempts to achieve target haemoglobin A1c (HbA1c) with multiple daily injections (MDI) have resulted in disabling hypoglycaemia or HbA1c levels have remained high (8.5% [69 mmol/mol] or above) despite high level care12.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Continuous Glucose Monitoring (CGM) | Experimental | The RT CGM group will receive a Dexcom G6 transmitter and sensors, as well as a structured education refresher focusing on hypoglycaemia avoidance, recognition, and management. |
|
| Self Monitoring Blood Glucose (SMBG) | No Intervention | The SMBG group will additionally undergo blinded CGM at weeks 1 and 2, weeks 4 to 6 and weeks 9 to 12 using the Dexcom G6 system. Participants in this group will be shown how to insert the Dexcom G6 at the first clinic visit and sensors provided so they can do this at home. | |
| Continuous Subcutaneous Insulin Infusion (CSII) | Experimental | All participants will be re-consented with the choice to continue using RT-CGM for a further 16 weeks or be re-randomised to either receive the Tandem t:slim X2 insulin pump or RT-CGM. Participants randomised to the Tandem t:slim X2 group will be proficiently trained to safely use the Tandem t:slim X2 insulin pump. All participants (Tandem t:slim X2 and RT-CGM) will be provided with Dexcom G6 real time CGM transmitters and sensors for the 16-week second extension phase. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dexcom G6 CGM | Device | Commercially available Dexcom G6 Continuous Glucose Monitoring |
|
| Measure | Description | Time Frame |
|---|---|---|
| Time Spent in Hypoglycaemia | Percentage time spent in hypoglycaemia (<3.0mmol/L, 55mg/dL) | 12 weeks |
Not provided
Not provided
PRE-REGISTRATION EVALUATIONS
INCLUSION CRITERIA
EXCLUSION CRITERIA
WITHDRAWAL CRITERIA
Participants will be withdrawn if their ability to give informed consent is impaired. Participants will also be withdrawn, at the chief investigators discretion, if glucose control is negatively impacted by the use of either intervention.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Nick Oliver | Imperial College London | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Imperial College Clinical Research Facility | London | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31655586 | Derived | Avari P, Ramli R, Reddy M, Oliver N, Fothergill R. Rationale and protocol for the Assessment of Impact of Real-time Continuous Glucose Monitoring on people presenting with severe Hypoglycaemia (AIR-CGM) study. BMC Endocr Disord. 2019 Oct 26;19(1):110. doi: 10.1186/s12902-019-0439-3. |
| Label | URL |
|---|---|
| NICE Guidelines | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Once participants were enrolled they were randomised to either real-time CGM (intervention) or self-monitoring of blood glucose (standard care) for 12 weeks.
Recruitment was undertaken in collaboration with the London Ambulance Service. Participants were identified following an episode of severe hypoglycaemia. Following any questions, London Ambulance Services and Emergency Departments obtained verbal consent to share details with study investigators, and sent details to principal investigator through a secure website (NHS.net account). Prrticipants had to be enrolled within two weeks of the severehypoglycaemia episode.
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Continuous Glucose Monitoring (CGM) | The RT CGM group will receive a Dexcom G6 transmitter and sensors, as well as a structured education refresher focusing on hypoglycaemia avoidance, recognition, and management. Dexcom G6 CGM: Commercially available Dexcom G6 Continuous Glucose Monitoring |
| FG001 |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Aug 3, 2018 |
Not provided
Randomised open-label parallel group study
Not provided
Not provided
Not provided
Not provided
| Tandem t:slim X2 Insulin Pump | Device | sensor augmented insulin pump with predictive low glucose suspend |
|
| Self Monitoring Blood Glucose (SMBG) |
The SMBG group will additionally undergo blinded CGM at weeks 1 and 2, weeks 4 to 6 and weeks 9 to 12 using the Dexcom G6 system. Participants in this group will be shown how to insert the Dexcom G6 at the first clinic visit and sensors provided so they can do this at home. |
| COMPLETED |
|
| NOT COMPLETED |
|
Baseline demographics are based on the n=30 that completed the study
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Continuous Glucose Monitoring (CGM) | The RT CGM group will receive a Dexcom G6 transmitter and sensors, as well as a structured education refresher focusing on hypoglycaemia avoidance, recognition, and management. Dexcom G6 CGM: Commercially available Dexcom G6 Continuous Glucose Monitoring |
| BG001 | Self Monitoring Blood Glucose (SMBG) | The SMBG group will additionally undergo blinded CGM at weeks 1 and 2, weeks 4 to 6 and weeks 9 to 12 using the Dexcom G6 system. Participants in this group will be shown how to insert the Dexcom G6 at the first clinic visit and sensors provided so they can do this at home. |
| BG002 | Total | Total of all reporting groups |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Median | Inter-Quartile Range | years |
| |||||||||||||||
| Sex: Female, Male | Count of Participants | Participants |
| ||||||||||||||||
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
| ||||||||||||||||
| Region of Enrollment | Number | participants |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Time Spent in Hypoglycaemia | Percentage time spent in hypoglycaemia (<3.0mmol/L, 55mg/dL) | Participants who had sufficient data were included in analysis of primary outcome | Posted | Median | Inter-Quartile Range | percentage time | 12 weeks |
|
|
|
1 year Each participant was in the study intervention/control for 3 months
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Continuous Glucose Monitoring (CGM) | The RT CGM group will receive a Dexcom G6 transmitter and sensors, as well as a structured education refresher focusing on hypoglycaemia avoidance, recognition, and management. Dexcom G6 CGM: Commercially available Dexcom G6 Continuous Glucose Monitoring | 0 | 16 | 0 | 16 | 0 | 16 |
| EG001 | Self Monitoring Blood Glucose (SMBG) | The SMBG group will additionally undergo blinded CGM at weeks 1 and 2, weeks 4 to 6 and weeks 9 to 12 using the Dexcom G6 system. Participants in this group will be shown how to insert the Dexcom G6 at the first clinic visit and sensors provided so they can do this at home. | 0 | 14 | 4 | 14 | 0 | 14 |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Unrelated to intervention | Endocrine disorders | Non-systematic Assessment |
|
Not provided
The study was terminated early after the interim analysis. It was deemed unethical to offer SMBG to this high risk population.
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Professor Nick Oliver | Imperial College London | +44 (0)20 7594 1796 | nick.oliver@imperial.ac.uk |
| Sep 14, 2023 |
| Prot_SAP_000.pdf |
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| D007003 | Hypoglycemia |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |
Not provided
Not provided
| Male |
|
| Not Hispanic or Latino |
|
| Unknown or Not Reported |
|