Variations of cardiac output are frequent in pregnant women during obstetrical procedures, and may participate to poor foetal outcomes through decrease of uteroplacental bloodflow. Thus, monitoring maternal cardiac output appears of major interest, as it would open the way to early initiation of hemodynamic supportive management.
The ccNexfin© is a non-invasive hemodynamic monitoring device, whose relevance for continuous monitoring of cardiac output has been reported in a non-pregnant population.
The hypothesis is that ccNexfin© gives acceptable measurement of maternal cardiac output in pregnant women.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ccNexfin © | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| cardiac output by ccNexfin © | Device | Measurement of cardiac output by ccNexfin © comparatively to transthoracic echocardiography Subjects participating to the study will be simultaneously measured for cardiac output by ccNexfin © and transthoracic echocardiography. Echocardiographic measurements of cardiac output will be blinded to values measured by ccNexfin ©. For each participant, a first measurement of cardiac output will be performed in the supine position and then after 1 minute of strict left lateral position. |
| Measure | Description | Time Frame |
|---|---|---|
| Intra-class correlation coefficient between values of supine position cardiac output evaluated simultaneously by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute) | 1 minute after positioning in supine position |
| Measure | Description | Time Frame |
|---|---|---|
| Cohen's Kappa coefficient between changes in maternal ejection volume observed from supine position to left lateral position, evaluated by transthoracic echocardiography (in %) and ccNexfin © (in %) respectively, at the 10% threshold of variation | Maternal ejection volume in supine position: 1 minute after positioning in supine position Maternal ejection volume in left lateral position: 1 minute after positioning in left lateral position |
Not provided
Inclusion Criteria
Exclusion Criteria:
Pregnant
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Alexandre GAUDET, MD | University Hospital, Lille | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hôpital coeur poumon, CHU | Lille | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35927539 | Result | Bonnin P, Constans B, Duhamel A, Kyheng M, Ducloy-Bouthors AS, Estevez MG, Tavernier B, Gaudet A. Accuracy and trending ability of finger plethysmographic cardiac output monitoring in late pregnancy. Can J Anaesth. 2022 Nov;69(11):1340-1348. doi: 10.1007/s12630-022-02297-y. Epub 2022 Aug 4. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Cohen's Kappa coefficient between changes in maternal cardiac output observed from supine position to left lateral position, assessed by transthoracic echocardiography (in %) and ccNexfin © (in %) respectively, at the 15% threshold of variation | Maternal cardiac output in supine position: 1 minute after positioning in supine position Maternal cardiac output in left lateral position: 1 minute after positioning in left lateral position |
| Intra-class correlation coefficient between left lateral position cardiac output values assessed simultaneously by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute) | 1 minute after positioning in left lateral position |
| Pearson correlation coefficient between values of supine position maternal cardiac output evaluated by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute), respectively | 1 minute after positioning in supine position |
| Pearson correlation coefficient between values of left lateral position maternal cardiac output evaluated by transthoracic echocardiography (measured in liters / minute) and ccNexfin © (measured in liters / minute), respectively | 1 minute after positioning in left lateral position |