This is a randomized controlled trial to compare viscoelastometric (VE) guided transfusion to standard practice transfusion in severe thermal injury burn excision on the utilization of blood products, effects on coagulation and inflammatory mediators, and how these strategies affect post resuscitation infections.
This is an open labeled study as the viscoelastometric (VE) guided transfusion will be based on the visible VE results. Subjects will be randomized to receive either the standard practice transfusion or VE guided transfusion. Blood samples, standard demographic information, and routine laboratory data will be collected on all subjects in the Burn ICU (BICU) enrolled in the study. VE analysis will be performed on ALL subjects immediately prior to the burn excision, and approximately every 40 minutes while the patient is in the operating room (OR) as well as on arrival to the BICU and every 8 hours depending on their need for ongoing transfusion for a maximum of 24 hours. As our intervention, only the VE based transfusion group will have access to the VE analysis at time of transfusion. The VE results will be used at the discretion of the treating physician based on the VE guided transfusion algorithm. Outcomes include the number and timing of blood products transfused from the time of randomization to 24 hours post randomization and the presence of any 30 day post-transfusion infections.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Viscoelastic (VE) guided transfusion | Experimental | The intervention made in the VE guided transfusion group is that the VE results will be available to the treating physicians to guide transfusions based on VE results during their burn excision. |
|
| Standard practice transfusion | No Intervention | The standard practice transfusion group will receive the current standard transfusion practice during their burn excision, which is based solely on physician preference using standard lab values. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Viscoelastic (VE) Guided Transfusion | Procedure | A viscoelastic analyzer (ROTEM) will be used to guide the transfusion algorithm during the burn wound excision of subjects enrolled into this arm |
| Measure | Description | Time Frame |
|---|---|---|
| Number of blood products transfused | Compare the number of blood products transfused in VE guided transfusion versus standard practice transfusion in burned patients (TBSA >20%) undergoing burn wound excision will be analyzed. | 24 hours post randomization |
| Measure | Description | Time Frame |
|---|---|---|
| Coagulation factors | Compare the effects of VE guided transfusion to standard practice transfusion on the coagulation factor in patients undergoing burn wound excision. Changes in individual coagulation factors will be measured. Will measure other related mediators including coagulation Factors V, VIII, and plasminogen activator inhibitor 1 (PAI-1) which have also been implicated in ATC. | excision to 24 hours post excision |
| Measure | Description | Time Frame |
|---|---|---|
| Post transfusion infections | Compare the post transfusion infections to the number of blood products transfused for VE guided transfusion and standard practice transfusion in patients undergoing burn wound excision. | 30 days |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael W Cripps, MD | University of Texas Southwestern Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Parkland Memorial Hospital | Dallas | Texas | 75206 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 22719014 | Background | Schaden E, Kimberger O, Kraincuk P, Baron DM, Metnitz PG, Kozek-Langenecker S. Perioperative treatment algorithm for bleeding burn patients reduces allogeneic blood product requirements. Br J Anaesth. 2012 Sep;109(3):376-81. doi: 10.1093/bja/aes186. Epub 2012 Jun 19. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002056 | Burns |
| ID | Term |
|---|---|
| D014947 | Wounds and Injuries |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Inflammatory Mediators - plasminogen activator inhibitor 1 | Compare the effects of VE guided transfusion to standard practice transfusion on the inflammatory mediators in patients undergoing burn wound excision. Changes in inflammatory mediators will be measured. Further, analysis into interactions between these factors will be studied. | excision to 24 hours post excision |