Peripherally inserted central catheters (PICCs) are central catheters that are placed via peripheral vein under ultrasound guidance and may be used for patients with difficult venous access for long-term central or peripheral infusion therapies as well as central venous pressure monitoring in a critical care setting. Although PICCs provide a great option for some patients, these catheters have known complications including catheter-related bloodstream infection, catheter-related venous thrombosis or clotting, malfunction, and high cost. Midline catheters represent a potentially attractive alternative to PICCs for peripheral infusions. As midlines have increased in popularity and new midlines have been introduced into the market, it is necessary to better understand complication profiles of various midline catheters, as it is likely that all catheters are not created equal. Specifically, the incidence of symptomatic catheter-related thrombosis is of interest. Some midline catheters are coated to provide protection against catheter-related venous thrombosis and/or catheter-related bloodstream infection. The theoretical benefit(s) of these catheters need further validation in human subjects.
Study Design
The investigators propose a prospective single-site, parallel, two-arm, randomized investigation to assess catheter-related symptomatic upper extremity venous thrombosis (CR-UEVT), catheter-related bloodstream infection, and functionality of two single lumen midline catheters: AngioDynamics BioFlo 4 F and Teleflex Arrowg+ard Blue Advance 4.5 F.
Research staff of Beaumont Health Institute will allocate two midline catheters to eligible participants according to a pre-generated randomized list at a 1:1 ratio in block randomization to AngioDynamics BioFlo or Tele-flex Arrowg+ard Blue Advanced midline catheters. Participant enrollment will take place from November 2018 until recruitment of 250 participants, 125 in each group, is complete. Demographic and health-related information will be obtained from electronic medical records during enrolled period at William Beaumont Hospital.
Practitioner Participation/Training
Advanced Practice Providers within the bedside PICC/Midline service at the Royal Oak campus are eligible to place catheters for this study. All investigators are credentialed in placing PICCs and midlines by institutional policy and have greater than one year of experience in these procedures.
Initial Assessment
Post-cannulation and post securement, functionality is confirmed with blood sampling (10 cc) and flush without resistance.
The research team also will document practitioner details, the vascular access device (VAD) used, the time of VAD placement, number of attempts, need for a rescue inserter, the vein that was cannulated, depth and diameter of the vein, and the indication for VAD placement. An attempt is defined as each time the needle punctures the skin. Data will be collected from the electronic medical record and includes: age, gender, body mass index (BMI), vital signs, relevant past medical history. Indication for catheter placement will also be recorded.
Follow-up Assessment
Investigators will perform a follow-up assessment on all catheters within 24 hours of insertion and then daily for the life of the VAD. At each follow-up interval, the researcher will document the time of evaluation and assessment of functionality as well as review the patient chart for signs and symptoms of catheter-related bloodstream infection. If the catheter was identified to have failed during follow-up assessment the date and time of failure and the reason for failure will be documented. For all failed catheters, re-insertion attempt data will be tracked through the medical record.
Superficial venous thrombosis (SVT) and deep venous thrombosis (DVT) rates will be calculated based on upper extremity proven diagnosis of SVT and/or DVT in symptomatic cases. Radiology interpretations will be reviewed for findings consistent with CR-UEVT.
Infection rate will be tracked using confirmed catheter-related blood stream infection data from the surveillance team within the epidemiology department. The team utilizes the CDC definition of laboratory-confirmed blood-stream infection (LCBSI).
The medication administration record will be queried for all medications given through each catheter.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Angiodynamics BioFlo Midline Catheter | Active Comparator | Placement of clinically indicated Angiodynamics BioFlo midline catheter. |
|
| Teleflex Arrowg+ard Blue Advanced Midline Catheter | Active Comparator | Placement of clinically indicated Teleflex Arrowg+ard Blue Advanced Midline Catheter |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Angiodynamics BioFlo Midline Catheter | Device | Placement of Angiodynamics BioFlo Midline Catheter. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Upper Extremity CR-UEVT | Number of participants with proven sonographic diagnosis of DVT and/or SVT | 30 days post line insertion |
| Measure | Description | Time Frame |
|---|---|---|
| Line Related Infection | Number of participants with catheter related laboratory confirmed bloodstream infection per Centers for Disease Control (CDC) guidelines | 30 days post line insertion |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Amit Bahl, MD | Corewell Health East | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Beaumont Hospital - Royal Oak | Royal Oak | Michigan | 48073 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 37611283 | Derived | Bahl A, Johnson S, Mielke N, Chen NW. Risk Factors for Coated Midline Catheter-Related Thrombosis: A Secondary Analysis of Existing Trial Data. J Infus Nurs. 2023 Sep-Oct 01;46(5):259-265. doi: 10.1097/NAN.0000000000000518. | |
| 34613402 | Derived | Bahl A, Diloreto E, Jankowski D, Hijazi M, Chen NW. Comparison of 2 Midline Catheter Devices With Differing Antithrombogenic Mechanisms for Catheter-Related Thrombosis: A Randomized Clinical Trial. JAMA Netw Open. 2021 Oct 1;4(10):e2127836. doi: 10.1001/jamanetworkopen.2021.27836. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Angiodynamics BioFlo Midline Catheter | Placement of clinically indicated Angiodynamics BioFlo midline catheter. Angiodynamics BioFlo Midline Catheter: Placement of Angiodynamics BioFlo Midline Catheter. |
| FG001 | Teleflex Arrowg+Ard Blue Advanced Midline Catheter | Placement of clinically indicated Teleflex Arrowg+ard Blue Advanced Midline Catheter Teleflex Arrowg+ard Blue Advanced Midline Catheter: Placement of Teleflex Arrowg+ard Blue Advanced Midline Catheter. |
| Title | Milestones | Reasons Not Completed | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Angiodynamics BioFlo Midline Catheter | Placement of clinically indicated Angiodynamics BioFlo midline catheter. Angiodynamics BioFlo Midline Catheter: Placement of Angiodynamics BioFlo Midline Catheter. |
| BG001 | Teleflex Arrowg+Ard Blue Advanced Midline Catheter |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Upper Extremity CR-UEVT | Number of participants with proven sonographic diagnosis of DVT and/or SVT | Posted | Count of Participants | Participants | 30 days post line insertion |
|
30 days post line insertion
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Angiodynamics BioFlo Midline Catheter | Placement of clinically indicated Angiodynamics BioFlo midline catheter. Angiodynamics BioFlo Midline Catheter: Placement of Angiodynamics BioFlo Midline Catheter. |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Pulmonary Embolism | Blood and lymphatic system disorders | Systematic Assessment |
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Catheter Failure | Blood and lymphatic system disorders | Systematic Assessment | Catheter failure prior to completion of therapy |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Amit Bahl, MD | Beaumont Hospitals | (248) 898-9111 | ahmit.bahl@beaumont.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Apr 30, 2019 | Dec 2, 2021 | Prot_SAP_000.pdf |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D013927 | Thrombosis |
| D020246 | Venous Thrombosis |
| ID | Term |
|---|---|
| D016769 | Embolism and Thrombosis |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Prospective single-site, parallel, two-arm, randomized investigation
Not provided
Not provided
Not provided
Not provided
| Teleflex Arrowg+ard Blue Advanced Midline Catheter | Device | Placement of Teleflex Arrowg+ard Blue Advanced Midline Catheter. |
|
| venous anatomy screen failures |
|
Placement of clinically indicated Teleflex Arrowg+ard Blue Advanced Midline Catheter Teleflex Arrowg+ard Blue Advanced Midline Catheter: Placement of Teleflex Arrowg+ard Blue Advanced Midline Catheter. |
| BG002 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
|
|
| Secondary | Line Related Infection | Number of participants with catheter related laboratory confirmed bloodstream infection per Centers for Disease Control (CDC) guidelines | Posted | Count of Participants | Participants | 30 days post line insertion |
|
|
|
| 0 |
| 94 |
| 1 |
| 94 |
| 22 |
| 94 |
| EG001 | Teleflex Arrowg+Ard Blue Advanced Midline Catheter | Placement of clinically indicated Teleflex Arrowg+ard Blue Advanced Midline Catheter Teleflex Arrowg+ard Blue Advanced Midline Catheter: Placement of Teleflex Arrowg+ard Blue Advanced Midline Catheter. | 0 | 97 | 0 | 97 | 20 | 97 |
|