Breast asymmetry is a rare in plastic surgery. In majority of cases, it is idiopathic.
In cases that are poorly tolerated physically (vertebral imbalance, posture disorders) or psychologically, the decision to perform breast symmetrization surgery can be made. It is recommended to do this surgery after a slimming treatment if the woman is overweight or after pregnancy that causes a change in the structure and volume of the chest. In fact, the weight variations deteriorate the long-term result.
However, this surgical management remains difficult. In fact, the volume to be removed (unilateral breast reduction) to be symmetrized is a function of the volume of the contralateral breast and the preoperative drawings are made while standing. Currently, the evaluation of the volume to be removed remains subjective and is based on the experience of the surgeon. In addition, intraoperatively, this evaluation is also subjective because the patient is lying down which changes the position of the anatomical landmarks: the optimization of the symmetrization is only possible by the eye and the touch.
No measuring device is currently used to assess the difference in volume between the 2 breasts and guide the surgeon in the volume (or weight) to remove. It is therefore sometimes necessary to perform a second intervention in case of residual postoperative asymmetry.
Primary objective :
To study the association between the weight of tissues removed during the intervention and the variation of the breast volume (pre / postoperative) measured by the Créaform® GOPRO 3D digital camera adjusted on the density of the gland measured by electronic palpation (MyotonPRO).
Second objective : To study the association between the weight of tissues removed during the procedure and the variation of the breast volume (pre / postoperative) measured by the Créaform® GOPRO 3D digital camera adjusted on the density of the gland estimated by manual palpation (Likert scale from 1 to 5).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| arm 1 : Creaform3D + MyotonPRO | Experimental | A clinical questionnaire is completed by the investigator (chest circumference, thorax turn, breast "measurements"). The breast density is assessed by the surgeon and scored from 1 to 5 (Likert scale) and then by the MyotonPRO The volumetric measurement of the breast is performed using the 3D digital camera. The patient is bent forward with hands resting on a chair during 30 seconds to 1 minute. The 3D digital camera rotates around the breast to capture the volume of the breast. Intraoperatively, the weight of tissues removed is weighed (in grams), recorded in the observation notebook. In post-operative (4 months), the possible long-term complications related to the intervention (mainly the dissatisfaction of the patient as for the aesthetic result) are collected then a new acquisition of the mammary volume is carried out with the digital camera 3D. Once this measurement is completed, participation in the study is complete |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| arm 1 : Creaform3D + MyotonPRO | Other | After inclusion,are carried out:
The volumetric measurement of the breast is performed using the 3D digital camera. The patient is bent forward with hands resting on a chair to be as still as possible over a period of 30 seconds to 1 minute. The 3D digital camera rotates around the breast to capture the volume of the breast. In peroperative, the weight of tissues removed is weighed (in grams). The removed weight is recorded in the observation notebook. In postoperative (4 months), the possible long-term complications related to the intervention (mainly the dissatisfaction of the patient as for the aesthetic result) are collected then a new acquisition of the mammary volume is carried out with the digital camera 3D. Once this measurement is completed, participation in the study is complete. |
| Measure | Description | Time Frame |
|---|---|---|
| association between weight and volume adjusted to the density of the gland measured by electronic palpation | To study the association between the weight of tissues removed during the intervention and the variation of the breast volume (pre / postoperative) measured by the Créaform® GOPRO 3D digital camera adjusted on the density of the gland measured by electronic palpation (MyotonPRO). Primary judgment criterion: Coefficient associated with volume variation in the linear regression model (model 1) explaining weight by volume variation and density measured by electronic palpation. | one year |
| Measure | Description | Time Frame |
|---|---|---|
| association between weight and volume adjusted to the density of the gland estimated by manual palpation | To study the association between the weight of tissues removed during the procedure and the variation of the breast volume (pre / postoperative) measured by the Créaform® GOPRO 3D digital camera adjusted on the density of the gland estimated by manual palpation (Likert scale from 1 to 5). Secondary judgment criterion 1: Coefficient associated with volume variation in the linear regression model (Model 2) explaining weight by volume variation and estimated density by manual palpation. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU Angers | Angers | Maine Et Loire | 49933 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| C565299 | Anisomastia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| one year |
| comparison of models 1 and 2 | Comparison of models 1 and 2 (estimated density by manual palpation or measured by electronic method), to see if one model is better than the other. Secondary judgment criterion 2: Akaike Criterion | one year |