A Multi-center, Randomized Controlled Trial to evaluate the safety and efficacy of Fitaya Vena Cava Filter manufactured by Lifetech Scientific (Shenzhen) Co., LTD. for deep vein thrombosis.
The trial was mainly for patients with high-risk deep vein thrombosis, and all subjects who passed the screening and signed the informed consent will be enrolled and be randomly divided into the experimental group and the control group according to the proportion of 1:1. For patients who will be allocated to the experimental group will be implanted with Fitaya Vena Cava Filters System, and for patients who will be allocated to the control group will be implanted with Aegisy Vena Cava Filters. Between 0 and 60 days, after the filter was implanted, the investigator will decide whether to withdraw the vena cava filter based on the subject's condition. If successfully withdraw the vena cava filter, the subject will be followed up for 1 month, if the withdraw is unsuccessful, the subject will be followed up for 180 days. This clinical trial is conducted in qualified clinical trial institutions with a planned duration of 16-24 months. Upon completion of the clinical trial report, it will be submitted together with other materials for the application for listing registration in the China Food and Drug Administration (CFDA).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Experimental arm | Experimental | Patients will be treated with Fitaya Vena Cava Filter System. |
|
| Control arm | Active Comparator | Patients will be treated with Aegisy Vena Cava Filter. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Fitaya Vena Cava Filter System | Device | After the implantation of Fitaya Vena Cava Filter, the filter can be withdrawn from the patient within the window period (60 days) by using the withdraw system in junction of the sheath. |
| Measure | Description | Time Frame |
|---|---|---|
| The clinical success rate of the filter implantation | The clinically successful implantation of vena cava filter should meet the following three requirements simultaneously: 1. The filter was successfully implanted and the shape and positioning were satisfactory. 2. No symptomatic pulmonary embolism occurred in patients with permanent filter implantation within 6 months after implantation and was confirmed by Computed Tomography Pulmonary Angiography (CTPA). No symptomatic pulmonary embolism occurred in patients who had a removal of the filter during its indwelling and was confirmed by CTPA. 3. No rupture, no displacement, no venous penetration, no vena occlusion, no filter implantation or operation-related deaths occurred in the blood vessels. | 6 months after implantation |
Not provided
Not provided
Inclusion Criteria:
Older or equal to 18 years of age, regardless of sex.
Patients are able to understand the purpose of the trial, voluntarily participated in and signed informed consent, and are willing to complete the follow-up as required by the program.
Patients diagnosed with inferior deep vein thrombosis (inferior vena cava, Iliac, femoral or popliteal DVT) or pulmonary embolism (PE), and concomitant with one or more of the following situation:
The investigator determined that the patient had an appropriate femoral or jugular access for implantation of the filter.
The diameter of inferior vena cava intended to implant the filter is between 18mm and 29mm.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Ying Xia | Contact | +86 13760184511 | xiaying@lifetechmed.com |
| Name | Affiliation | Role |
|---|---|---|
| Xiaoming Zhang, Professor | Peking University People's Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Beijing Jishuitan Hospital | Recruiting | Beijing | Beijing Municipality | China |
Not provided
| ID | Term |
|---|---|
| D054556 | Venous Thromboembolism |
| ID | Term |
|---|---|
| D013923 | Thromboembolism |
| D016769 | Embolism and Thrombosis |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Aegisy Vena Cava Filter | Device | After the implantation of Aegisy Vena Cava Filter, the filter can be withdrawn from the patient within the window period (60 days) by using the withdraw system in junction of the sheath. |
|
| Peking University People's Hospital | Recruiting | Beijing | Beijing Municipality | China |
|
| Liuzhou Worker's Hospital | Recruiting | Liuzhou | Guangxi | China |
|
| Affiliated Hospital of Zunyi Medical College | Recruiting | Zunyi | Guizhou | China |
|
| Union Hospital Tongji College Huazhong University of Science and Technology | Recruiting | Wuhan | Hubei | China |
|
| The Affiliated Hospital of Shandong University of TCM | Recruiting | Jinan | Shandong | China |
|
| Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine | Recruiting | Shanghai | Shanghai Municipality | China |
|
| Second Hospital of Shanxi Medical University | Recruiting | Taiyuan | Shanxi | China |
|
| Tianjin People's Hospital | Recruiting | Tianjin | Tianjin Municipality | China |
|
| Tianjing Medical University General Hospital | Recruiting | Tianjin | Tianjin Municipality | China |
|
| Frist Affiliated Hospital of Kunming Medical University | Recruiting | Kunming | Yunnan | China |
|
| Ningbo No.2 Hospital | Recruiting | Ningbo | Zhejiang | China |
|
| Taizhou Hospital of Zhejiang Province | Recruiting | Taizhou | Zhejiang | China |
|