KoMAC videolaryngoscope is a portable intubating device with an angulated single-use blade of adjustable size and a liquid crystal display monitor mounted on top of the handle, which is similar in shape to the McGrath videolaryngoscope. The purpose of this study was to evaluate the efficacy of the KoMAC videolaryngoscope for double-lumen intubation regarding intubation time, laryngeal view and ease of intubation, compared to Macintosh laryngoscope.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| KoMAC group | Experimental | Orotracheal intubation with KoMAC videolaryngoscope |
|
| Macintosh group | Active Comparator | Orotracheal intubation with Macintosh laryngoscope |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| KoMAC videolaryngoscope | Device | Double lumen endotracheal intubation was performed with the KoMAC videolaryngoscope |
|
| Measure | Description | Time Frame |
|---|---|---|
| Intubation time | Time interval between laryngoscope passing the teeth to the confirming of end tidal CO2 | from 2 min after rocuronium injection to completion of intubation (time interval is about 120 seconds) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jong Yeop Kim | Ajou University School of Medicine | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ajou University Hospital | Suwon | Gyeonggi-do | 16499 | South Korea |
Not provided
Not provided
Not provided
Not provided
Not provided
| Macintosh Laryngoscope | Device | Double lumen endotracheal intubation was performed with the Macintosh Laryngoscope |
|