The primary objective of this study is to evaluate the distance, intermediate and near visual performance of Clerio designed single vision and Clerio designed LIRIC modified bifocal lenses (+2.00D add) compared to commercially available single vision and multifocal lenses.
Clerio Vision Inc. has licensed a new femtosecond based laser procedure discovered by researchers at the University of Rochester known as Laser Induced Refractive Index Customization (LIRIC), which allows the alteration of the optical design of a finished soft hydrogel contact lens. Clerio Vision Inc. scientists have developed a diffractive multifocal optical design using the LIRIC procedure which shows an increase of the depth of focus of the contact lens when measured on an optical bench. It is hypothesized that a presbyopic patient wearing a soft contact lens of this design will experience an improvement in intermediate and near vision over that provided by their distance corrected single vision contact lenses, without significantly impacting their distance vision. The purpose of this feasibility study is the on-eye evaluation of the performance of the Clerio Vision designed and LIRIC modified soft contact lenses. Results from this study will guide future development of these potential products.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Test Device | Experimental | Within this arm the Clerio Vision LIRIC-modified Bifocal Contact Lens is administered. |
|
| Control Devices | Active Comparator | Within this arm the Johnson & Johnson 1-Day Acuvue Moist Multifocal Contact Lens, Johnson & Johnson 1-Day Acuvue Moist Contact Lens, and Clerio Vision Single Vision Contact Lens are administered. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Clerio Vision LIRIC-modified Bifocal Contact Lens | Device | Within this arm the investigational acofilcon B material bifocal contact lens, which has been modified with the laser and is the focus of the study, is tested. This lens is one of four (4) administered to each participant, tested on either visit 2 or 3 according to the randomization schedule, for a period of approximately 20 minutes. |
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of Through-Focus High Contrast logMAR Visual Acuity for the Test Bifocal Contact Lens Versus that of the Control Bifocal Contact Lens, the Control Single Vision Contact Lens 1, and the Control Single Vision Contact Lens 2 | Visual acuity is measured under high contrast conditions (85% contrast relative to the chart background) at object testing distances of 5.3m, 2m, 1m, 67cm, 50cm and 40cm ("through-focus"), recorded in units of logMAR. | starting from visit 2 (after enrollment) and finishing with visit 3, the exit visit (up to 60 days after visit 2) |
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of Through-Focus Low Contrast logMAR Visual Acuity for the Test Bifocal Contact Lens Versus that of the Control Bifocal Contact Lens, the Control Single Vision Contact Lens 1, and the Control Single Vision Contact Lens 2 | Visual acuity is measured under low contrast conditions (10% contrast relative to the chart background) at object testing distances of 5.3m, 2m, 1m, 67cm, 50cm and 40cm ("through-focus"), recorded in units of logMAR. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michele Lagana, OD | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Clerio Vision Research Clinic | Rochester | New York | 14607 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19529613 | Background | Ding L, Blackwell R, Kunzler JF, Knox WH. Large refractive index change in silicone-based and non-silicone-based hydrogel polymers induced by femtosecond laser micro-machining. Opt Express. 2006 Nov 27;14(24):11901-9. doi: 10.1364/oe.14.011901. | |
| 18641284 | Background | Ding L, Knox WH, Buhren J, Nagy LJ, Huxlin KR. Intratissue refractive index shaping (IRIS) of the cornea and lens using a low-pulse-energy femtosecond laser oscillator. Invest Ophthalmol Vis Sci. 2008 Dec;49(12):5332-9. doi: 10.1167/iovs.08-1921. Epub 2008 Jul 18. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This single center study is a device feasibility, two-arm, double-masked (participants and outcomes assessor), repeated measures, cross-sectional design. Each participant is tested with the four (4) study devices (i.e., contact lenses), one (1) test lens and three (3) control lenses, in randomized order. Participants are masked to each lens they wear.
Not provided
Not provided
The Principal Investigator and Clinical Research Technicians, because they handle the contact lenses both in and out of their packaging, are not masked.
|
|
| Johnson & Johnson 1-Day Acuvue Moist Multifocal Contact Lens | Device | Within this arm the control etafilcon A material bifocal contact lens, which is commercially available, is tested. This lens is one of four (4) administered to each participant, tested on either visit 2 or 3 according to the randomization schedule, for a period of approximately 20 minutes. |
|
|
| Johnson & Johnson 1-Day Acuvue Moist Contact Lens | Device | Within this arm the control etafilcon A material single vision contact lens, which is commercially available, is tested. This lens is one of four (4) administered to each participant, tested on either visit 2 or 3 according to the randomization schedule, for a period of approximately 20 minutes. |
|
|
| Clerio Vision Single Vision Contact Lens | Device | Within this arm the control acofilcon B material single vision contact lens, the material of which is commercially available from Contamac Ltd, is tested. This lens is one of four (4) administered to each participant, tested on either visit 2 or 3 according to the randomization schedule, for a period of approximately 20 minutes. |
|
|
| starting from visit 2 (after enrollment) and finishing with visit 3, the exit visit (up to 60 days after visit 2) |
| Comparison of Visual Quality for the Test Bifocal Contact Lens Versus that of the Control Bifocal Contact Lens, the Control Single Vision Contact Lens 1, and the Control Single Vision Contact Lens 2 | Visual quality is a subjective rating that a participant chooses using an analog rating chart ranging from 0 to 100. Participants are asked to look at the letters that they can read, not the ones that they can't, and rate how sharp those letters are, with 0 denoting "unacceptable" and 100 denoting "excellent." They are asked to reduce their score if any halos, glare, or double vision are present. | starting from visit 2 (after enrollment) and finishing with visit 3, the exit visit (up to 60 days after visit 2) |
| Comparison of Fitting Performance for the Test Bifocal Contact Lens Versus that of the Control Bifocal Contact Lens, the Control Single Vision Contact Lens 1, and the Control Single Vision Contact Lens 2 | Fitting performance is measured by visual observation of the contact lens on a participant's eye using a slit lamp biomicroscope and ocular measurement reticle. The position of the lens edge relative to the corneal boundaries both immediately before and immediately after a blink is measured. | starting from visit 2 (after enrollment) and finishing with visit 3, the exit visit (up to 60 days after visit 2) |
| 21931133 | Background | Xu L, Knox WH, DeMagistris M, Wang N, Huxlin KR. Noninvasive intratissue refractive index shaping (IRIS) of the cornea with blue femtosecond laser light. Invest Ophthalmol Vis Sci. 2011 Oct 17;52(11):8148-55. doi: 10.1167/iovs.11-7323. |
| 24985471 | Background | Savage DE, Brooks DR, DeMagistris M, Xu L, MacRae S, Ellis JD, Knox WH, Huxlin KR. First demonstration of ocular refractive change using blue-IRIS in live cats. Invest Ophthalmol Vis Sci. 2014 Jul 1;55(7):4603-12. doi: 10.1167/iovs.14-14373. |
| 28866013 | Background | Wozniak KT, Elkins N, Brooks DR, Savage DE, MacRae S, Ellis JD, Knox WH, Huxlin KR. Contrasting cellular damage after Blue-IRIS and Femto-LASIK in cat cornea. Exp Eye Res. 2017 Dec;165:20-28. doi: 10.1016/j.exer.2017.08.018. Epub 2017 Aug 31. |
| ID | Term |
|---|---|
| D011305 | Presbyopia |
| D012030 | Refractive Errors |
| D009216 | Myopia |
| D006956 | Hyperopia |
| D001251 | Astigmatism |
| ID | Term |
|---|---|
| D005128 | Eye Diseases |
Not provided