To determine the most frequent complication associated with cryoballoon PVI. The main hypothesis is to explore the incidence of phrenic nerve palsy.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of phrenic nerve palsy | The overall incidence of phrenic nerve palsy during second and third Generation Cryoballoon based PVI will be evaluated. | 06/2012 until 04/2018 |
| Measure | Description | Time Frame |
|---|---|---|
| Predictors of phrenic nerve palsy | Predictors for transient and permanent phrenic nerve palsy will be evaluated. For this purpose baseline characteristics (e.g. age, sex, BMI, CHADS-VASc-Score) as well as periprocedural data (e.g. minimal cryoballoon temp., cryoballoon temp. after 30 seconds, time to isolation, PV diameter, use of doublestopp technique and draw back manouever) will be assesseda and predictors will be calculated using adequat statistical techniques. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
- Non
Not provided
Not provided
Not provided
All patients who underwent a PVI by the second generation Cryoballoon.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Heart Center Luebeck, Electrophysiology | Lübeck | Germany |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 36414239 | Derived | Heeger CH, Popescu SS, Sohns C, Pott A, Metzner A, Inaba O, Straube F, Kuniss M, Aryana A, Miyazaki S, Cay S, Ehrlich JR, El-Battrawy I, Martinek M, Saguner AM, Tscholl V, Yalin K, Lyan E, Su W, Papiashvili G, Botros MSN, Gasperetti A, Proietti R, Wissner E, Scherr D, Kamioka M, Makimoto H, Urushida T, Aksu T, Chun JKR, Aytemir K, Jedrzejczyk-Patej E, Kuck KH, Dahme T, Steven D, Sommer P, Tilz RR. Impact of cryoballoon application abortion due to phrenic nerve injury on reconnection rates: a YETI subgroup analysis. Europace. 2023 Feb 16;25(2):374-381. doi: 10.1093/europace/euac212. | |
| 34962134 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
Not provided
Not provided
Not provided
Not provided
Not provided
| 06/2012 until 04/2018 |
| Clinical course of phrenic nerve palsy | The clincial course of phrenic nerve palsy after second and third Generation Cryoballoon based PVI will be evaluated by follow-up appointments according to each centers standard of care. For this purpose follow-up data will be evaluated and the clinical course will be assessed. | 06/2012 until 04/2018 |
| Derived |
| Heeger CH, Sohns C, Pott A, Metzner A, Inaba O, Straube F, Kuniss M, Aryana A, Miyazaki S, Cay S, Ehrlich JR, El-Battrawy I, Martinek M, Saguner AM, Tscholl V, Yalin K, Lyan E, Su W, Papiashvili G, Botros MSN, Gasperetti A, Proietti R, Wissner E, Scherr D, Kamioka M, Makimoto H, Urushida T, Aksu T, Chun JKR, Aytemir K, Jedrzejczyk-Patej E, Kuck KH, Dahme T, Steven D, Sommer P, Richard Tilz R. Phrenic Nerve Injury During Cryoballoon-Based Pulmonary Vein Isolation: Results of the Worldwide YETI Registry. Circ Arrhythm Electrophysiol. 2022 Jan;15(1):e010516. doi: 10.1161/CIRCEP.121.010516. Epub 2021 Dec 28. |
| D013568 |
| Pathological Conditions, Signs and Symptoms |