The Implantable Myoelectric Sensors (IMES) system is an investigational device intended to improve signal quality and consistency of myoelectric signals for prosthetic control in individuals suffering from an above elbow (transhumeral) amputation. The sensors pick up myoelectric signals intramuscularly and therefore signal quality is not affected from electrode replacement, perspiration, or artefacts.
Implantable Myoelectric Sensors (IMES), the surgical tools implantation, and the external equipment used to control an electromechanical prosthetic device, together comprise the IMES System (investigational product, medical device).
Each IMES acts as an independent differential amplifier consisting of custom electronics housed within a biocompatible, hermetically sealed ceramic cylinder with metal end caps. The end caps serve as electrodes for picking up EMG activity during muscle contraction. Reverse telemetry (via a coil around the arm) is used to transfer data from the implanted sensor, and forward telemetry is used to transmit power and configuration settings to the sensors. The coil and associated electronics are housed within the frame of a prosthesis. A control system that sends data associated with muscle contraction to the motors of the prosthetic joints is housed in a belt-worn, battery-powered device. A cable attaches the control unit to the prosthetic frame.
An IMES is implanted into each targeted muscle that will be used to control a function of the prosthetic arm. Two IMES devices are needed for each DOF. For example, one device would control fingers opening and another device would control fingers closing.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Implantation | Other | Surgical Implantation of IMES sensors |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Implantation of IMES sensors | Device | Surgical implantation of IMES sensors during routine surgery to improve prosthetic control |
|
| Measure | Description | Time Frame |
|---|---|---|
| Change in hand function over time | Southampton Hand Assessment Procedure | at 3, 6, 9 and 12 months after final prosthetic fitting |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Christian Hofer, PhD | Otto Bock | Study Chair |
Not provided
The study including all results is already submitted to be published
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided