The aim of this study is to compare the effects of different intra-arterial catheter size on the frequency of optimal dynamic response in radial arterial waveform.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 20 gauge | Placebo Comparator |
| |
| 22 gauge | Active Comparator |
| |
| 24 gauge | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| different intra-arterial catheter size | Device | in placebo group, patients were cannulated with 20 gauge intra-arterial catheter. In experiment groups, patients were cannulated with 22 gauge or 24 gauge intra-arterial catheter. |
| Measure | Description | Time Frame |
|---|---|---|
| The frequency of adequately damped arterial waveform | The accuracy of arterial blood pressure waveform is depedent on damping coefficient (DC) and natural frequency (NF). The extent to which a monitoring system is damped is expressed by the DC, while the frequency of oscillation that a monitoring system resonates at is known as the NF. The NF and DC are required to be within certain rages for accurate blood pressure monitoring, and they can be affected by different arterial catheter size. Adequately damped arterial waveform can be defined as NF and DC being within certain ranges. For example, waveforms with DC of 0.5 at a NF of 15Hz can be regarded as adequately damped arterial waveform. However, if waveforms have DC of 0.1 at a NF of 15Hz, these can be regarded as not having optimal dynamic response. (There is a reference figure explaining these factors in detail in a previous article. Gardner RM: Direct blood pressure measurement--dynamic response requirements. Anesthesiology 1981; 54:227-3) | 1 minute after cannulation |
| Measure | Description | Time Frame |
|---|---|---|
| The difference of mean blood pressure between invasive blood pressure and non-invasive blood pressure | At 1 minute after cannulating radial artery, we will obtain information about the mean blood pressure measured in both invasive blood pressure and non-invasive blood pressure. Invasive blood pressure will be measured from radial artery cannulation, and non-invasive blood pressure will be measured by blood pressure cuff at Rt. upper arm. Thereafter, the difference of mean blood pressure between two values will be used for data analysis. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Seoul National University Hospital | Seoul | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 33527182 | Derived | Oh H, Choe SH, Kim YJ, Yoon HK, Lee HC, Park HP. Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial. J Clin Monit Comput. 2022 Apr;36(2):387-395. doi: 10.1007/s10877-021-00663-7. Epub 2021 Feb 1. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 1 minute after cannulation |