Not provided
Not provided
Not provided
Not provided
Not provided
due to other priorities
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| University Children's Hospital Basel | OTHER |
Not provided
Not provided
Not provided
This trial compares capnographic signals using a modified CO2/O2 Guedel airway with a CO2/O2 nasal cannula without and with oxygen supply in sedated children aged 4 - 24 months.
Sedation of pediatric patients is frequently jeopardized by respiratory adverse events such as central and/or obstructive apnea resulting in hypoxemia. Various factors such as patient comorbidities, medication and inconsistent physiologic monitoring are known to contribute to or facilitate adverse events during sedation. Therefore, monitoring of breathing by capnography is recommended and has become common standard e.g. by the use of a CO2/O2 nasal cannula.
However, capnography derived from CO2/O2 nasal cannulas may be impaired and these impairments are exaggerated in infants based on their physiologic characteristics (small tidal volumes, high respiratory rates).
To overcome these impairments, the investigators developed a modified CO2/O2 Guedel airway including a CO2 sampling port at the tip of the airway. In a previous study, significantly more accurate capnographic signals resulted compared with measurements derived from a nasal cannula when using a modified CO2/O2 Guedel airway in a model of a breathing 6-month-old manikin.
The aim of the study is to examine the accuracy of capnographic measurements of the modified CO2/O2 Guedel airway in comparison with measurements from a CO2/O2 nasal cannula in sedated children aged 4 - 24 months.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Nasal cannula / Guedel | Experimental | Record of capnography using a standard nasal cannula followed by use of a modified Guedel airway |
|
| Guedel / nasal cannula | Experimental | Record of capnography using a modified Guedel airway followed by use of a standard nasal cannula |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| modified Guedel airway | Device | Monitoring of breathing |
|
| Measure | Description | Time Frame |
|---|---|---|
| end-tidal carbon-dioxide concentration (etCO2) | Difference between capillary and maximum etCO2 sampled via a modified CO2/O2 Guedel airway versus a CO2/O2 nasal cannula | 90 seconds |
| Measure | Description | Time Frame |
|---|---|---|
| Change of end-tidal carbon-dioxide concentration (etCO2) according to different oxygen flows (O2) | Effect of O2 administration on etCO2 measurement | 90 seconds |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Thomas Erb, Prof. Dr. MD | UKBB | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Children´s Hospital | Basel | Canton of Basel-City | 4056 | Switzerland |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29757925 | Background | Moll J, Anagnostopoulou P, Frei FJ, Erb TO. A modified CO2/O2 Guedel airway improves capnographic accuracy compared with a CO2/O2 nasal cannula: An infant manikin study. Eur J Anaesthesiol. 2018 Aug;35(8):566-572. doi: 10.1097/EJA.0000000000000818. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001049 | Apnea |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
Not provided
Not provided
Prospective, randomized, single-blinded cross-over study
Not provided
Not provided
Not provided
Not provided
| D013568 | Pathological Conditions, Signs and Symptoms |