This is a randomized crossover trial to evaluate the effects of thoracic compression applied alone or in association with hyperinflation maneuver with the ventilator. In addition, the mobilized volume and peak expiratory flow resulting from both maneuvers will be evaluated.
Ventilator hyperinflation is widely used in hypersecretive patients. It consists of increasing alveolar ventilation by facilitating the coughing mechanism so that the secretions of the peripheral airways are mobilized into the central airways so that they can be removed by tracheal aspiration or cough. Thoracic compression consists of manually compressing the rib cage during expiration, in order to increase expiratory flow, mobilize and remove pulmonary secretions. A randomized crossover clinical trial was performed with 30 patients submitted to isolated compression or associated with ventilator hyperinflation, with a 6 hour interval. Patients were evaluated through compliance and resistance of the respiratory system.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Expiratory Rib Cage Compression | Active Comparator | Expiratory rib cage compression was performed in 6 sets of 6 cycles, with 1 cycle interval. Ventilatory mode and parameters were maintained. |
|
| Compression + Ventilator Hyperinflation | Active Comparator | Expiratory rib cage compression was performed in 6 sets of 6 cycles, with 1 cycle interval. Ventilator hyperinflation was performed by increasing the inspiratory pressure to every 5 cmH2O until the total pressure reached 40 cmH2O, remaining the same. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Expiratory Rib Cage Compression | Other | Compression was performed in 6 sets of 6 cycles, with 1 cycle interval. Ventilatory mode and parameters were maintained. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Static compliance of respiratory system | Compliance was assessed through the occlusion maneuver at the end of inspiration, considering tidal volume, plateau pressure and PEEP. Three measurements were taken at each moment, the mean being used. | Baseline (before), immediately after ventilator hyperinflation or rib cage compression and five minutes after aspiration |
| Total Resistance of respiratory system | The total resistance of the respiratory system was evaluated through the occlusion maneuver at the end of the inspiration, considering the resistive pressure, measured by the difference between the maximum plateau pressure. Three measurements were taken at each moment, the mean being used. | Baseline (before), immediately after ventilator hyperinflation or rib cage compression and five minutes after aspiration |
| Airway Resistance | The airway resistance was assessed by means of the occlusion maneuver at the end of the inspiration, considering the rapid fall of the pressure immediately after the occlusion, measured by the difference between the maximum pressure and P1. Three measurements were taken at each moment, the mean being used. | Baseline (before), immediately after ventilator hyperinflation or rib cage compression and five minutes after aspiration |
| Peak expiratory flow | The peak expiratory flow was evaluated through passive expiration, being considered the greatest value of the flow in the expiratory phase. | Baseline (before), immediately after ventilator hyperinflation or rib cage compression and five minutes after aspiration |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| LUCIANO M CHICAYBAN, MSc | Brazilian Institute of Higher Education of Censa | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001261 | Pulmonary Atelectasis |
| ID | Term |
|---|---|
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Compression + Ventilator Hyperinflation | Other | Mechanical ventilator hyperinflation was performed by increasing the inspiratory pressure to every 5 cmH2O until the total pressure reached 40 cmH2O, remaining the same. In Expiratory Rib Cage Compression associated with ventilator hyperinflation, thoracic compression maneuver was performed at the end of inspiration, at the exact moment of cycling. |
|