This study evaluates whether the addition of tetanizing burst therapy reduces the pain associated with ICD shocks
The implantable cardioverter defibrillator is a device designed to rescue patients from life-threatening arrhythmias by delivering a defibrillation shock to allow restoration of cardiac rhythm. These defibrillation shocks are extremely painful, owing to sudden rapid contraction of thoracic and abdominal skeletal muscle, which, in addition to the heart, are stimulated by the defibrillation shock. Tetanizing Burst Therapy is a novel electrical waveform which tetanizes skeletal muscle with a brief burst of stimulation prior to the ICD shock, thereby reducing muscular contraction due to the shock. This study is designed for those patients who are already undergoing ICD replacement.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Tetanizing Burst Therapy | Device | Tetanizing Burst Therapy tetanizes skeletal muscle with a brief burst of stimulation prior to ICD shock, thereby reducing muscular contraction due to the shock |
| Measure | Description | Time Frame |
|---|---|---|
| Less pain after TBT impulse with ICD shock compared to ICD shock alone | Each subject will receive 2 therapies in random order delivered 5 minutes apart:
| 5 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| The efficacy of tetanizing burst therapy in subjects undergoing ICD replacement as assessed by NRS verbal score | After each shock, a blinded assessor will ask the subject to provide an NRS verbal score between 1 and 10, where 1 is no pain and 10 is the worst pain imaginable. The percent change in the NRS score will be calculated for each subject along with the change in skeletal muscle force waveform |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jane Wilson | Contact | 8457218210 | janew@databean.com |
| Name | Affiliation | Role |
|---|---|---|
| Ronald Berger, MD | Johns Hopkins University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Johns Hopkins Hospital | Recruiting | Baltimore | Maryland | 21287 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 5 minutes |
| The safety of tetanizing burst therapy in subjects undergoing ICD replacement as assessed by adverse events | Incidence rates of all adverse events will be calculated and compared to event rates in the literature. They will also be analyzed by severity and relationship to the device and/or study procedures. | 7 days |
| The device performance of tetanizing burst therapy in subjects undergoing ICD replacement as assessed degree of muscle contraction (Rate of Force Development) | The force of contraction is recorded at the patient's left elbow with a myometer | 5 minutes |