Colonic transendoscopic enteral tubing (TET) is a novel, safe, convenient, and reliable way for fecal microbiota transplantation (FMT) and the whole-colon enema treatment. The aim of this study was to evaluate the methodology, efficiency, feasibility and safety of using transparent cap-assisted endoscopy for colon TET implantation.
Our previous article has reported the method of colon TET. However, the investigators found that it was difficult to find the cavity because of the concentration of intestinal folds caused by the tube pulling after insertion of TET. It is well known that transparent cap-assisted colonoscopy is easier to flatten the semilunar folds and improve mucosal exposure. Here the investigators test the hypothesis that using transparent cap-assisted colonoscopy significantly decreases the second cecal intubation time which not only improve work efficiency, but also saves patients' anesthesia time and cost. Thus, the investigators design a prospective multicenter, randomized controlled trial. The aim of this study was to evaluate the methodology, efficiency, feasibility and safety of using transparent cap-assisted endoscopy for colon TET implantation.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| non-transparent cap-assisted endoscopic intubation | Other | we do not use transparent cap-assisted endoscopic intubation. |
|
| transparent cap-assisted endoscopic intubation | Other | we use transparent cap-assisted endoscopic intubation in the second insertion. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| colonic transendoscopic enteral tubing | Procedure | The procedure colonic transendoscopic enteral tubing is as follows:The TET tube was inserted into the ileocecal junction through the endoscopy channel at the first time of the cecal intubation after examination and evaluation of the whole colon. Then, the colonoscope was removed from the colon while the TET tube was maintained at the ileocecal junction. Then the endoscopy was inserted into the ileocecum again for affixing the TET tube to cecum with titanium clips. |
| Measure | Description | Time Frame |
|---|---|---|
| The second cecal intubation time | Record the time of colonoscopy from the anus to the ileal flap in the second insertion. | one day |
| Measure | Description | Time Frame |
|---|---|---|
| Adverse events rate | Procedure-related and tube-related adverse events after procedure | All patients were followed up from date of intubation to one mouth after discharge |
| TET success rate | The success rate of of the TET procedure |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Faming Zhang, MD; PhD | Contact | 086-25-58509883 | fzhang@njmu.edu.cn |
| Name | Affiliation | Role |
|---|---|---|
| Faming Zhang, MD; PhD | Nanjing Medical University | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Fmt-Dt-N-27/1350 | Recruiting | Nanjing | Jiangsu | 210011 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27556065 | Result | Peng Z, Xiang J, He Z, Zhang T, Xu L, Cui B, Li P, Huang G, Ji G, Nie Y, Wu K, Fan D, Zhang F. Colonic transendoscopic enteral tubing: A novel way of transplanting fecal microbiota. Endosc Int Open. 2016 Jun;4(6):E610-3. doi: 10.1055/s-0042-105205. Epub 2016 Apr 28. | |
| 22228167 | Result | Westwood DA, Alexakis N, Connor SJ. Transparent cap-assisted colonoscopy versus standard adult colonoscopy: a systematic review and meta-analysis. Dis Colon Rectum. 2012 Feb;55(2):218-25. doi: 10.1097/DCR.0b013e31823461ef. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| one day |
| Maximum insertion pain score | Using numerical rating scale to evaluate maximum insertion pain score in non anesthesia. The digital grading method uses 0-10 to represent different levels of pain, with 0 as painless and 10 as severe. The classification standard of pain degree is: 0: no pain; 1-3: mild pain; 4-6: moderate pain; 7-10: severe pain. | one day |
| Retention time of tube | Retention time of colonic transendoscopic enteral tubing | three month |
| Tubing time | The tubing time is from advancement of the TET tube through the channel to the end of the tubing. | one day |
| Titanium clip fixation time | Record the time required for fixing a titanium clip. | one day |
| Medical Center for Digestive Diseases, The Second Affiliated Hospital of Nanjing Medical University | Recruiting | Nanjing | Jiangsu | 210011 | China |
|