Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss-of-resistance (LOR): when the needle/catheter tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. Epidural waveform analysis can be carried out through the tip of the needle or the catheter. In this randomized trial, the objective is to compare epidural waveform analysis through the needle (EWA-N) and through the catheter (EWA-C) for thoracic epidural blocks.
The epidural space is most commonly identified with loss-of-resistance (LOR). Though sensitive Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for LOR. When the needle (or catheter) is correctly positioned inside the epidural space, pressure measurement at its tip results in a pulsatile waveform synchronized with arterial pulsations Currently, there exist two different methods for EWA. Since local anesthetic (LA) is administered through the catheter, pressure transduction through its tip ensures that it is properly positioned inside the epidural space prior to LA injection. Alternately, EWA can be performed through the needle prior to blind advancement of the epidural catheter.
Thus, in this randomized trial, the aim is to compare epidural waveform analysis through the needle (EWA-N) and through the catheter (EWA-C) for thoracic epidural blocks. The hypothesis is that, compared to EWA-C, EWA-N will result in a shorter performance time.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| EWA through the needle | Experimental | EWA through the needle group, 5 mL of normal saline are injected through the epidural needle after the occurrence of LOR. The needle is subsequently connected to the pressure transducer (leveled with the heart) via the sterile, rigid extension tubing. A satisfactory endpoint is defined as the presence of waveforms synchronized with arterial pulsations. |
|
| EWA through the catheter | Experimental | EWA through the catheter group, the epidural catheter is advanced 5 cm beyond the needle tip after the occurrence of LOR. Subsequently, the operator injects 5 mL of normal saline through the catheter and the latter is connected to the pressure transducer via the sterile, rigid extension tubing. A satisfactory endpoint is defined as the presence of waveforms synchronized with arterial pulsations. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| EWA through the needle | Device | In the EWA-N group, 5 mL of normal saline are injected through the epidural needle after the occurrence of loss-of-resistance (LOR). The needle is connected to the pressure transducer. A satisfactory endpoint is defined as the presence of waveforms synchronized with arterial pulsations. In the absence of pulsatile waveforms, the operator injects an additional 2.5 mL-bolus of normal saline through the epidural needle and reconnects the latter to the pressure transducer. If no waveforms are detected after the second injection, the operator removes the needle and reattempts the epidural block at a different intervertebral level. A maximum of 3 levels is permitted: if waveforms are still absent at the third level, the operator simply accepts LOR as the technical endpoint. |
| Measure | Description | Time Frame |
|---|---|---|
| Performance time of block | temporal interval in minutes between skin infiltration and local anesthetic administration through the epidural catheter (after obtaining a satisfactory waveform either through the needle or through the catheter depending on randomized group assignment). | From skin infiltration until local anesthetic administration through the needle or catheter, up to 60 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of successful epidural block | bilateral block to ice in at least 2 dermatomes | 15 minutes after the administration of local anesthetic through the epidural catheter |
| Procedural pain during epidural block assessed by the numeric rating scale |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| De Q Tran, MD, FRCPC | McGill University Health Centre/Research Institute of the McGill University Health Centre | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital ClÃnico Universidad de Chile | Santiago | RM | Chile | |||
| Ramathibodi Hospital |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25642911 | Background | Tran DQ, Gonzalez AP, Bernucci F, Finlayson RJ. Confirmation of loss-of-resistance for epidural analgesia. Reg Anesth Pain Med. 2015 Mar-Apr;40(2):166-73. doi: 10.1097/AAP.0000000000000217. No abstract available. | |
| 435350 | Background | Sharrock NE. Recordings of, and an anatomical explanation for, false positive loss of resistance during lumbar extradural analgesia. Br J Anaesth. 1979 Mar;51(3):253-8. doi: 10.1093/bja/51.3.253. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Randomized trial
Not provided
Not provided
The outcome assessment will not be present during the performance of the epidural block and waveform analysis.
|
| EWA through the catheter | Device | In the EWA-C group, the epidural catheter is advanced 5 cm beyond the needle tip after the occurrence of LOR. Subsequently, the operator injects 5 mL of normal saline through the catheter and the latter is connected to the pressure transducer via the sterile, rigid extension tubing. A satisfactory endpoint is defined as the presence of waveforms. In the absence of pulsatile waveforms, the operator injects an additional 2.5 mL-bolus of saline through the catheter and reconnects the latter to the pressure transducer. If no waveforms are detected after the second injection are still absent at the third level, the operator simply accepts this position for catheter placement (intent-to-treat analysis). |
|
pain in the back of the patient, related to the performance of the epidural block, using a numeric rating scale from 0 to 10 points (0=no pain and 10= worst imaginable pain)
| From the performance of the epidural block until induction of general anesthesia, up to 2 hours |
| Postoperative pain related to surgical incision assessed by the numeric rating scale | pain at rest and upon deep breathing/coughing, measured using a numeric rating scale from 0 to 10 points ((0=no pain and 10= worst imaginable pain) | twice a day from the arrival at PACU or until catheter removal, up to 5 days |
| Local anesthetic consumption | amount of local anesthetic consumed | once a day from the arrival at PACU or until catheter removal, up to 5 days |
| Breakthrough opioid consumption (if required) | amount of opioids consumed | once a day from the arrival at PACU or until catheter removal, up to 5 days |
| Incidence of adverse events | side effects related to the performance of the epidural block (eg, dural/vascular puncture, paresthesia) or breakthrough opioids (nausea, vomiting, pruritus, somnolence, respiratory depression) | Once a day from catheter insertion until removal, up to 5 days |
| Bangkok |
| Thailand |
| 13327296 | Background | BONICA J. Continuous peridural block. Anesthesiology. 1956 Jul-Aug;17(4):626-30. No abstract available. |
| 14639154 | Background | Lirk P, Kolbitsch C, Putz G, Colvin J, Colvin HP, Lorenz I, Keller C, Kirchmair L, Rieder J, Moriggl B. Cervical and high thoracic ligamentum flavum frequently fails to fuse in the midline. Anesthesiology. 2003 Dec;99(6):1387-90. doi: 10.1097/00000542-200312000-00023. |
| 15041621 | Background | Lirk P, Moriggl B, Colvin J, Keller C, Kirchmair L, Rieder J, Kolbitsch C. The incidence of lumbar ligamentum flavum midline gaps. Anesth Analg. 2004 Apr;98(4):1178-1180. doi: 10.1213/01.ANE.0000101486.41355.35. |
| 937760 | Background | Chayen D, Nathan H, Chayen M. The psoas compartment block. Anesthesiology. 1976 Jul;45(1):95-9. doi: 10.1097/00000542-197607000-00019. No abstract available. |
| 517716 | Background | Eason MJ, Wyatt R. Paravertebral thoracic block-a reappraisal. Anaesthesia. 1979 Jul-Aug;34(7):638-42. doi: 10.1111/j.1365-2044.1979.tb06363.x. |
| 26469364 | Background | Leurcharusmee P, Arnuntasupakul V, Chora De La Garza D, Vijitpavan A, Ah-Kye S, Saelao A, Tiyaprasertkul W, Finlayson RJ, Tran DQ. Reliability of Waveform Analysis as an Adjunct to Loss of Resistance for Thoracic Epidural Blocks. Reg Anesth Pain Med. 2015 Nov-Dec;40(6):694-7. doi: 10.1097/AAP.0000000000000313. |
| 27035462 | Background | Tran DQ, Van Zundert TC, Aliste J, Engsusophon P, Finlayson RJ. Primary Failure of Thoracic Epidural Analgesia in Training Centers: The Invisible Elephant? Reg Anesth Pain Med. 2016 May-Jun;41(3):309-13. doi: 10.1097/AAP.0000000000000394. |
| 26894628 | Background | Arnuntasupakul V, Van Zundert TC, Vijitpavan A, Aliste J, Engsusophon P, Leurcharusmee P, Ah-Kye S, Finlayson RJ, Tran DQ. A Randomized Comparison Between Conventional and Waveform-Confirmed Loss of Resistance for Thoracic Epidural Blocks. Reg Anesth Pain Med. 2016 May-Jun;41(3):368-73. doi: 10.1097/AAP.0000000000000369. |
| 16301268 | Background | de Medicis E, Tetrault JP, Martin R, Robichaud R, Laroche L. A prospective comparative study of two indirect methods for confirming the localization of an epidural catheter for postoperative analgesia. Anesth Analg. 2005 Dec;101(6):1830-1833. doi: 10.1213/01.ANE.0000184130.73634.BE. |
| 17934163 | Background | de Medicis E, Pelletier J, Martin R, Loignon MJ, Tetrault JP, Laroche L. Technical report: optimal quantity of saline for epidural pressure waveform analysis. Can J Anaesth. 2007 Oct;54(10):818-21. doi: 10.1007/BF03021709. |
| 31092706 | Derived | Tangjitbampenbun A, Layera S, Arnuntasupakul V, Apinyachon W, Venegas K, Godoy J, Aliste J, Bravo D, Blanch A, Webar J, Saadawi M, Owen A, Finlayson RJ, Tran DQ. Randomized comparison between epidural waveform analysis through the needle versus the catheter for thoracic epidural blocks. Reg Anesth Pain Med. 2019 May 14:rapm-2019-100478. doi: 10.1136/rapm-2019-100478. Online ahead of print. |