A smaller caliber of intravenous cannulae decreases the number of thrombi and phlebitis and improves the duration of peripheral access. It also reduces the incidence of extravasation. 26G cannulae are easier to insert and reduce the number of attempts for cannulation. Safety cannulae are equivalent in terms of durability and ease of insertion, additionally providing a reduction in needle stick injury amongst healthcare professionals and patients.
The goal of this study is to reduce the number of peripheral line insertions and resulting complications in neonates.
The Investigators propose to compare 24G safety and 26G safety cannulae with non-safety 24G cannulae in infants < 32 weeks Gestation and < 1.5 kg weight in terms of length of stay of cannula, ease of insertion and rates of complications such as thrombosis, phlebitis and extravasation.
The Investigators will also evaluate the frequency of needle stick injury to staff and patients in the course of the study.
Peripheral venous cannulation is a common procedure on neonatal NICU. Insertion of peripheral cannulae in neonates is a painful and stressful procedure (5) and it is therefore desirable to minimize the number of procedures by increasing the survival time of each cannula. The incidence of phlebitis is variously described as 20 - 80% (2). Failure of venous access is often due to thrombi, phlebitis and extravasation. Mechanical phlebitis can be avoided by using the smallest gauge cannula capable of delivering the prescribed drug. (1) Mechanical phlebitis occurs where there is movement of a foreign object (cannula) within a vein causing friction and subsequent inflammation(3). Success rates for cannulation depend on a range of factors including the clinician's experience, gauge of cannula and infants weight as well as the condition of veins. Median survival of 24G Teflon intravenous cannulae was described as 40 hours in one study (4). There are few studies on the appropriate sizing of intravenous cannulae in children.
Flow rates for intravenous devise vary greatly depending on the manufacturer. Flow rates for 24G cannulae are 13 - 29 ml/min. The 26G cannulae achieve flow rates of 13 -19 ml/min which is adequate for use on NICU. The most commonly used devise on NICU SMH are 24G cannulae with a flow rates between13ml/min and 25 ml/min depending on manufacturer.
In this study the proposed non-safety 24 G cannula achieves a flow rate of 25 ml/min whereas the safety 24G and 26 G cannula achieve 22ml/ min and 15ml/min respectively.
Within the EU safety devices are mandatory since 2010 (6). Needle stick injuries during venepuncture pose a risk for healthcare professionals and other staff due to the transmission of blood borne pathogens such as Hepatitis B, Hepatitis C and HIV. This has cost implications for the NHS.
Safety cannulae in both 24 and 26 G have been trialed on the investigator's NICU in 2017 and are felt to be an important addition providing both safe and reliable cannulation. The design of the safety cannula is very similar to cannulae already used on the unit and handling does not require change in practice.
Due to the winged design of both safety and non-safety cannulae fixation of the line post insertion can be standardized.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| IVCannulation 24G non-safety cannula | Active Comparator | Peripheral Intravenous cannulation using 24G non-safety cannula |
|
| IVCannulation 26G safety cannula | Active Comparator | Peripheral Intravenous cannulation using 26G safety cannula |
|
| IVCannulation 24G safety cannula | Active Comparator | Peripheral Intravenous cannulation using 24G safety cannula |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| IVcannulation | Device | Peripheral venous cannulation is a common procedure on neonatal NICU, especially in preterm infants |
|
| Measure | Description | Time Frame |
|---|---|---|
| length of stay of cannula | How long the cannula continues to work | Maximum of a week |
| Measure | Description | Time Frame |
|---|---|---|
| ease of insertion | How easy or difficult staff find the cannula to insert | Maximum of a week |
| rates of complications | thrombosis, phlebitis and extravasation |
| Measure | Description | Time Frame |
|---|---|---|
| frequency of needle stick injury | To staff and patients | At time of Insertion |
Inclusion Criteria:
Exclusion Criteria:
.Neonates with severe skin conditions such as Epidermolysis Bullosa.
.Patients considered for reorientation of care or palliative care. .Infants previously recruited to the study who had a total of 3 episodes of randomization.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Anna Pawleletz | Manchester University Foundation Trust, Manchester | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Neonatal Intensive Care Unit, St Mary's Hospital | Manchester | M13 9WL | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 12190760 | Background | Panadero A, Iohom G, Taj J, Mackay N, Shorten G. A dedicated intravenous cannula for postoperative use effect on incidence and severity of phlebitis. Anaesthesia. 2002 Sep;57(9):921-5. doi: 10.1046/j.1365-2044.2002.02786.x. | |
| 19444022 | Background | Stokowski G, Steele D, Wilson D. The use of ultrasound to improve practice and reduce complication rates in peripherally inserted central catheter insertions: final report of investigation. J Infus Nurs. 2009 May-Jun;32(3):145-55. doi: 10.1097/NAN.0b013e3181a1a98f. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D047928 | Premature Birth |
| ID | Term |
|---|---|
| D007752 | Obstetric Labor, Premature |
| D007744 | Obstetric Labor Complications |
| D011248 | Pregnancy Complications |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
Not provided
Not provided
Once consent is obtained, patients will be randomized to either 24G non-safety cannula, 24G safety or 26G safety cannula. Each patient can enter the study a maximum of three times providing 90 episodes of cannulation.
Not provided
Not provided
Not provided
Not provided
|
| Average of a week |
| 12923741 | Background | Gupta P, Rai R, Basu S, Faridi MM. Life span of peripheral intravenous cannula in a neonatal intensive care unit of a developing country. J Pediatr Nurs. 2003 Aug;18(4):287-92. doi: 10.1016/s0882-5963(03)00052-6. |
| D000091642 | Urogenital Diseases |